HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 35

Hp storageworks fabric os 6.2.1 release notes (5697-0275, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

3.
Perform a configdownload to the new GL node of a previously uploaded configuration
file for the EG from an old GL Node.
4.
For any containers hosted on the failed GL node, issue cryptocfg --replace to
change the WWN association of containers from failed GL node to the new GL node.
Initial setup of encrypted LUNs
IMPORTANT:
While performing first-time encryption to a LUN with more than one initiator active at the time, rekey
operations slow to a standstill. Define LUNs for a single initiator at a time to avoid this occurrence.
NOTE:
When configuring multipath LUNs, care should be taken to add LUN 0 on all of the paths, subject to
the following considerations:
If LUN 0 presented by the back-end target is a controller LUN (not a disk LUN; that is, not visible
in the discoverLUN output), add LUN 0 to the container as a clear text LUN. Make sure all of
the paths have this LUN 0 added for MPIO operation (EVA configuration, for example).
If LUN 0 presented by the back-end target is a disk LUN, LUN 0 can be added to the container
either as clear text or encrypted (MSA configuration, for example).
For HP-UX, LUN 0 can appear as 0x0 or 0x400, but both of them are LUN 0 only and should be
treated alike.
Fabric OS 6.2.0 fixes
Table 8
lists defects closed in the Fabric OS 6.2.0 firmware release.
Table 8 Fabric OS 6.2.0 closed defects
Closed defect summary
Add Member button is disabled while creating a new TI Zone when
the switch is in VF mode.
Under stress testing, cfgsave takes a long time and fails to propagate
on 64 VE-VE FCIP tunnel 33 switch core-edge topology running I/O.
Adding a B-series switch with conflicting domain ID into an EOS fabric
may cause another switch to segment.
Solution
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Add Other Port button can be used to
add ports. This is available in the
ADD TI Zone window.
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Wait until fabric is not saturated to
push configs around.
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Check the domain ID before adding
a switch to any fabric.
HP StorageWorks Fabric OS 6.2.1 release notes
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents