Advanced Insight Scripts (AI-Scripts) 2.5 Release Notes
Table 1: Events Detected by AI-Scripts (continued)
EVENT ID
CHASSISD_RE_OVER_TEMP_SHUTDOWN
CHASSISD_RE_OVER_TEMP_WARNING
CHASSISD_SBE_DETECTED
CHASSISD_SIB_INVALID_SLOT
CHASSISD_SMB_INVALID_PS
CHASSISD_SMB_IOCTL_FAILURE
CHASSISD_SMB_READ_FAILURE
CHASSISD_TEMP_SENSOR_FAILURE
CHASSISD_TIMER_VAL_ERR
CHASSISD_UNEXPECTED_EXIT
CHASSISD_VOLTAGE_READ_FAILED
CHASSISD_VOLTAGE_SENSOR_INIT
CONNECTION_CHASSISD_FAIL
CONNECTION_CRAFTD_FAIL
12
DESCRIPTION
The chassis process (chassisd) performed the indicated action because
the temperature of the indicated Routing Engine exceeded the maximum
threshold for more than four minutes. Continued operation at the excessive
temperature could damage device components.
The temperature of the indicated Routing Engine exceeded the indicated
temperature, which is the upper of two thresholds. If the temperature does
not go below the threshold within four minutes after the chassis process
(chassisd) detects this condition, chassisd shuts down the indicated
component. When this message was logged, the indicated number of
seconds remained before shutdown.
Too many single-bit correctable ECC parity errors were detected in
Routing Engine DRAM.
The chassis process (chassisd) detected the presence of a Switch
Interface Board (SIB) in an invalid slot. The SIB remains offline.
The chassis process (chassisd) could not set the status (enabled or
disabled) for a power supply because it received the indicated power
supply status code, which is invalid.
The indicated ioctl() operation failed at the indicated address on the system
management bus (SMB).
A read() operation failed at the indicated address on the system
management bus (SMB).
The temperature sensor for the indicated component (field-replaceable
unit, or FRU) either did not respond to a request from the chassis process
(chassisd) for a temperature reading or sent a value that is outside the
normal operating range.
The chassis process (chassisd) started a timer to track the timeout period
for an event. The timer returned a null identifier, so chassisd could not
clear the timer.
The chassis process (chassisd) exited unexpectedly and reported the
indicated error.
The chassis process (chassisd) could not read the voltage data from the
indicated component (field-replaceable unit, or FRU).
The chassis process (chassisd) could not initialize the voltage sensor for
the indicated component (field-replaceable unit, for FRU).
The alarm process (alarmd) was unable to connect to the chassis process
(chassisd).
The alarm process (alarmd) was unable to connect to the craft process
(craftd).
©