Summary of Contents for Intel SR1475NH1 - Server Platform - 0 MB RAM
Page 1
® Intel Server Board SE7230NH1-E and ® Intel Server Platform SR1475NH1-E User’s Guide Intel Order Number D23185-005...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Intel Server Board SE7230NH1-E User Guide. For the latest version of this manual, refer to http://support.intel.com/support/motherboards/server/SE7230NH1-E/.
Processor, memory DIMMs, hard drive, floppy drive, CD-ROM or DVD-ROM drive, RAID controller, operating system. For information about which accessories, memory, processors, and third-party hardware have been tested and can be used with your board, and for ordering information for Intel products, see http://support.intel.com/support/motherboards/server/SE7230NH1-E/ compat.htm.
Page 5
For firmware and BIOS updates, or BIOS Firmware Updates recovery For diagnostics test software Diagnostics See also the Intel® Server Deployment Toolkit CD that came with your server board Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Page 6
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm.
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® ® viii Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Removing DIMMs ........................15 Installing or Replacing the Processor ..................15 Installing the Processor ......................15 Installing the Active Heat Sink ....................18 Installing the Passive Heat Sink ....................19 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Page 10
Zielbenutzer der Anwendung ....................43 Standortauswahl ........................43 Handhabung von Geräten ......................43 Warnhinweise für den Systemzugang ..................45 Elektrostatische Entladungen (ESD) ..................46 Andere Gefahren ........................47 Français ..........................48 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Page 11
Europe (CE Declaration of Conformity) ..................68 Taiwan Declaration of Conformity (BSMI) ................68 Korean Compliance (RRL) ......................69 ® D Intel Server Issue Report Form ................ 71 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Page 12
® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Figure 10. Closing the Load Plate and Socket Lever ............... 18 Figure 11. Installing the Active Heat Sink................. 19 Figure 12. Installing the Passive Heat Sink................20 Figure 13. Removing the Battery....................22 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide xiii...
Page 14
® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Server Board Features ® This chapter briefly describes the main features of the Intel Server Board SE7230NH1- E. This chapter provides drawings of the product, a list of the server board features, and diagrams showing the location of important components and connections on the server board.
Pentium D, Pentium 4 or Celeron processor in the LGA775 package • ® Capable of 1066 MT/s on system bus when using the Intel ® Pentium 4 Processor Extreme Edition supporting Hyper- Threading Technology • Supports Intel® Dual Core Architecture •...
Page 19
• Segment A - Two PCI 32-bit/33-MHz 3.3V Universal connectors supporting full length PCI add-in cards (Adapters which support 5V only are not supported) and one embedded Intel® 10/100/ 1000 82541PI gigabit Ethernet Controller (Supports PCI Specification, Rev 2.3) •...
L. Serial A and Video Port Y. SysFan5 - LX version only LL.CMOS Config Jumper M. PS2 Stacked Mouse/Keyboard Z. SysFan4 MM.HSBP Connector Figure 2. Server Board Connector and Component Locations ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Pins 1-2 should be jumpered for normal system operation. If pins 2-3 are jumpered, the CMOS settings will be cleared on the next reset. These pins should not be jumpered for normal operation. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Network connection in place Blinking Amber Transmit/receive activity Right 10 Mbps connection (if left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
In order to operate in Dual Channel Dynamic Paging Mode, the following conditions must be met: • Two identical DIMMs are installed, one each in DIMM_1A and DIMM_1B • Four identical DIMMs are installed (one in each socket location) ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Hard Disk Drives The Server Board SE7230NH1-E supports up to four SATA devices. See the documentation included with your server chassis for additional drive information and drive installation instructions. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
If a value cannot be changed for any reason, the feature’s value field is inaccessible. Table 4 describes the keyboard commands you can use in the BIOS Setup menus. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
“No” is selected and the Enter key is pressed, or the ESC key is pressed, the user is returned to where they were before F10 was pressed without affecting any existing values. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
BIOS image file before attempting a BIOS upgrade. The release notes contain critical information regarding jumper settings, specific fixes, or other information to complete the upgrade. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
4. Disconnect the AC power and return the CMOS Clear jumper to the Normal location, covering pins 1 and 2. 5. Close the server chassis, reconnect the AC power, and power up the system. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
3). DDR DIMMs will not physically fit into a server board designed to support DDR2 DIMMs (see letter “B” in Figure Figure 3. DDR vs. DDR2 DIMMs ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
11. Replace the server's cover and reconnect the AC power cord. See the documentation that came with your server chassis for instructions on installing the server's cover. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
3. Disconnect the AC power cord from the server. 4. Remove the server's cover. See the documentation that came with your server chassis for instructions on removing the server's cover. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
6). Open the load plate as shown (see letter “B” in Figure Do not touch the processor socket contacts (see Figure Figure 6. Lift Processor Load Plate ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
9. Grasp the socket protective cover tab and pull away from the load plate (see letter “A” Figure 9). Remove the socket protective cover and store for future use (see letter “B” in Figure TP01788 Figure 9. Removing the Socket Protective Cover ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
(see letter “B” in Figure 11). The snaps go through the holes in the server board. 3. Press downward on top of each cap (see letter “C” in Figure 11). ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Installing the Passive Heat Sink If your server board is installed into the Intel Server Platform SR1475NH1-E, a custom copper 1U passive heat sink is installed. The heat sink must be installed with the solid copper sides of it facing to the left and to the right of the chassis.
Do not force the heat sink from the processor. Doing so could damage the processor. 9. Lift the processor lever. 10. Press the release button and lift the load plate. 11. Remove the processor. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run Setup to restore the configuration settings to the RTC. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
In addition to the server firmware and files, also update any drivers used for components you have installed in your system, such as video drivers, network drivers, and SCSI drivers. Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Additional Information and Software”...
Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their maximum ranges (see the documentation supplied with your video display monitor). ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
9. The bootable CD-ROM is not detected. Try the solutions below in the order given. If you cannot correct the problem, contact your service representative or authorized dealer for help. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
8. Remove all add-in cares and see if the video returns. If successful, add the cards back in one at a time with a reboot between each addition. 9. Make sure the memory DIMMs comply with the system requirements. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
4. Have any of the fan motors stopped? Use the server management subsystem to check the fan status. 5. Have your fans speeded up in response to an overheating situation? ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
6. Make sure the correct networking software is installed. 7. If you are directly connecting two servers (without a hub), you will need a crossover cable. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Before installing a PCI card, you should always: 1. Turn off the server power by using the power button on the front of the system. 2. Unplug the AC power cord(s) from the server. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Devices are not Recognized under Device Manager The Windows* operating systems do not include all of the drivers for the Intel chipsets, onboard NICs, and other components. See “Additional Information and Software” for a link to the current drivers and chipset files.
Replace or re-seat the system video add-in card. If on-board video is being used, the server board may be faulty. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an “Intel...
Costa Rica .. Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481 Panama ..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Page 51
Argentina..Contact AT&T USA at 0-800 222 1288. Once connected, dial 800 843 4481 Paraguay..001 916 377 0114 Peru .... 001 916 377 0114 Uruguay..001 916 377 0114 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Page 52
® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
• Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
-- on your server when handling parts. Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Weist darauf hin, daß das Anfassen des Gebläses zu Verletzungen führen kann. Bedeutet, alle Netzkabel abzuziehen und das Gerät von der Netzspannung zu trennen. Bereiten Sie bitte Batterie auf Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Page 60
Die Netzkabel sind die Hauptvorrichtung zum Trennen des Geräts vom Stromnetz. Die Steckdose muß in der Nähe der Anlage angebracht und gut erreichbar sein. • Netzkabel müssen an eine ordnungsgemäß geerdete Steckdose angeschlossen sein. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Page 66
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Page 67
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Page 72
CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Page 75
No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide...
Product EMC Compliance - Class A Compliance Note: Legally this product is required to comply with Class A emission requirements as it is intended for a commercial type market place. Intel targets 10db margin to Class A Limits. ® The Intel...
Regulatory Country Marking Compliance UL Mark USA/Canada CE Mark Europe FCC Marking (Class A) EMC Marking (Class A) Canada CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
CE Mark to illustrate its compliance. Taiwan Declaration of Conformity (BSMI) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Korean Compliance (RRL) English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
Page 86
® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
® Intel Server Issue Report Form Note: An on-line / automatic submission version of this form is available at http:// support.intel.com/support/motherboards/server/SE7230NH1-E/. For the fastest service, please submit your form via the Internet. Date Submitted: _______________________________________________________ Company Name: ______________________________________________________ Contact Name: ________________________________________________________...
PCI-X (64bit/ 100MHz) (Slot 5) PCI Express* x8 (x8 Lane - Slot 6) Full-height Riser PCI Riser Slot Video On-board Video Add-in Video On-Board NIC1 On-Board NIC2 ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Page 89
Hard Drive Information Drive Type (SCSI, Hot-swap or Make/Model SATA, etc) Fixed Revision Management Information On-Board Platform Instrumentation only ___________________________________ ® ® Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide...
Need help?
Do you have a question about the SR1475NH1 - Server Platform - 0 MB RAM and is the answer not in the manual?
Questions and answers