Juniper ADVANCED INSIGHT SCRIPTS 2.5 - RELEASE NOTES REV 1 Release Note page 10

Table of Contents

Advertisement

Advanced Insight Scripts (AI-Scripts) 2.5 Release Notes
Table 1: Events Detected by AI-Scripts (continued)
EVENT ID
CHASSISD_GBUS_READBACK_ERROR
CHASSISD_HSR_FIFO_ERROR
CHASSISD_I2C_BAD_IDEEPROM_FORMAT
CHASSISD_I2C_READ_ERROR
CHASSISD_I2CS_READBACK_ERROR
CHASSISD_IFDEV_DETACH_FPC
CHASSISD_IFDEV_DETACH_PIC
CHASSISD_IPC_CONNECTION_DROPPED
CHASSISD_IPC_DAEMON_WRITE_ERROR
CHASSISD_IPC_MSG_DROPPED
CHASSISD_IPC_MSG_UNHANDLED
CHASSISD_IPC_WRITE_ERR_NULL_ARGS
CHASSISD_MAC_ADDRESS_ERR
CHASSISD_MAC_ADDRESS_FABRIC_ERR
10
DESCRIPTION
There was an error when the chassis process (chassisd) tried to read back
information from the GBUS on the indicated component (field-replaceable
unit, or FRU).
A first-in, first-out (FIFO) read error occurred during execution of the
indicated routine on the indicated high-speed receiver (HSR).
The chassis process (chassisd) determined that the ID EEPROM format
specified for the indicated type of hardware component (field-replaceable
unit, or FRU) is not valid for it.
The chassis process (chassisd) cannot read I2C data from the indicated
device.
The chassis process (chassisd) cannot read back information from the I2C
slave (I2CS) about the indicated component (field-replaceable unit, or
FRU).
The chassis process (chassisd) detached the interface devices for all PICs
on the indicated Flexible PIC Concentrator (FPC).
The chassis process (chassisd) detached the interface devices for the
indicated PIC.
The chassis process (chassisd) dropped the interprocess communication
(IPC) connection to the indicated component (field-replaceable unit, or
FRU).
The chassis process (chassisd) could not write to a socket because of the
indicated error. The socket is for a connection to another process that runs
on the Routing Engine and helps manage the chassis.
The chassis process (chassisd) dropped an interprocess communication
(IPC) message because the message queue had already reached
maximum capacity.
The chassis process (chassisd) received an interprocess communication
(IPC) message about the indicated FRU. The message had the indicated
characteristics. chassisd could not handle the message.
The chassis process (chassisd) could not send a message to the indicated
component (field-replaceable unit, or FRU) because one or more required
parameters had a null value.
The chassis process (chassisd) could not obtain a media access control
(MAC) address for the indicated interface because of an internal error.
The chassis process (chassisd) could not obtain a media access control
(MAC) address for the indicated fabric interface because of an internal
error.
©
Copyright
2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVANCED INSIGHT SCRIPTS 2.5 - RELEASE NOTES REV 1 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents