10-15. Adjusting the work clamp lift amount

The maximum lift amount for the work clamp is 30 mm above the top of the needle plate.
5018Q
1. Turn on the air, and depress the work clamp switch (1) to raise the work clamp (2).
2. Loosen the two bolts (4) of the work clamp arm lever (3), and move the work clamp arm lever (3) up or down to adjust.

10-16. Adjusting the air pressure

Lift up the handle (2) of the regulator (1) and then turn it to
adjust the air pressure to 0.5 MPa.
After adjustment is complete, push the handle (2)
downward to lock it.
If water has collected in the bottle of the regulator (1), turn
the drain cock (3) in the direction indicated by an arrow to
drain the water.
NOTE:
Open the air cock (4) slowly.
1912B
BAS-326G PS
10. STANDARD ADJUSTMENTS
Max. 30mm
2165B
64