Table 5
Levels of protection against power failures
MSA power supplies connected to...
Two separate power sources
Two UPSs
Two separate power sources
WARNING!
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
Unplug the power cord from the power supply to remove power to the equipment.
Route the power cord so that it is not likely to be walked on or pinched by items placed against
it. Pay particular attention to the plug, electrical outlet, and the point where the cord is attached
to the MSA.
48
Installation procedures—All deployments
To reduce the risk of electric shock or damage to the equipment:
Provide this level of protection...
Protects you from downtime when one of the MSA power
supplies fails.
Protects you from data loss when one of your power sources
fails, due to a pulled cable or tripped breaker.
The remaining power source can power the MSA until the failed
power source is restored or relocated. Depending on the cause
and duration of the power outage, you can use this time to
properly shut down your storage sub-system.
Protects you from downtime when one of the MSA power
supplies fails.
Protects you from data loss when one or both of your power
sources fails, due to a pulled cable, tripped breaker, or
local power outage.
The remaining power source or the UPS will power the MSA
until power is restored to the source. Depending on the cause
and duration of the power outage, you can use this time to
properly shut down your storage sub-system.