Advanced Insight Scripts (AI-Scripts) 2.5 Release Notes
Table 1: Events Detected by AI-Scripts (continued)
EVENT ID
SYSTEM: writing kernel
SYSTEM:.*cm_read_i2c errno is 5.*
SYSTEM:.*cm_read_i2c errno is 5.*
SYSTEM:.*snp_igmp_io_flood: relay failed.*
TASK_OS_MEMHIGH
TASK_SYSTEM
UI_DBASE_REBUILD_FAILED
UI_DBASE_REBUILD_SCHEMA_FAILED
UI_DBASE_REOPEN_FAILED
UI_SCHEMA_SEQUENCE_ERROR
UTMD_MALLOC_FAILURE
UTMD_SSAMLIB_FAILURE
VCCPD_PROTOCOL_LSPCKSUM
VCCPD_PROTOCOL_OVERLOAD
VRRPD_MISSING_VIP
28
DESCRIPTION
A kernel crash event. A writing kernel message is captured after the router
reboots.
The chassis manager event message results from an error in calculating the
DC power budget for POE interfaces.
The chassis manager event message results from an error in calculating the
DC power budget for POE interfaces.
This message indicates that the device is flooding IGMP unknown packet
back on the same port that it was received on.
The process is using the indicated amount and percentage of Routing
Engine memory, which is considered excessive.
A system call made by this process failed.
The management process (mgd) could not rebuild the configuration
database file.
The management process (mgd) could not rebuild the schema for the
configuration database.
After rebuilding the schema file for the configuration database, the
management process (mgd) closes the file and reopens it in read-only mode
to prevent corruption. It could not reopen the file.
The Junos user interface schema file records all CLI commands and
configuration statements available in the Junos operating system. The
management process (mgd) rebuilds the schema as necessary to be
compatible with the Junos software installed on the device. A sequence
number in the schema acts as a checksum that represents its content and
format. A Junos process attempted to access the schema but determined
that the schema's sequence number means that it is incompatible with the
process.
The example process (utmd) could not allocate memory for a resource,
possibly due to a lack of memory.
The example process (utmd) encountered an error while calling a function
or from a callback of the ssamlib library.
The indicated vccpd link-state PDU (LSP) failed an internal checksum
validity test, implying that it was corrupted.
The vccpd link-state database is full and no additional memory can be
allocated for it.
The indicated interface received a Virtual Routing Redundancy protocol
(VRRP) packet for the indicated VRRP group in which the indicated Virtual
IP address was missing.
©
Copyright