Features and specifications

The following information is a summary of the features and specifications of the
xSeries 306 server. Depending on your server model, some features might not be
available, or some specifications might not apply.
Table 1. Features and specifications
Microprocessor:
®
v One Intel
Pentium
4 1024 KB
(minimum) Level-2 cache and
MMX
(MMX2) technology
Note: Use the Configuration/Setup
Utility program to determine the type
and speed of the microprocessor in
your server.
Memory:
v Minimum: 512 MB
v Maximum: 4 GB
v Type: PC2700/3200,
266 MHz, ECC, SDRAM, registered
DIMMs only
v Slots: Four dual inline
Drives:
v Diskette: 1.44 MB
v CD-ROM: IDE
Expansion bays:
v Two 3.5-inch slim-high bays for
hard disk drives
Expansion slots:
v Two 66 MHz/64-bit PCI-X slots (one
low profile half-length, one
full-height three-quarter-length)
Video controller:
v ATI Radeon 7000M IGP video on
system board
v Compatible with SVGA and VGA
v 16 MB DDR-SDRAM video memory
Power supply:
v 300 watt (110 or 220 V ac
auto-sensing)
Size:
v Height: 43 mm (1.75 inches, 1 U)
v
Depth: 508 mm (20 inches)
v Width: 430 mm (16.69 inches)
v Maximum weight: 12.7 kg (28 lb)
depending on your configuration
Integrated functions:
v Two 1000Base-T, 100Base-T,
10Base-T (dual) Ethernet
controllers on the system board
®
with Wake on LAN
support
v Serial port
v Four USB ports (two on front and
two on rear of server)
v Keyboard port
v Mouse port
Hard disk controller
v Simple swap Serial ATA controller
with integrated RAID
v Ultra320 SCSI controller with
integrated RAID (SCSI models)
Acoustical noise emissions:
v Sound power, idling: 6.5 bel
maximum
v Sound power, operating: 6.5 bel
maximum
Environment:
v Air temperature:
– Server on: 10° to 35°C (50.0°
to 95.0°F); altitude: 0 to 914 m
(2998.7 ft)
– Server off: -40° to 60°C
(-104° to 140°F); maximum
altitude: 2133 m (6998.0 ft)
v Humidity:
– Server on: 8% to 80%
– Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour:
v Minimum configuration: 307 Btu (90
watts)
v Maximum configuration: 850 Btu
(250 watts)
Electrical input:
v Sine-wave input (47-63 Hz) required
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.20 kVA
– Maximum: 0.45 kVA
Notes:
1. Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
2. These levels were measured in
controlled acoustical environments
according to the procedures
specified by the American National
Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296. Actual
sound-pressure levels in a given
location might exceed the average
values stated because of room
reflections and other nearby noise
sources. The declared sound-power
levels indicate an upper limit, below
which a large number of computers
will operate.
Chapter 1. General information