The IDD does not reply to the loop for up to 2 seconds after the initial self-diagnostics is started.
After that, the IDD can accept the I/O operation request correctly, but the received command, except
the executable commands under the not ready state (such as INQUIRY, START/STOP UNIT), is
terminated with the CHECK CONDITION status (NOT READY [=2]/logical unit not ready [=04-
00]) during the interval from the spindle motor becomes stable to the IDD becomes ready. The
executable command under the not ready state is executed in parallel with the initial self-diagnostics,
or is queued by the command queuing feature and is executed after completion of the initial self-
diagnostics. When the command that comes under the exception condition of the command queuing
is issued at that time, the IDD posts the BUSY status for the command. When the error is detected
during the initial self-diagnostics, the CHECK CONDITION status is posted for all commands that
were stacked during the initial self-diagnostics. For the command execution condition, refer to
Section 1.4 and Subsection 1.7.4 in Fibre Channel Interface Specifications.
(2)
Online self-diagnostics (SEND DIAGNOSTIC command)
The INIT can make the IDD execute self-diagnostics by issuing the SEND DIAGNOSTIC command.
The INIT specifies the execution of self-diagnostics by setting 1 for the SelfTest bit on the CDB in the
SEND DIAGNOSTIC command and specifies the test contents with the UnitOfl bit.
When the UnitOfl bit on the CDB is set to 0, the IDD executes the hardware function test only once.
When UnitOfl bit is set to 1, the IDD executes the hardware function test, seek (positioning) test, and
data write/read test for the Internal test space only once.
a. Error recovery during self-diagnostics
During the self-diagnostics specified by the SEND DIAGNOSTIC command, when the
recoverable error is detected during the seek or the write/read test, the IDD performs the error
recovery according to the MODE SELECT parameter value (read/write error recovery parameter,
additional error recovery parameter) which the INIT specifies at the time of issuing the SEND
DIAGNOSTIC command.
PER
0
1
b. Reporting result of self-diagnostics and error indication
When all specified self-diagnostics terminate normally, the IDD posts the GOOD status for the
SEND DIAGNOSTIC command.
When an error is detected in the self-diagnostics, the IDD terminates the SEND DIAGNOSTIC
command with the CHECK CONDITION status. At this time only when an error is detected in
the hardware function test, the IDD sends the Fault LED Out signal to the interface connector.
C141-E133-02EN
Operation of self-diagnostics
The self-diagnostics continues when the error is recovered. The self-
diagnostics terminates normally so far as the unrecoverable error is not
detected.
The self-diagnostics continues when the error is recovered. If the
unrecoverable error is not detected, the consecutive tests are executed till last
test but the self-diagnostics terminates with error. The error information
indicates that of the last recovered error.
6.1 Diagnostics
6-3