Notes:
1. The server supports six replaceable voltage regulator modules (VRMs).
2. The server supports a maximum of three power supplies.
3. See "Level 2 Light Path troubleshooting" on page 21 for a detailed description of
these LEDs and how to use them to resolve problems.

Remind button

You can use the Remind button to place the Fault light on the front panel into the
remind mode (blinks every 2 seconds). By pressing the button, you acknowledge
the failure but indicate that you are not taking immediate action. If a new failure
occurs, the Fault light turns on again.
The Fault light stays in remind mode until one of the following conditions occurs:
v All known problems are resolved
v The system is restarted
v A new problem occurs
You can use the Remind button to delay server maintenance until a later time. In
this way, the light will indicate any subsequent error. If the light is still lit from the
first error, it is unable to indicate subsequent errors.
Power supply number 1 failure
Power supply number 3 failure
Nonredundant power mode
Microprocessor failure
Memory failure
Fan failure
Remote Supervisor Adapter failure
See event log or Remote Supervisor Adapter log for
non-optimal condition information
69