WARNING!
The leveling jacks on the rack are extended to the floor.
The full weight of the rack rests on the leveling jacks.
The stabilizing feet are attached to the rack if it is a single-rack installation.
The racks are coupled together in multiple-rack installations.
Only one component in a rack is extended at a time. A rack may become unstable if more than
one component is extended.
Use the following instructions to install the MSA and its storage enclosures:
1.
Use the provided rack template as a guide to indicate where to place the rails for the
component:
a. With the front of the template and the rack facing you, align the lower edge of the template
with the bottom of the rack (or the top of the previous rack component.)
b. After verifying that the template is level, push the template tabs into the rack holes to hold the
template in place.
c. Use a pencil to mark the required location of the scissor-like locking latches on the rails, as
indicated by the template.
d. Repeat these steps to mark the back of the rack, using the information on the back of the
template as a guide.
2.
If the holes in the rack uprights are round instead of square, remove the standard pins from the
rails and replace them with the round-hold pins provided with the rail kit.
WARNING!
to replace them with the pins for round-hole racks.
32
Installation procedures—All deployments
To reduce the risk of personal injury or damage to the equipment, be sure that:
The pins in the rails are load bearing. Do not remove the standard pins except
15420