10. Replace the cover. Go to "Completing the installation" on page 22.

Installing an IBM Remote Supervisor Adapter II SlimLine

The optional IBM Remote Supervisor Adapter II SlimLine must be installed in its
dedicated connector on the system board. See the illustration on page 22 for the
location of the connector on the system board. The Remote Supervisor Adapter II
SlimLine is not cabled to the system board.
Complete the following steps to install the Remote Supervisor Adapter II SlimLine:
1. Read the safety information beginning on page vii, and "Installation guidelines"
2. Turn off the server and peripheral devices, and disconnect the power cords and
3. Assemble the Remote Supervisor Adapter II SlimLine and Interposer card:
20
IBM xSeries 236 Type 8841: Installation Guide
Adapter guide
5. See the documentation that comes with the adapter for any cabling instructions
and information about jumper or switch settings.
Attention:
Incomplete insertion might cause damage to the system board or
the adapter.
6. Press the adapter firmly into the expansion slot.
7. Close the adapter-retention latch and if necessary, the adapter-retention clip.
Important: Power cannot be provided to the adapter slot if the latch is not
lowered into place.
8. Connect any needed cables to the adapter.
Note: See the documentation that comes with the operating system for
information about enabling a hot-plug PCI-X slot.
9. If you have other options to install or remove, do so now.
on page 7.
all external cables. Remove the cover and air baffle assembly.