Juniper ADVANCED INSIGHT SCRIPTS 2.5 - RELEASE NOTES REV 1 Release Note page 15

Table of Contents

Advertisement

Table 1: Events Detected by AI-Scripts (continued)
EVENT ID
EVENTD_FORK_ERR
EVENTD_PIPE_ERR
EVENTD_VERSION_MISMATCH
FPCLOGIN_IP_ADDRESS_GET_FAILURE
FSAD_ERROR
FUD_MEMORY_ALLOCATION_FAILURE
FUD_RTSOCK_WRITE_FAILURE
FUD_SENDMSG_FAILURE
FUD_SENDMSG_NOINT_FAILURE
FUD_SETSOCKOPT_FAILURE
FUD_SOCKET_FAILURE
GGSN_ALARM_TRAP_SEND
GGSN_TRAP_SEND
GRAPH_NO_MEMORY
HNCACHED_PATRICIA_ERROR
ICCPD_ASSERT_SOFT
ICCPD_OPEN_ERROR
IDP_DAEMON_INIT_FAILED
©
Copyright
2010, Juniper Networks, Inc.
DESCRIPTION
The event processing process (eventd) could not create a child process for
executing policies.
The event processing process (eventd) could not create a pipe for
interprocess communication.
The event processing process (eventd) received an event with the indicated
version indicator, which does not match the indicated version expected by
eventd.
The fpclogin module attempted to get the IP address of the physical
interface module. The attempt failed.
The file system access process (fsad) internal error message.
The UDP forwarding process (fud) could not allocate the indicated amount
of memory from the heap.
The UDP forwarding process (fud) could not write to its routing socket for
the indicated reason.
The UDP forwarding process (fud) could not send data to the indicated
destination port and address using the indicated interface and routing
instance, which it needs to do during normal operation.
The UDP forwarding process (fud) could not send data to the indicated
destination port and address using the indicated routing instance, which it
needs to do during normal operation.
The UDP forwarding process (fud) could not set the indicated socket option.
The UDP forwarding process (fud) could not create a socket.
An alarm trap to be relayed by the services PICs process (serviced) failed to
initialize.
The system sent a GGSN trap of an unrecognized type.
The graphing process could not allocate memory while trying to create a
graph.
A call to a Patricia tree library function returns an error.
The source code for the interchassis communication process (iccpd)
includes internal self-consistency checks. As iccpd with the indicated
process ID (PID) executed the binary compiled from the indicated source
file, a check failed at the indicated line number in the file. iccpd created a
diagnostic core file for analysis by technical support personnel and
continued to run.
The interchassis communication process (iccpd) could not initialize.
An attempt to start the IDP policy daemon failed because an error was
encountered during initialization.
Events Detected by AI-Scripts
15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVANCED INSIGHT SCRIPTS 2.5 - RELEASE NOTES REV 1 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents