HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 43

Hp storageworks fabric os 6.2.1 release notes (5697-0275, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Security Violation Console Message reported on nonexistent port# on
an HP StorageWorks 4/64 SAN Switch (interopmode 2) with no se-
curity policy set.
Fabric OS does not send RSCN for CUP disable / enable in NI
mode 2.
Channel ack_1 to Control Unit ACC is being F_RJT'd after successful
RNID.
F_RJT not returned for unroutable class 2 PLOGI.
Missing CE DE status.
FMS does not retry status after FICON channel returns LBY for Device
End.
FICON CUP reports incorrect Director Size Code in Basic Sense and
Sense ID data for HP StorageWorks 8/40 and 8/80 SAN switches.
Portcfgspeed command on 8G FC platforms are accepting invalid
port speed = 5.
XRC Emulation allows FICON Disk Control Unit paths to be activated
with DPR Mode.
FMS stuck busy condition caused host *MASTER* START PENDING
upon bringing switch online to mainframe operating system.
CP card of HP StorageWorks 4/256 SAN Director is set to FAULTY
(51).
HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN switches: when
normal fan activity is interrupted, the high RPM fan rate cycle time
takes 1 hour.
RLS request from FICON host receives LS_RJT 031F in Interopmode 2.
FMS Mode enable failed due to insufficient frame filtering resources
on some ports.
HP StorageWorks DC SAN Backbone Director blades fault after reset-
ting a server with 32 HBAs.
Fast Write configuration not properly installed after repeated, back-to-
back cable pull and re-inserts.
Out of Order frames delivered to HP StorageWorks DC SAN Backbone
Director via FICON channel from HP StorageWorks 8/40 SAN Switch
attached to a storage device (DASD).
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Do not use port 0 for an ISL.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Do not provide a value of 5 to the
portcfgspeed command. Speed
will be set to 8. If that is not desired,
resubmit the command with the proper
port speed.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Power cycle the slot. Set port speed
to anything other than autonegotiate.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
HP StorageWorks Fabric OS 6.2.1 release notes
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents