Fabric OS 6.2.0c fixes
Table 11
lists defects closed in the Fabric OS 6.2.0c firmware release.
Table 11 Fabric OS 6.2.0c closed defects
Closed defect summary
When port locked as G_Port, 8-Gb device may connect at 4 Gb rather
than 8 Gb.
Occasionally during the firmware upgrade process, the 1250 processor
is still rebooting when FCR routes are being processed, which results
in missing FCR routes and an inability to route traffic across VEX ports.
This leads to I/O running through VEX ports to be dropped after firm-
ware upgrade.
VI to PT routes are deleted following portdisable/portenable
on HP StorageWorks SAN Director 48 Port FC blade.
RSCN transmitted by the switch did not transmit all the port IDs in the
payload after HPF key on or off.
When Top Talkers is enabled with frame redirection, HP StorageWorks
DC SAN Director can crash causing data encryption backup to fail.
Stable working encryption group experienced a split after successful
I/O test run, and encryption group leader got a comm error.
Encryption group does not automatically recover after encountering a
split group condition.
When performing first time encryption to a LUN with more than one
initiator active at the same time, rekey operations slow significantly,
causing host applications to experience delays in the completion of
I/O requests.
Software verify errors and IFCCs occurred during supportsave on
HP StorageWorks DC SAN Director and on HP StorageWorks DC04
SAN Director
Chassisinfo is not provided with snmpv1 without adding and configur-
ing an snmpv3 user. The first 6 objects in the system MIB are missing,
corresponding to the Error: no such object entries in the Hi-
Track system table.
VIs/VTs may disappear when rebooting the HP StorageWorks Encryp-
tion SAN Switch that has all physical connections to targets and initi-
ators.
48
Solution
Workaround prior to upgrade: Lock
the switch port to 8 Gb, rather than
rely on auto-negotiation.
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Workaround prior to upgrade: Do not
enable Top Talkers concurrently with
functionality that is using frame
redirection.
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Workaround prior to upgrade: 1.
Disable the target ports. 2. Remove
one initiator from the container. 3.
Start the rekey operation. 4. Add the
initiator back.
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c