HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 41

Hp storageworks fabric os 6.2.1 release notes (5697-0275, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Occasionally an LD port gets into a lock up state that causes port-
GetVCCredits get failed and the ISL segments with LD incom-
plete, although portcfgshow shows both sides of ISL config are the
same.
EE monitor counters may not get updated after performing switch-
disable/switchenable or reboot.
Static routing does not affect dynamic routes with DLS ON on supported
platforms.
The gzoneinfo.htm page returns empty data when CLI actually
shows defined/eff cfg zone info for fabric.
Third-party storage center application does not survive in an FCIP
network with 1% packet loss and 100 ms network latency.
Traffic isolation failover policy reverts back to disabled from enabled
after changing the port membership list.
Hareboot on 400 MP Router FC Fast Write enabled switch causes
the system to panic with Oops: kernel access of bad area,
sig: 11 [#1].
Fabric Mode TT displays redundant flows with different values for the
same SID/DID pair on the core switches when there are redundant
trunk groups to the same edge domain.
DLS ON does not rebalance when ISLs to a different switch are re-
moved on HP StorageWorks DC SAN Backbone Director and HP
StorageWorks 8/80 SAN Switch.
On an HP StorageWorks 8/80 SAN Switch, the system status LED
does not flash amber/green when a power supply is faulted.
User with admin role in some AD is able to add another user with
admin role in AD as ALL.
Reset to default button is grayed out always in SCSI vs. IP traffic setup
window.
USB Admin is not in sync with CLI when launched . It shows the correct
info only when we click refresh button.
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Reset with portcfgdefault/port-
cfgqos.
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Retrieve all EE monitors from the
FLASH by issuing perfcfgrestore.
All EE monitor counters will be prop-
erly updated.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Do any other HTTP post operation
from DCFM and then you see both
the old data and the newly pushed
zone info. Rebooting the switch
sometimes helps.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Perform switchdisable and
switchenable to force a rebalance
of the routes.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
HP StorageWorks Fabric OS 6.2.1 release notes
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents