Table 1: Events Detected by AI-Scripts (continued)
EVENT ID
CHASSISD_MALLOC_FAILURE
CHASSISD_MBE_DETECTED
CHASSISD_OVER_TEMP_CONDITION
CHASSISD_OVER_TEMP_SHUTDOWN_TIME
CHASSISD_PEM_OVERLOAD
CHASSISD_PEM_VOLTAGE
CHASSISD_PIC_HWERROR
CHASSISD_POWER_CONDITION
CHASSISD_PSU_ERROR
CHASSISD_PSU_FAN_FAIL
CHASSISD_PSU_INPUT_BAD
CHASSISD_PSU_OVERLOAD
CHASSISD_PSU_TEMPERATURE
CHASSISD_PSU_VOLTAGE
CHASSISD_RE_OVER_TEMP_CONDITION
©
Copyright
2010, Juniper Networks, Inc.
DESCRIPTION
The chassis process (chassisd) could not allocate memory. chassisd tried
to continue functioning, but the lack of memory usually causes the process
to fail. An administrator needs to restart it.
A multibit ECC parity error was detected in the Routing Engine DRAM.
The temperature of one or more components (field-replaceable units, or
FRUs) exceeded the indicated temperature, which is the upper of two
thresholds. The fans (and impellers, if applicable) were in the indicated
state. If the temperature does not go below the threshold within four
minutes after the chassis process (chassisd) detects this condition,
chassisd shuts down the device. When this message was logged, the
indicated number of seconds remained before shutdown.
The chassis process (chassisd) shut down the device because the
temperature of one or more components exceeded the indicated threshold
temperature for the indicated amount of time. Continued operation at the
excessive temperature could damage the device.
The indicated power entry module (PEM) reported an output voltage
overload condition.
The indicated power entry module (PEM) reported a problem with its
output voltage.
The indicated PIC experienced a hardware error. The chassis process
(chassisd) did not bring the PIC online.
The temperature of the indicated Routing Engine exceeded the indicated
temperature, which is the upper of two thresholds.
The chassis process (chassisd) detected the indicated error condition for
the indicated power supply unit (PSU).
The PSU fan-fail bit is set in the status for the indicated power supply unit
(PSU).
The chassis process (chassisd) detected the input voltage/warning fault
condition for the indicated power supply unit (PSU).
The indicated power supply unit (PSU) reported an output voltage overload
condition.
The chassis process (chassisd) detected that the temperature check bit
was set in the status bit mask for the indicated power supply unit (PSU).
The indicated power supply unit (PSU) reported a problem with its output
voltage.
The temperature of the indicated Routing Engine exceeded the indicated
temperature, which is the upper of two thresholds.
Events Detected by AI-Scripts