Fabric OS 6.2.1 fixes
Table 16
lists defects closed in the Fabric OS 6.2.1 firmware release. In addition to including all fixes
from previous 6.2.0x releases, 6.2.1 contains all fixes included in the 5.3.2b, 6.0.1a, 6.1.1d, and
6.1.2a releases. These fixes are identified in
Table 16 Fabric OS 6.2.1 closed defects
Sshd allows admin login to execute root-level Linux commands, but
admin CLI commands fail with a command not found error.
On rare occasions, an extra RSCN is delivered when HA failover is
performed before the name server is in sync.
Firmware is not enforcing a mandatory switch disable before configur-
ing the backbone fabric ID.
Common Area Loader Daemon (CALD) shared memory is not released,
leading to high CPU load and inability to run many of the CLI com-
mands; causes no space left on device error.
In mixed Fabric OS and M-EOSc fabric in interopmode 2, with more
than 500 devices, nameserver database counts do not match. This issue
does not exist with M-EOSn based switches in a mixed fabric.
Toggling the N_Port could cause the F_Port to get disabled, leading
to the crypto LUN getting stuck in a Not ready (LUN rediscovery)
state with HP StorageWorks Encryption SAN Switch in Access Gateway
mode.
A switch having a zone object with an extra ";" or -p flag for a zone
create does not perform an error check for alphanumeric characters,
which can trigger loss of zone configuration after a firmware upgrade,
or can cause a switch panic after the cfgenable command.
In Access Gateway mode, the FDMI database does not show proper
information after disabling the port connected to an HBA. Brocade_Soft-
ware Identity instance for the remaining node is missing in Brocade
SMIA.
During a stress test with switchdisable/switchenable of all
switches in a fabric, we observed both verify failure and a switch
panic in the RTE module.
Table
Closed defect summary
HP StorageWorks Fabric OS 6.2.1 release notes
16.
Fixed in Fabric OS 6.2.1
Workaround prior to update: A
workaround to facilitate execution of
admin level CLI commands using ssh,
is to use syntax similar to ssh -l
admin 192.168.1.12 rbash
--login -c switchshow. Or, if
a command is needed that works on
both older (correctly operating) Fabric
OS and the newer/affected Fabric
OS: ssh -l admin
192.168.1.12 switchshow ||
rbash --login -c
switchshow.
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Workaround prior to update: Run
hafailover prior to the upgrade.
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Solution