Fan bracket

Note:
Complete the following steps to remove the fan brackets:
1. Turn off the server and all attached peripheral devices.
2. Disconnect all power cords and external cables from the back of the server.
3. If necessary, remove the server from the rack; then, remove the server cover
Figure 51. Fan bracket removal
4. Unplug the fans from the system board.
5. Remove the fans from the system (see "Replacing a hot-swap fan assembly" on
6. Remove the screws and set them in a safe place.
7. Disconnect the fan cable.
8. Pull the fan bracket out of the server.
To install the fan brackets, reverse this procedure.
Note: When reinstalling the fan brackets on the front right side of the server,
56
xSeries 336 Type 1879 and Type 8837: Hardware Maintenance Manual and Troubleshooting Guide
v Read "Installation guidelines" on page 15.
v Read the safety notices at Appendix B, "Safety information," on page 129.
v Read "Handling static-sensitive devices" on page 16.
(see "Removing the cover" on page 18).
page 43).
remove the drive tray assembly (see "Drive tray assembly" on page 57) and
the fan cable cover. Pull the cable loose before plugging it into the fan power
distribution board on the fan bracket, then install the fan bracket in the
server.