NETGEAR GS724TS - ProSafe 24 Port Gigabit Stackable Smart Switch Software Administration Manual page 65

Gigabit stackable smart switch
Hide thumbs Also See for GS724TS - ProSafe 24 Port Gigabit Stackable Smart Switch:
Table of Contents

Advertisement

GS700TS Smart Switch Software Administration Manual
2. Select the group entry.
3. Click DELETE to remove the entry.
User Configuration
The SNMPv3 User Configuration screen provides information for creating users, assigning the
user a group, an Engine Id, and Authentication attributes.
To define SNMP users:
1. Click System > SNMP > SNMPv3 > User Configuration. The SNMPv3 User Configuration
screen displays:
Figure 3-16
The SNMPv3 User Configuration screen contains the following fields:
User Name – Enter the user name. The field range is up to 30 alphanumeric characters.
Group Name – Enter the group name from a list of user-defined SNMP groups. SNMP
groups are defined in the Groups screen.
Engine ID – Select either the local or remote SNMP entity to which the user is connected.
Changing or removing the local SNMP Engine ID deletes the SNMPv3 user database.
Authentication – Select the method used to authenticate users. The possible field values
are:
None – No user authentication is used.
MD5 Password – Indicates the HMAC-MD5-96 password is used for authentication.
The user must enter a password.
Managing System Settings
v1.0, June 2009
3-30