Table 6.2 System-Level Field Troubleshooting - Fujitsu MAN3367FC - Enterprise 36.7 GB Hard Drive Product/Maintenance Manual

Disk drives
Table of Contents

Advertisement

Diagnostics and Maintenance
Item
AC and DC power level
Electrical noise
Drive selection address
System cables
System diagnostic test
Intermittent or nonfatal errors
6-14
Table 6.2
System-level field troubleshooting
Check that the DC voltage is within the specified range (±5%).
Check that the +5 VDC value (pin of the interface connector) is 4.75 to
5.25 VDC.
Check that the +12 VDC supply (pin of the interface connector of disk
drive) is 11.4 to 12.6 VDC.
Make sure the maximum ripple peak-to-peak value of +5 VDC is within
250 mV and +12 VDC is within 250 mV.
Check that the disk drive selection address is set correctly.
Check that all system cables are connected correctly.
When possible, execute the system level diagnostic routine as explained
in the host computer manual. This gives a detailed report of a possible
fault.
Check the AC voltage from the power supply. Check the DC voltage
level at the power connector for the disk drive.
If the AC voltage level is abnormal or there is a lot of electrical noise,
notify the user of the error.
If the DC voltage level is unstable, replace the power supply unit.
If possible, replace the disk drive. If replacing the disk drive does not
eliminate the error, the removed disk drive is probably not faulty. To
continue error analysis, refer to the hardware and software manuals
supplied with the system.
Recommended work
C141-E133-02EN