Fujitsu MAN3367FC - Enterprise 36.7 GB Hard Drive Product/Maintenance Manual page 80

Disk drives
Table of Contents

Advertisement

Installation
Notes:
1.
The user can arbitrarily specify the following parameters according to the system
requirements:
ARRE
AWRE
TB
PER
2.
The user also can arbitrarily specify parameters other than the above. However, it is
recommended to use the default setting in normal operations.
(2)
Disconnection/reconnection parameters (page code = 2)
The following parameters are used to optimize the start timing of reconnection processing to transfer
data on the loop at a read (READ or READ EXTENDED command) or write operation (WRITE,
WRITE EXTENDED, or WRITE AND VERIFY command) of the disk. Refer to Chapter 2 of Fibre
Channel Interface Specifications for further details.
• Buffer full ratio
• Buffer empty ratio
Notes:
1.
In a system without the disconnection function, these parameters need not be specified.
2.
Determine the parameter values in consideration of the following performance factors of the
system:
Time required for reconnection processing
Average amount of processing data specified with a command
Refer to Chapter 2 of Fibre Channel Interface Specifications for how to obtain the rough
calculation values for the parameter values to be set. It is recommended to evaluate the
validity of the specified values by measuring performance in an operation status under the
average system load requirements.