Error Symptoms - IBM 8836 - Eserver xSeries 306 Maintenance And Troubleshooting Manual

Hardware maintenance manual
Hide thumbs Also See for 8836 - Eserver xSeries 306:
Table of Contents

Advertisement

Error symptoms

You can use the error symptom table to find solutions to problems that have definite
symptoms.
If you cannot find the problem in the error symptom charts, go to "Starting the
diagnostic programs and viewing the test log" on page 21 to test the server.
If you have just added new software or a new option and the server is not working,
use the following procedures before using the error symptom charts:
v Remove the software or device that you just added.
v Run the diagnostic tests to determine whether the server is running correctly.
v Reinstall the new software or new device.
In the following table, if the entry in the FRU/action column is a suggested action,
perform that action; if it is the name of a component, reseat the component and
replace it if necessary. The most likely cause of the symptom is listed first.
Note: See Chapter 7, "Parts listing xSeries 306 Type 1878, 8489 and 8836," on page 75 to determine which
components are replaceable by the customer, and which components must be replaced by a field service technician.
Symptom
CD-ROM drive is not
recognized.
Note: See Chapter 7, "Parts listing xSeries 306 Type 1878, 8489 and 8836," on page 75 to determine which
components are replaceable by the customer, and which components must be replaced by a field service technician.
Symptom
The SCSI expansion enclosure
used to work but does not work
now.
Note: See Chapter 7, "Parts listing xSeries 306 Type 1878, 8489 and 8836," on page 75 to determine which
components are replaceable by the customer, and which components must be replaced by a field service technician.
Symptom
Not all drives are recognized by
the hard disk drive diagnostic
test (Fixed Disk test).
62
xSeries 306 Type 1878, 8489 and 8836: Hardware Maintenance Manual and Troubleshooting Guide
CD-ROM drive problems
FRU/action
1. Make sure that:
v
The IDE channel to which the CD-ROM drive is attached (primary or
secondary) is enabled in the Configuration/Setup Utility program.
v All cables and jumpers are installed correctly.
v The correct device driver is installed for the CD-ROM drive.
2. Run CD-ROM drive diagnostics.
3. CD-ROM drive.
Expansion enclosure problems
FRU/action
1. Make sure that:
v The cables for all external SCSI options are connected correctly.
v The last option in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
v Any external SCSI option is turned on. You must turn on an external SCSI
option before turning on the server.
2. For more information, see the SCSI expansion enclosure documentation.
Hard disk drive problems
FRU/action
1. Remove the first drive not recognized and try the hard disk drive
diagnostic test again.
2. If the remaining drives are recognized, replace the drive you removed with a
new one.