Advanced Insight Scripts (AI-Scripts) 2.5 Release Notes
Table 1: Events Detected by AI-Scripts (continued)
EVENT ID
LPDFD_RTSOCK_OPEN_FAILURE
MIB2D_REALPATH_FAILURE
MIB2D_RTSLIB_READ_FAILURE
MIB2D_SNMP_INDEX_ASSIGN
MIB2D_SNMP_INDEX_DUPLICATE
MIB2D_SNMP_INDEX_UPDATE_STAT
MIB2D_SNMP_INDEX_WRITE
NSD_MEMORY_ALLOC_FAILED
NSD_SEC_NODE_COMP_SYNC_FAILED
NSTRACED_MEMORY_ALLOC_FAILED
NSTRACED_SSAMLIB_CALL_FAILED
PFE Crash
PFE: ASIC Initialization Error
PFE: CMRFEB: Fatal HSL2 errors for FPC
PFE: DFW: jtree cutover failed
PFE: Failed to find MC RT_NH entry:.*
PFE: HSL2–HSL2 detected fatal error
PFE: I-CHIP New illegal link errors in WO DESRD
20
DESCRIPTION
The local policy decision function (LPDF) services process could not
successfully open a routing socket to the kernel. The error string
accompanying this log entry indicates the specific error.
When MIB2D is copying the /var/db/dcd.snmp_ix file, it could not resolve
its real path.
A call to the indicated function in the routing socket library failed during the
indicated operation on the indicated object.
MIB2D cannot assign an SNMP index for each interface.
The first interface name was assigned the same SNMP index as the second
interface name.
MIB2D cannot get the status of the SNMP index file.
MIB2D cannot write to a file containing all the indices.
The network security process (nsd) could not allocate the indicated number
of bytes of memory.
One or more subcomponents of the network security process (nsd) failed to
synchronize their state when the nsd restarted on secondary mode.
The USP trace process (nstraced) could not allocate the indicated number
of bytes of memory.
The indicated error occurred when the usp trace daemon process (nstraced)
called a function in the ssamlib library or tried to process a callback from the
library.
Any Packet Forwarding Engine board crash that occurs in conjunction with a
system exception message.
Any Packet Forwarding Engine ASIC initialization error that occurs in
conjunction with a system exception message, such as: router-name fpc5
CMG: Fatal ASIC initialization error, Offlining FPC
A switching board (for example, FEB) is reporting a bad fabric connection to
an FPC.
The firewall filter configuration cannot be applied due to insufficient amount
of contiguous memory on the SRAM.
Informational message logged when multicast next-hop traffic ages from the
switch routing tables.
The FPC detected a fatal HSL2 error.
Potential ICHIP stream problem possibly due to IFL flooding. Potential
match with PR/289104—may need software upgrade.
©
Copyright
2010, Juniper Networks, Inc.
Need help?
Do you have a question about the ADVANCED INSIGHT SCRIPTS 2.5 - RELEASE NOTES REV 1 and is the answer not in the manual?