A
A. Standard rear offset exhaust installation
B. Rear exhaust installation to left or right side
Z
c. Bottom exhaust installation
D. Over-the-top installation (also available with one
offset elbow)
NOTE: The following kits for alternate installations are available
for purchase. For further information, please call
1-800-4-MY-HOME
® (1-800-469-4663).
Rear exhaust installation to left or right side:
Part Number 8212504
Bottom exhaust installation:
Part Number 8212503
Over-the-top
installation:
Part Number 26-49900
Special provisions
for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
/-
Determine
vent path
Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest number of elbows and
turns.
When using elbows or making turns, allow as much room as
possible,
Bend vent gradually to avoid kinking,
Use the fewest 90 ° turns possible.
Determine
vent length and elbows
needed for best
drying performance
Use the following Vent system chart to determine type of vent
material and hood combinations
acceptable to use,
NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.
Vent system chart
NOTE: Bottom exhaust performance
is equivalent to adding two
elbows. To determine maximum exhaust length, add two elbows
to the chart.
NOTE: Performance of rear exhaust to either side of the dryer is
equivalent to adding one elbow. To determine maximum exhaust
length, add one elbow to the chart.
Number of
Type of
Box or
Angled
90 ° turns
vent
Louvered
hoods
or elbows
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
Flexible metal
36 ft (11 m)
28 ft (8.5 m)
1
Rigid metal
54 ft (16,5 m)
48 ft (14.6 m)
Flexible metal
31 ft (9.4 m)
23 ft (7 m)
2
Rigid metal
44 ft (13.4 m)
38 ft (11.6 m)
Flexible metal
27 ft (8.2 m)
19 ft (5.8 m)
3
Rigid metal
35 ft (10.7 m)
29 ft (8.8 m)
Flexible metal
25 ft (7.6 m)
17 ft (5.2 m)
4
Rigid metal
27 ft (8.2 m)
21 ft (6.4 m)
Flexible metal
23 ft (7 m)
15 ft (4.6 m)