32
Monitoring Interfaces
Number of valid intervals Number of 15-minute intervals since the line
module was last powered on or reset
Time elapse in current interval Reported in 15-second intervals
P-bit errored seconds Number of errored seconds encountered by a T3 in
the current interval
P-bit severely errored seconds Number of severely errored seconds
encountered by a T3 in the current interval
Severely errored frame seconds Number of severely errored framing
seconds encountered by a T3 in the current interval
Unavailable seconds Number of unavailable seconds encountered by a T3
in the current interval
Line code violations Number of line code violations encountered by a T3
in the current interval
P-bit coding violations Number of coding violations encountered by a T3
in the current interval
Line errored seconds Number of line errored seconds encountered by a
T3 in the current interval
C-bit coding violations Number of C-bit coding violations encountered by
a T3 in the current interval
C-bit errored seconds Number of C-bit errored seconds encountered by a
T3 in the current interval
C-bit severely errored seconds Number of C-bit severely errored seconds
encountered by a T3 in the current interval
Example 1 In this example, a T3 interface is specified.
host1#show controllers t3 2/0
DS3 2/0
Description: toronto ct3 interface
ifAdminStatus = ifAdminDown
snmp trap link-status = enabled
No alarms detected
Framing is C-BIT, Line Code is B3ZS, Clock Source is Line
Cable Length is 0 ft
Loopback Disabled
MDL Transmit Path is not active
MDL Transmit Test-Signal is active
MDL Transmit Idle-Signal is not active
Equipment Identification Code is ERX-1400
Line Identification Code is Bldg 10
Frame Identification Code is null string
Unit Identification Code is 080001
Facility Identification Code is Site 25
Port Code is Port 0800
Generator Number is null string
Number of valid interval - 96
Time elapse in current interval - 861