Juniper JUNOSE 11.0.X PHYSICAL LAYER Configuration Manual page 59

For e series broadband services routers - physical layer configuration
Table of Contents

Advertisement

show controllers t3 ft1
Number of valid interval - 90
Time elapse in current interval - 580
Ds1 Current Interval Counters
Errored seconds = 0
Severely errored second = 0
Severely errored frame seconds = 0
Unavailable seconds = 0
Clock slip seconds = 0
Path code violations = 0
Line errored seconds = 0
Bursty errored seconds = 0
Degraded minutes = 0
Line code violations = 0
Ds1 Last Interval Counters
Errored seconds = 0
Severely errored second = 0
Severely errored frame seconds = 0
Unavailable seconds = 0
Clock slip seconds = 0
Path code violations = 0
Line errored seconds = 0
Bursty errored seconds = 0
Degraded minutes = 0
Line code violations = 0
Ds1 24 Hour Total Counters
Errored seconds = 25
Severely errored second = 7
Severely errored frame seconds = 25
Unavailable seconds = 0
Clock slip seconds = 6
Path code violations = 18
Line errored seconds = 0
Bursty errored seconds = 0
Degraded minutes = 0
Line code violations = 0
See show controllers t1.
See show controllers t3.
Use to display information about the state of a fractional T1 subchannel.
Field descriptions
Description Text description or alias if configured for the interface
ifOperStatus Physical status of the interface
ifOperUp Interface is functioning
ifOperTesting Interface is being tested
ifOperNotPresent Module has been removed from the chassis
ifOperDown Interface is not functioning
Chapter 1: Configuring Channelized T3 Interfaces