Sign In
Upload
Manuals
Brands
Intel Manuals
Server Board
SR1475NH1-E
Intel SR1475NH1-E Manuals
Manuals and User Guides for Intel SR1475NH1-E. We have
3
Intel SR1475NH1-E manuals available for free PDF download: User Manual, Technical Product Specification
Intel SR1475NH1-E Technical Product Specification (89 pages)
Server Chassis
Brand:
Intel
| Category:
Computer Accessories
| Size: 1.96 MB
Table of Contents
Revision History
2
Table of Contents
4
1 Intel
13
Chassis Views
13
Figure 1. Front Chassis View with Bezel
13
Figure 2. Front Chassis View Without Bezel
13
Figure 3. Rear Chassis View
13
Chassis Dimensions
14
Intel ® Server Chassis SR1475 System Components
14
Figure 4. Major Chassis Components
14
Table 1. Chassis Dimensions
14
Rear Panel Components
15
Hard Drive and Peripheral Bays
15
Figure 5. Back Panel Feature Overview
15
Table 2. Major Chassis Components
15
Control Panel
16
Figure 6. Front Panel Feature Overview
16
Figure 7. Control Panel Module
17
Figure 8. Standard Control Panel Overview
17
Power Sub-System
18
System Cooling
18
Chassis Security
18
Rack and Cabinet Mounting Options
18
Front Bezels
18
Figure 9. Optional Front Bezel
19
Figure 10. Front Bezel Options
19
2 Cooling Sub-System
20
System Fans
21
Power Supply Fans
22
Cpu/Memory Air Duct and Side Air Baffle
22
Figure 14. Air Baffle
22
Table 3. Individual Fan Assembly Pin-Out (J5J1, J4J1, J4J3, J4J2)
22
Figure 15. Cpu/Memory Air Duct
23
3 Peripheral and Hard Drive Support
24
Slim-Line Drive Bay
24
Figure 17. View of Slim-Line Drive Bay
24
Floppy Drive Support with or Without Backplane Present
25
Table 4. 4-Pin Floppy Power Connector Pin-Out (J3)
25
Table 5. 34-Pin Floppy Connector Pin-Out (J2)
25
CD-ROM or DVD-CDR Drive Use with or Without Backplane Present
26
Figure 18. Optional Floppy Drive Configuration
26
Optional Floppy Drive Configuration
26
Table 6. 50-Pin CD-ROM Connector Pin-Out (J6)
26
Table 7. 4-Pin CD-ROM Power Connector Pin-Out (J5)
27
Table 8. 40-Pin CD-ROM Connector Pin-Out (J1)
27
Hard Disk Drive Bays
28
Hot-Swap Hard Disk Drive Trays
28
Figure 19. Hard Disk Drive Bay
28
Fixed Drive Trays
29
Drive Blanks
29
Figure 20. Hard Drive Tray Assembly
29
Figure 21. Drive Tray with Drive Blank
29
Hot-Swap SCSI Backplane
30
SCSI Backplane Board Layout
30
Figure 22. SCSI Backplane Layout
30
SCSI Backplane Functional Architecture
31
Figure 23. SCSI Backplane Functional Diagram
31
Figure 24. Intel Server Chassis SR1475 SCSI HSBP I2C Bus Connection Diagram
33
SCSI Backplane Connector Definitions
34
Figure 25. 68-Pin SCSI Cable Connector
34
Table 9. SCSI Backplane Power Connector Pin-Out (J1)
34
Table 10. Ultrawide (SE) and Ultra2 (LVD) Ultra320 SCSI Connector Pin-Out (J8)
35
Figure 26. 80-Pin SCA2 SCSI Interface
36
Table 11. 80-Pin SCA2 SCSI Interface Pin-Out
36
Hot-Swap SATA Backplane
37
SATA Backplane Layout
38
Figure 27. SATA Backplane Layout
38
Figure 28. SATA Backplane Layout
38
SATA Backplane Functional Architecture
39
Figure 29. SATA Backplane Functional Block Diagram
39
Figure 30. Intel Server Chassis SR1475 SATA HSBP I2C Bus Connection Diagram
40
SATA Backplane Connector Definitions
41
Table 12. LED Function
41
Table 13. SATA Backplane Power Connector Pin-Out
41
Table 14. 7-Pin SATA Connector Pin-Out (J2, J3, J4, J5, J6)
42
Table 15. 22-Pin SATA Connector Pin-Out
42
4 Standard Control Panel
44
Standard Control Panel Buttons
44
Figure 31. Standard Control Panel Assembly Module
44
Figure 32. Standard Control Panel Buttons
44
Standard Control Panel LED Indicators
45
Table 16. Standard Control Panel Button Functions
45
Drive Activity LED
46
Power / Sleep LED
46
Table 17. Standard Control Panel LED Functions
46
Table 18. SSI Power LED Operation
46
System Identification LED
47
Control Panel Connectors
47
Internal Control Panel Assembly Headers
47
Table 19. External USB Connector (J2)
47
Table 20. 50-Pin Control Panel Connector (J3)
48
Table 21. Internal USB Header (J9F2)
48
5 PCI Riser Cards and Assembly
49
Figure 34. PCI Riser Bracket and Optional PCI-X* and PCI Express* Risers
49
Riser Card Options
50
Figure 35. 1U Full Height PCI-X* Riser Card Mechanical Drawing
50
Figure 36. 1U Full Height PCI Express* Riser Card Mechanical Drawing
50
6 Power Sub-System
51
Mechanical Specifications
51
Figure 37. Power Supply Enclosure Drawing
51
Airflow Requirements
52
Acoustics
52
Figure 38. Airflow Characteristics
52
Temperature
53
Output Connectors
53
Table 22. Acoustic Requirements
53
Table 23. Environmental Requirements
53
Table 24. Cable Lengths
53
P1 Main Power Connector
54
P2 Processor Power Connector
54
Table 25. P1 Main Power Connector
54
Table 26. P2 Processor Power Connector
54
HD Power Connector (P3)
55
Slim-Line Power Connector (P4)
55
AC Inlet Connector
55
Marking and Identification
55
Table 27. HD Power Connector
55
Table 28. Slim-Line Power Connector
55
AC Input Voltage
56
AC Line Transient Specification
56
Table 29. AC Input Rating
56
Table 30. AC Line Sag Transient Performance
56
Susceptibility
57
Electrostatic Discharge Susceptibility
57
Fast Transient/Burst
57
Radiated Immunity
57
Surge Immunity
57
Table 31. AC Line Surge Transient Performance
57
Table 32. Performance Criteria
57
AC Line Fast Transient (EFT) Specification
58
AC Line Dropout / Holdup
58
AC Line 5VSB Holdup
58
Power Recovery
58
Table 33. Dropout Criteria
58
Voltage Brown out
59
Voltage Interruptions
59
AC Line Inrush
59
AC Line Isolation Requirements
59
AC Line Leakage Current
59
AC Line Fuse
60
Power Factor Correction
60
Efficiency
60
Grounding
60
Remote Sense
60
Output Power / Currents
61
Standby Outputs
61
Fan Operation in Stand-By Mode
61
Voltage Regulation
61
Table 34. Load Ratings
61
Table 35. Voltage Regulation Limits
61
Dynamic Loading
62
Capacitive Loading
62
Closed Loop Stability
62
Table 36. Transient Load Requirements
62
Table 37. Capacitve Loading Conditions
62
Common Mode Noise
63
Ripple / Noise
63
Soft Starting
63
Zero Load Stability Requirements
63
Timing Requirements
63
Table 38. Ripple and Noise
63
Figure 39. Output Voltage Timing
64
Table 39. Output Voltage Timing
64
Table 40. Turn On/Off Timing
65
Residual Voltage Immunity in Standby Mode
66
Protection Circuits
66
Figure 40. Turn On/Off Timing (Power Supply Signals)
66
Over-Current Limit (OCP)
67
Over-Voltage Protection (OVP)
67
Table 41. over Current Protection (OCP)
67
Table 42. Over-Voltage Protection (OVP) Limits
67
Over-Temperature Protection (OTP)
68
Control and Indicator Functions
68
PSON # Input Signal
68
Table 43. PSON Signal Characteristic
68
PWOK (Power OK) Output Signal
69
Figure 41. PSON# Required Signal Characteristic
69
Table 44. PWOK Signal Characteristics
69
Environmental Requirements
70
Temperature
70
Humidity
70
Altitude
70
Mechanical Shock
70
Random Vibration
70
Thermal Shock (Shipping)
70
Ecological Requirements
70
Catastrophic Failure
70
7 Electromagnetic Compatibility
71
Emi
71
Input Line Current Harmonic Content (PFC)
71
Table 45. Harmonic Limits, Class a Equipment
71
Magnetic Leakage Fields
72
Voltage Fluctuations and Flicker
72
Reliability / Warranty / Service
72
Component De-Rating
72
Component Life Requirement
72
Mean Time between Failures (MTBF)
72
Warranty Period
72
Serviceability
73
Power Supply Returned for Repair
73
Modifications / Change Control
73
Power Supply Compliance Overview
73
Power Supplies Compliance Information
74
EMC Compliance Information
74
Immunity Compliance Information
75
Harmonics & Voltage Flicker Compliance Information
75
Environmental / Ecology Compliance Information
75
Other Safety Requirement Notations
76
Certification Conditions
76
Isolation between Primary - Secondary
76
Creepage & Clearance Requirements
76
Leakage Current Maximums
76
Max Surface Temperatures
76
Date Coded Serial Numbers
76
Power Input Electrical Ratings
76
Maximum Allowable Temperatures on Inlet Receptacles
76
Maximum Allowable Temperatures on Power Cords
76
8 Supported Intel Server Boards
77
Intel ® Server Board SE7230NH1-E Feature Set
77
Figure 42. SE7230NH1-E (LX) Board Layout
78
Table 46: Baseboard Layout Reference
79
9 Regulatory, Environmentals, and Specifications
80
Product Regulatory Compliance
80
Product Safety Compliance
80
Product EMC Compliance
80
Product Regulatory Compliance Markings
81
Electromagnetic Compatibility Notices
81
Usa
81
FCC Verification Statement
82
ICES-003 (Canada)
82
Europe (CE Declaration of Conformity)
82
Japan EMC Compatibility
83
BSMI (Taiwan)
83
Replacing the Back up Battery
84
System Level Environmental Limits
85
Serviceability
85
Table 47. System Office Environment Summary
85
Table 48. Mean Time to Repair Estimate
86
Appendix A: Intel Server Chassis SR1475 Integration and Usage Tips
88
Glossary
89
Advertisement
Intel SR1475NH1-E User Manual (90 pages)
Server Board and Server Platform
Brand:
Intel
| Category:
Server Board
| Size: 0.85 MB
Table of Contents
About this Manual
3
Manual Organization
3
Product Accessories
4
Additional Information and Software
4
Safety Information
7
Important Safety Instructions
7
Wichtige Sicherheitshinweise
7
Consignes de Sécurité
7
Instrucciones de Seguridad Importantes
7
Warnings
8
Table of Contents
9
List of Figures
13
List of Tables
15
Server Board Features
17
Figure 1. Intel ® Server Board SE7230NH1-E
17
Table 1. Server Board Features
18
Connector and Header Locations
20
Figure 2. Server Board Connector and Component Locations
20
Configuration Jumpers
21
Table 2. Configuration Jumpers
21
Back Panel Connectors
22
Table 3. LED Information
22
Hardware Requirements
23
Processor
23
Memory
23
Power Supply
24
Optional Hardware
24
Hard Disk Drives
24
Server Utilities
25
Using the BIOS Setup Utility
25
Starting Setup
25
If You Cannot Access Setup
25
Setup Menus
25
Table 4. Keyboard Commands
26
Upgrading the BIOS
27
Preparing for the Upgrade
27
Upgrading the BIOS
28
Clearing the CMOS
28
Hardware Installations and Upgrades
29
Before You Begin
29
Tools and Supplies Needed
29
Installing and Removing Memory
29
Figure 3. DDR Vs. DDR2 Dimms
29
Figure 4. Installing Dimms
30
Installing Dimms
30
Removing Dimms
31
Installing or Replacing the Processor
31
Installing the Processor
31
Figure 5. Lift Processor Socket Lever
32
Figure 6. Lift Processor Load Plate
32
Figure 7. Removing Protective Processor Cover
33
Figure 8. Installing the Processor
33
Figure 9. Removing the Socket Protective Cover
33
Installing the Active Heat Sink
34
Figure 10. Closing the Load Plate and Socket Lever
34
Installing the Passive Heat Sink
35
Figure 11. Installing the Active Heat Sink
35
Removing a Processor
36
Figure 12. Installing the Passive Heat Sink
36
Replacing the Backup Battery
37
Figure 13. Removing the Battery
38
Troubleshooting
39
Resetting the System
39
Problems Following Initial System Installation
39
Hardware Diagnostic Testing
40
Verifying Proper Operation of Key System Lights
41
Confirming Loading of the Operating System
41
Specific Problems and Corrective Actions
41
Power Light Does Not Light
42
No Characters Appear on Screen
42
Characters Are Distorted or Incorrect
43
System Cooling Fans Do Not Rotate Properly
43
Diskette Drive Activity Light Does Not Light
44
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light
44
Cannot Connect to a Server
44
Problems with Network
45
Problems with Newly Installed Application Software
46
Problems with Application Software that Ran Correctly Earlier
46
Devices Are Not Recognized under Device Manager
47
LED Information
47
Table 5. LED Information
47
BIOS POST Beep Codes
48
Table 6. POST Error Beep Codes
48
A Getting Help
49
World Wide Web
49
Telephone
49
Latin America
50
B Safety Information
53
English
53
Server Safety Information
53
Safety Warnings and Cautions
53
Intended Application Uses
54
Site Selection
54
Equipment Handling Practices
54
Power and Electrical Warnings
54
System Access Warnings
55
Rack Mount Warnings
56
Electrostatic Discharge (ESD)
56
Other Hazards
57
Sicherheitshinweise für den Server
58
Sicherheitshinweise und Vorsichtsmaßnahmen
58
Zielbenutzer der Anwendung
59
Standortauswahl
59
Handhabung von Geräten
59
Warnhinweise für den Systemzugang
61
Elektrostatische Entladungen (ESD)
62
Andere Gefahren
63
Français
64
Consignes de Sécurité Sur Le Serveur
64
Sécurité: Avertissements Et Mises en Garde
64
Domaines D'utilisation Prévus
65
Sélection D'un Emplacement
65
Pratiques de Manipulation de L'équipement
65
Décharges Électrostatiques†(ESD)
68
Avertissements Sur Le Montage en Rack
68
Autres Risques
69
Información de Seguridad del Servidor
70
Advertencias y Precauciones sobre Seguridad
70
Aplicaciones y Usos Previstos
71
Selección de la Ubicación
71
Manipulación del Equipo
71
Advertencias el Acceso al Sistema
73
Descarga Electrostática (ESD)
74
Advertencias sobre el Montaje en Bastidor
74
C Regulatory and Compliance Information
81
Product Regulatory Compliance
81
Product Safety Compliance
81
Product EMC Compliance - Class a Compliance
81
Certifications / Registrations / Declarations
82
Product Regulatory Compliance Markings
82
Table 7. Product Certification Markings
82
Electromagnetic Compatibility Notices
83
Fcc (Usa)
83
Industry Canada (ICES-003)
84
Europe (CE Declaration of Conformity)
84
Taiwan Declaration of Conformity (BSMI)
84
Korean Compliance (RRL)
85
D Intel ® Server Issue Report Form
87
Operating System Information
88
Intel SR1475NH1-E User Manual (90 pages)
Brand:
Intel
| Category:
Server Board
| Size: 0.79 MB
Table of Contents
Manual Organization
3
Product Accessories
4
Additional Information and Software
4
Important Safety Instructions
7
Consignes de Sécurité
7
Instrucciones de Seguridad Importantes
7
Warnings
8
Table of Contents
9
Server Board Features
17
Figure 1. Intel ® Server Board SE7230NH1-E
17
Table 1. Server Board Features
18
Connector and Header Locations
20
Figure 2. Server Board Connector and Component Locations
20
Configuration Jumpers
21
Table 2. Configuration Jumpers
21
Back Panel Connectors
22
Table 3. LED Information
22
Hardware Requirements
23
Processor
23
Memory
23
Power Supply
24
Optional Hardware
24
Hard Disk Drives
24
Server Utilities
25
Using the BIOS Setup Utility
25
Starting Setup
25
If You Cannot Access Setup
25
Setup Menus
25
Table 4. Keyboard Commands
26
Upgrading the BIOS
27
Preparing for the Upgrade
27
Upgrading the BIOS
28
Clearing the CMOS
28
Hardware Installations and Upgrades
29
Before You Begin
29
Tools and Supplies Needed
29
Installing and Removing Memory
29
Figure 3. DDR Vs. DDR2 Dimms
29
Figure 4. Installing Dimms
30
Installing Dimms
30
Removing Dimms
31
Installing or Replacing the Processor
31
Installing the Processor
31
Figure 5. Lift Processor Socket Lever
32
Figure 6. Lift Processor Load Plate
32
Figure 7. Removing Protective Processor Cover
33
Figure 8. Installing the Processor
33
Figure 9. Removing the Socket Protective Cover
33
Installing the Active Heat Sink
34
Figure 10. Closing the Load Plate and Socket Lever
34
Installing the Passive Heat Sink
35
Figure 11. Installing the Active Heat Sink
35
Removing a Processor
36
Figure 12. Installing the Passive Heat Sink
36
Replacing the Backup Battery
37
Figure 13. Removing the Battery
38
Troubleshooting
39
Resetting the System
39
Problems Following Initial System Installation
39
Hardware Diagnostic Testing
40
Verifying Proper Operation of Key System Lights
41
Confirming Loading of the Operating System
41
Specific Problems and Corrective Actions
41
Power Light Does Not Light
42
No Characters Appear on Screen
42
Characters Are Distorted or Incorrect
43
System Cooling Fans Do Not Rotate Properly
43
Diskette Drive Activity Light Does Not Light
44
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light
44
Cannot Connect to a Server
44
Problems with Network
45
Problems with Newly Installed Application Software
46
Problems with Application Software that Ran Correctly Earlier
46
Devices Are Not Recognized under Device Manager
47
LED Information
47
Table 5. LED Information
47
BIOS POST Beep Codes
48
Table 6. POST Error Beep Codes
48
A Getting Help
49
World Wide Web
49
Telephone
49
B Safety Information
53
English
53
Server Safety Information
53
Safety Warnings and Cautions
53
Intended Application Uses
54
Site Selection
54
Equipment Handling Practices
54
Power and Electrical Warnings
54
System Access Warnings
55
Rack Mount Warnings
56
Electrostatic Discharge (ESD)
56
Other Hazards
57
Sicherheitshinweise für den Server
58
Sicherheitshinweise und Vorsichtsmaßnahmen
58
Zielbenutzer der Anwendung
59
Standortauswahl
59
Handhabung von Geräten
59
Warnhinweise für den Systemzugang
61
Elektrostatische Entladungen (ESD)
62
Andere Gefahren
63
Français
64
Consignes de Sécurité Sur Le Serveur
64
Sécurité: Avertissements Et Mises en Garde
64
Domaines D'utilisation Prévus
65
Sélection D'un Emplacement
65
Pratiques de Manipulation de L'équipement
65
Décharges Électrostatiques†(ESD)
68
Autres Risques
69
Información de Seguridad del Servidor
70
Advertencias y Precauciones sobre Seguridad
70
Aplicaciones y Usos Previstos
71
Selección de la Ubicación
71
Manipulación del Equipo
71
Advertencias el Acceso al Sistema
73
Descarga Electrostática (ESD)
74
C Regulatory and Compliance Information
81
Product Regulatory Compliance
81
Product Safety Compliance
81
Product EMC Compliance - Class a Compliance
81
Certifications / Registrations / Declarations
82
Product Regulatory Compliance Markings
82
Table 7. Product Certification Markings
82
Electromagnetic Compatibility Notices
83
Fcc (Usa)
83
Industry Canada (ICES-003)
84
Europe (CE Declaration of Conformity)
84
Taiwan Declaration of Conformity (BSMI)
84
Korean Compliance (RRL)
85
D Intel ® Server Issue Report Form
87
Advertisement
Advertisement
Related Products
Intel SR1475NH1 - Server Platform - 0 MB RAM
Intel SR1690WB - Server System - 0 MB RAM
Intel SR2400
Intel SR1400SYS - Server Platform - 0 MB RAM
Intel Chassis SR1450
Intel SR1670HV - Server System - 0 MB RAM
Intel SR1400
Intel SR1300
Intel SE7501CW2
Intel S2600ST
Intel Categories
Motherboard
Computer Hardware
Server
Server Board
Desktop
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL