Download Print this page
HPE ProLiant Compute DL360 Gen12 User Manual
HPE ProLiant Compute DL360 Gen12 User Manual

HPE ProLiant Compute DL360 Gen12 User Manual

Advertisement

Quick Links

HPE ProLiant Compute DL360 Gen12 Server User Guide
HPE ProLiant Compute DL360 Gen12 Server User Guide
Part Number: 30-619DBC1F-001
Published: April 2025
Edition: 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProLiant Compute DL360 Gen12 and is the answer not in the manual?

Questions and answers

Summary of Contents for HPE ProLiant Compute DL360 Gen12

  • Page 1 HPE ProLiant Compute DL360 Gen12 Server User Guide HPE ProLiant Compute DL360 Gen12 Server User Guide Part Number: 30-619DBC1F-001 Published: April 2025 Edition: 1...
  • Page 2 HPE ProLiant Compute DL360 Gen12 Server ProLiant Compute DL360 Gen12 Server User Guide User Guide Abstract Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels, and are familiar with the weight and stability precautions for rack installations.
  • Page 3: Table Of Contents

    Fan numbering Fan and heatsink requirements Heatsink and processor socket components Closed-loop liquid cooling heatsink components HPE NS204i-u Boot Device V2 components HPE NS204i-u Boot Device V2 LED definitions Riser board components Riser slot numbering Setup HPE Installation Service Setting up the server...
  • Page 4 Operations Intel VROC support Server UID LED Using the UID button to view the Server Health Summary Display device setup Trusted Platform Module 2.0 Trusted Platform Module 2.0 guidelines System battery information Hardware options Hewlett Packard Enterprise product QuickSpecs Hardware option installation guidelines Pre-installation procedures Server data backup Power down the server...
  • Page 5 Installing the 8 SFF optical disk drive Installing the DisplayPort / USB / optical drive blank option and optical drive in the mixed drive type configuration Memory HPE SmartMemory speed and population information DIMM installation guidelines Installing a DIMM blank...
  • Page 6 Connecting the direct liquid cooling kit Rack rail and CMA Rack mounting interfaces Rack rail options Rail identification markers Installing the rack rails Installing the server into the rack Installing the rack rail hook-and-loop strap Installing the cable management arm Risers and riser cages Primary PCI riser cage options Installing an expansion board in slot 1...
  • Page 7 Environmental specifications Mechanical specifications Power supply specifications HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 1000 W Flex Slot Titanium Hot-plug Power Supply HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 1600 W Flex Slot -48 VDC Hot-plug Power Supply...
  • Page 8 HPE 1800-2200 W Flex Slot Titanium Power Supply Support and other resources Accessing Hewlett Packard Enterprise Support HPE product registration Accessing updates Customer self repair Remote support Documentation feedback...
  • Page 9: Component Identification

    (USB Type C) Drive bays This option replaces the blank. The serial number / iLO information pull tab is double-sided. One side shows the server serial number and the customer asset tag HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 10 The drive boxes support hardware options for the mixed drive type configuration. Item Item Description Description Serial number/iLO information pull tab iLO service port (USB Type C) USB 3.2 Gen1 port Drive bays HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 11: Ilo Service Port

    When you use this feature, the connected USB flash drive is not accessible by the host OS. Connect a host system (Windows/Mac/Linux laptop or desktop) using either a standard USB Type A‑to‑Type C cable or USB Type C‑to‑Type C cable to access the: iLO web interface HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 12: Front Panel Leds And Buttons

    You cannot access the connected device from the server. For more information about the iLO service port, see the iLO user guide: https://www.hpe.com/support/hpeilodocs-quicklinks https://www.hpe.com/support/hpeilodocs-quicklinks Front panel LEDs and buttons Front panel LEDs and buttons HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 13: Uid Button Functionality

    The UID button can be used to identify a specific server in a rack or display the Server Health Summary when the server will not power on. For more information, see the latest HPE iLO User Guide on the Hewlett Packard Enterprise website Hewlett Packard Enterprise website .
  • Page 14: Systems Insight Display Leds

    DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known working DIMM. For information about memory population rule, see the relevant memory technical paper in: https://www.hpe.com/docs/server-memory https://www.hpe.com/docs/server-memory HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 15: Systems Insight Display Combined Led Descriptions

    DIMM group LEDs Normal Solid amber Failed DIMM group or configuration issue To enable Advanced Memory Protection (AMP), see the UEFI user guide ( https://www.hpe.com/support/hpeuefisystemutilities- https://www.hpe.com/support/hpeuefisystemutilities- quicklinks). quicklinks When the health LED on the front panel illuminates either amber or red, the server is experiencing a health event. For more information on the combination of these LEDs, see Systems Insight Display combined LED descriptions .
  • Page 16: Rear Panel Components

    One or more DIMMs have failed. Flashing amber Solid green DIMM in slot X is in a pre-failure condition. Rear panel components Rear panel components Rear panel with 3 PCIe slots Rear panel with 3 PCIe slots HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 17 This slot supports full-height PCIe form factor. This slot supports low-profile PCIe form factor. This slot requires the low-profile riser kit option (P48903-B21). Rear panel with 2 PCIe slots Rear panel with 2 PCIe slots HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 18: Rear Panel Leds

    Rear UID button / LED OCP 3.0 slot A (Slot 14) This slot supports full-height PCIe form factor. This slot requires the full-height riser kit option (P72598-B21). Rear panel LEDs Rear panel LEDs HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 19: Component Touchpoints

    Certain components are color-coded. These colors represent the recommended touch areas for a removal process and indicate whether components require a system shutdown before removal. The following diagrams are examples only. HPE hot-plug red hot-plug red HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 20: System Board Components

    Touchpoint blue indicates cold-pluggable components. These components require a system shutdown. Failure to do so might result in system failure or data loss. Cold-pluggable components might also indicate touchpoints on non-electrical components. Component examples: Storage devices Fan cages System boards Energy packs System board components System board components HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 21 HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 22: System Maintenance Switch Descriptions

    There is no available SmartNIC 4-pin power cable option. Subtopics Subtopics System maintenance switch descriptions System maintenance switch descriptions DIMM label identification DIMM label identification DIMM slot locations DIMM slot locations System maintenance switch descriptions System maintenance switch descriptions HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 23: Dimm Label Identification

    The label contains information about the DIMM. For additional information about DIMMs, including: Memory speeds and server-specific DIMM population rules Product features, specifications, options, configurations, and compatibility See the website: https://www.hpe.com/docs/server-memory https://www.hpe.com/docs/server-memory HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 24: Dimm Slot Locations

    The maximum memory speed and capacity is a function of the memory type, memory configuration, and processor model. DIMM slot locations DIMM slot locations DIMM slots are numbered sequentially (1 through 16) for each processor. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 25: Drive Bay Numbering

    4 LFF drive bay numbering 4 LFF drive bay numbering 8 SFF drive bay numbering 8 SFF drive bay numbering 8 + 2 SFF drive bay numbering 8 + 2 SFF drive bay numbering HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 26: Drive Backplane Naming

    Drive backplane naming This topic explains the features represented in the drive backplane naming. This naming convention was adopted starting in the HPE Gen11 server release. Your server might not support all the features listed in this topic. For server-specific support information, see the server guides: Drive backplane support, see Drive bay numbering.
  • Page 27: Ocp Nic 3.0 Slot Numbering

    To support Slot 15 OCP B x8 connection in a single processor configuration, a CPU1-to-OCP-B cable option (P72203-B21) is required. To support Slot 15 OCP B x8 connection in a dual processor configuration, a CPU2-to-OCP-B cable option (P72205-B21) is required. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 28: Hpe Basic Drive Led Definitions

    HPE Basic Drive LED definitions Basic Drive LED definitions The HPE Basic drive carrier has the following LEDs: Amber/blue LED—Managed by the drive backplane in conjunction with the storage controller and is used to indicate drive status. Green LED—Managed by the drive itself and indicates the drive activity.
  • Page 29: Edsff Ssd Led Definitions

    The EDSFF drive carrier has two LEDs: Amber/blue LED—Managed by the drive backplane in conjunction with the storage controller and is used to indicate drive status. Green LED—Managed by the drive itself and indicates the drive activity. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 30: Fan Numbering

    The drive is operating normally and has activity. flashes per second) No power present. Fan numbering Fan numbering The arrow points to the front of the server. Single processor Single processor Single or dual processor Single or dual processor HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 31: Fan And Heatsink Requirements

    Heatsink type Heatsink type SAS/SATA drives Standard fan Standard or high performance heatsink E3.S / NVMe / SAS4 drives / HPE NS204i-u High performance fan Standard or high performance heatsink Boot Device V2 256 GB or higher capacity DIMMs High performance fan...
  • Page 32: Heatsink And Processor Socket Components

    High-performance fans are required for ASHRAE-compliant configurations. For more information on ASHRAE, see the Hewlett Packard Enterprise website (https://www.hpe.com/support/ASHRAEGen12 https://www.hpe.com/support/ASHRAEGen12). Heatsink and processor socket components Heatsink and processor socket components A high-performance heatsink is shown. Your heatsink might look different. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 33 Processor carrier latches Alignment screws Bolster plate This module consists of the heatsink attached to the processor that is already secured in its carrier. Closed-loop liquid cooling heatsink components Closed-loop liquid cooling heatsink components HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 34 The coolant in the liquid cooling module contains anti-corrosion additives which could degrade over time resulting in potential leaks in the system. To protect the system, HPE recommends replacing the module every five years. For additional information, contact your local HPE representative.
  • Page 35: Hpe Ns204I-U Boot Device V2 Components

    HPE NS204i-u Boot Device V2 components Item Description Item Description Boot device cage M.2 slots Boot device carriers HPE NS204i-u Boot Device V2 LED definitions HPE NS204i-u Boot Device V2 LED definitions HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 36: Riser Board Components

    All riser slots are PCIe5 x16 (16, 8, 4, 1) and are rated for a maximum power draw of 75 W each. Primary riser Primary riser This riser board supports Slot 1 and 2 in the three-slot configuration, or Slot 1 in the two-full-height slot configuration. Front: Slot 1 HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 37 Full-height, up to 9.5" (or half-length) Secondary low-profile riser Secondary low-profile riser This riser board supports Slot 3 in the three-slot configuration, and is included in the secondary x16 low-profile riser kit (P48903-B21). HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 38: Riser Slot Numbering

    Setting up the server Operational requirements Operational requirements Rack warnings and cautions Rack warnings and cautions Server warnings and cautions Server warnings and cautions Electrostatic discharge Electrostatic discharge HPE Installation Service Installation Service HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 39: Setting Up The Server

    HPE Installation Service provides basic installation of Hewlett Packard Enterprise branded equipment, software products, as well as HPE- supported products from other vendors that are sold by HPE or by HPE authorized resellers. The Installation Service is part of a suite of HPE deployment services that are designed to give users the peace of mind that comes from knowing that their HPE and HPE-supported products have been installed by an HPE specialist.
  • Page 40: Operational Requirements

    Remotely: connect to the iLO web interface using remote console. a. Verify the following: iLO is licensed to use the remote console feature. If iLO is not licensed, visit the HPE website: https://www.hpe.com/info/ilo https://www.hpe.com/info/ilo The iLO management port is connected to a secure network.
  • Page 41: Space And Airflow Requirements

    To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, climate-controlled environment. The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C (95°F). The temperature in the room where the rack is located must not exceed 35°C (95°F). HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 42: Power Requirements

    Before configuring your rack solution, be sure to check the rack manufacturer weight limits and specifications. Failure to do so can result in physical injury or damage to the equipment and the facility. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 43 You must fully understand the static and dynamic load carrying capacity of the rack and be sure that it can accommodate the weight of the server. Be sure sufficient clearance exists for cabling, installation and removal of the server, and movement of the rack doors. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 44: Server Warnings And Cautions

    Electrostatic discharge Electrostatic discharge Be aware of the precautions you must follow when setting up the system or handling components. A discharge of static electricity from a HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 45 Intel VROC RAID support is disabled by default. In the pre-OS environment, use UEFI System Utilities to enable Intel VROC and create a VROC RAID volume. These tasks are not supported in Intelligent Provisioning. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 46 2. Press the UID button again to close the Server Health Summary screen. Display device setup Display device setup The server supports both VGA port and DisplayPort 1.1a. Before connecting a display device, observe following: Display output modes: HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 47: Trusted Platform Module

    Use the UEFI System Utilities to configure the TPM. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Server Security > Trusted Platform Module options. For more information, see the UEFI user guide: https://www.hpe.com/support/hpeuefisystemutilities-quicklinks https://www.hpe.com/support/hpeuefisystemutilities-quicklinks HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 48: System Battery Information

    Recovery Mode after BitLocker detects a possible compromise of system integrity. HPE is not liable for blocked data access caused by improper TPM use. For operating instructions, see the documentation for the encryption technology feature provided by the operating system.
  • Page 49: Pre-Installation Procedures

    Hewlett Packard Enterprise product QuickSpecs Hewlett Packard Enterprise product QuickSpecs To learn more about your product, search the Hewlett Packard Enterprise website (https://www.hpe.com/info/quickspecs https://www.hpe.com/info/quickspecs) for the product QuickSpecs: Supported options Supported configurations Component compatibility New features Specifications Part numbers Hardware option installation guidelines...
  • Page 50: Power Down The Server

    Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter standby mode. This method forces the server to enter standby mode without properly exiting applications and the OS. If an application stops responding, you can use this method to force a shutdown. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 51: Extend The Server From The Rack

    To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized before extending anything from the rack. Release the cable management arm Release the cable management arm About this task About this task HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 52: Remove The Server From The Rack

    Procedure Procedure 1. Power down the server. 2. Release the cable management arm . 3. Disconnect the cabling from the rear panel. 4. Extend the server from the rack . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 53: Remove The Bezel

    5. Remove the server from the rack: 6. Place the server on a sturdy, level surface. Remove the bezel Remove the bezel Procedure Procedure 1. If installed, remove the Kensington security lock. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 54: Remove The Access Panel

    1. Power down the server. 2. Extend the server from the rack . 3. Open or unlock the locking latch, slide the access panel to the rear of the chassis, and remove the access panel. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 55 3. Disconnect all peripheral cables from the server. 4. Extend the server from the rack . 5. Remove the access panel . 6. Take both sides of the middle cover and detach it from the server. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 56 3. Disconnect all peripheral cables from the server. 4. Remove the server from the rack . 5. Place the server on a flat, level work surface. 6. Remove the access panel . 7. Remove the fans. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 57: Remove The Primary Pcie Riser Cage

    CAUTION CAUTION To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 58 1. Determine the status of the drive from the hot-plug drive LED definitions . 2. Back up all server data on the drive. 3. Remove the drive. Figure 1. SFF drive HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 59 1. Back up all server data. 2. If installed, remove the front bezel . 3. Observe the drive LED status and determine if the drive can be removed. 4. Remove the drive. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 60: Accessing The Systems Insight Display

    The Systems Insight Display is only available in the 8 SFF drive configuration. Procedure Procedure 1. Press and release the panel. 2. After the display ejects, rotate the display to view the LEDs. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 61: Post-Installation Procedures

    Install the server into the rack Power up the server Power up the server Install the primary PCIe riser cage Install the primary PCIe riser cage Procedure Procedure 1. Install the PCI riser cage. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 62 To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge. Procedure Procedure Slide the fan wall to engage with the spools, and then install the screws. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 63 To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge. Procedure Procedure 1. Take both sides of the middle cover and install it on the server. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 64: Install The Access Panel

    Allow the panel to extend past the rear of the server approximately 1.25 cm (0.5 in). 2. Push down on the latch. The access panel slides to a closed position. 3. Tighten the security screw on the latch, if needed. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 65: Install The Server Into The Rack

    A fully populated server is heavy. Hewlett Packard Enterprise recommends removing the external chassis components before installing the server into a rack. Before you perform this procedure, make sure that you have a T-25 Torx screwdriver available. Procedure Procedure 1. Install the server into the rack. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 66 5. Do one of the following: Install the rack rail hook-and-loop strap . Install the cable management arm . 6. Connect each power cord to the power source. 7. Power up the server . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 67: Power Up The Server

    7 high performance fans (dual rotor) 5 standard fans (dual rotor) 7 liquid cooling fans (single rotor) This is supported on servers using the one-processor configuration. Installing a high-performance fan Installing a high-performance fan HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 68 Extend the server from the rack . b. Remove the server from the rack . 4. Remove the access panel . 5. Remove any fan blanks. 6. Remove all standard fans. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 69 Results The installation procedure is complete. Drives Drives Subtopics Subtopics Drive installation guidelines Drive installation guidelines Installing a hot-plug SAS, SATA or NVMe drive Installing a hot-plug SAS, SATA or NVMe drive HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 70: Drive Installation Guidelines

    Procedure Procedure 1. Back up all server data. 2. If installed, remove the front bezel . 3. Remove the drive blank: LFF drive blank HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 71 SFF drive blank 4. Prepare the drive. LFF drive SFF drive 5. Install the drive. LFF drive HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 72 Procedure Procedure 1. Back up all server data. 2. If installed, remove the front bezel . 3. Observe the drive LED status and determine if the drive can be removed. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 73 7. Determine the status of the drive from the drive LED definitions . 8. If removed, install the front bezel . 9. To configure drive arrays, see the relevant storage controller guide . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 74: Drive Cages

    4. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 5. Do one of the following: a. Extend the server from the rack . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 75 7. Remove the access panel . 8. Install the 4 E3.S drive backplane onto the 4 E3.S drive cage. 9. Do one of the following: Install drives. Install drive blanks. 10. Remove the drive box blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 76 15. Install the server in the rack. 16. Connect all peripheral cables to the server. 17. Connect each power cord to the server. 18. Connect each power cord to the power source. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 77 4. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 5. Do one of the following: a. Extend the server from the rack . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 78 7. Install the 2 SFF drive backplane onto the 2 SFF drive cage. 8. Do one of the following: Install drives. Install drive blanks. 9. Remove the access panel . 10. Remove the drive box blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 79 15. Install the server in the rack. 16. Connect all peripheral cables to the server. 17. Connect each power cord to the server. 18. Connect each power cord to the power source. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 80 Extend the server from the rack . b. Remove the server from the rack . 6. Place the server on a flat, level work surface. 7. Remove the universal media bay blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 81 9. Remove the access panel . 10. Connect the power cable to the 8SFF drive backplane . 11. Connect the signal cable . 12. Do one of the following: Install drives. Install drive blanks. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 82 After the battery is installed, it might take up to two hours to charge. Controller features requiring backup power are not re-enabled until the battery is capable of supporting the backup power. This server supports the 96 W HPE Smart Storage Battery with the 145 mm cable. For more information, see HPE Smart Storage Batteries and Hybrid Capacitors QuickSpecs: https://www.hpe.com/psnow/doc/a00028553enw.pdf?jumpid=in_pdp-psnow-qs...
  • Page 83 The capacitor pack can support up to three devices. This server supports the HPE Smart Storage Hybrid Capacitor with the 145 mm cable. Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware requirements to support the capacitor pack.
  • Page 84 Before installing this option, be sure that the power supplies support the installation of this option. In addition, be sure that you have the components included with the hardware option kit. About this task About this task HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 85 6. Remove the primary PCI riser cage. 7. Install the GPU bracket. 8. Install the GPU in the riser cage. If installing a GPU requiring greater than 75W, connect the power cable to the system board. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 86 The Systems Insight Display is supported in the 8 SFF drive configuration. CAUTION CAUTION To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 87 5. Place the server on a flat, level work surface. 6. Remove the access panel . 7. Remove the SID blank. 8. Guide the SID cable through the front of the server. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 88 13. Connect all peripheral cables to the server. 14. Connect each power cord to the server. 15. Connect each power cord to the power source. 16. If removed, install the front bezel . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 89 Extend the server from the rack . b. Remove the server from the rack . 4. Place the server on a flat, level work surface. 5. Remove the access panel . 6. Remove the serial port blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 90 From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > System Options > Serial Port Options > Embedded Serial Port. c. Select a setting. d. Press F12 F12 key to save your selection. e. Click Yes-Save Changes. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 91: Media Devices

    Extend the server from the rack . b. Remove the server from the rack . 5. Place the server on a flat, level work surface. 6. Remove the access panel . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 92 11. Install the server in the rack. 12. Connect each power cord to the server. 13. Connect each power cord to the power source. 14. If removed, install the front bezel . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 93 Extend the server from the rack . b. Remove the server from the rack . 5. Place the server on a flat, level work surface. 6. Remove the LFF optical drive bay blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 94 7. Install the optical drive bracket. 8. Install the optical drive. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 95 The option supports the installation of a slim-type SATA optical drive. CAUTION CAUTION A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive devices. To prevent damage, observe antistatic precautions. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 96 Remove the server from the rack . 5. Place the server on a flat, level work surface. 6. Remove the access panel . 7. Remove the bay blank. 8. Install the 8 SFF display port/USB/optical option. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 97 Install the 8 SFF DisplayPort/USB/optical blank option . Be sure you have the following: The components included with the hardware option kit T-10 Torx screwdriver Phillips No. 1 screwdriver An optical disk drive About this task About this task HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 98 Remove the server from the rack . 5. Place the server on a flat, level work surface. 6. Remove the access panel . 7. Remove the optical drive blank. 8. Install the optical drive bracket. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 99 12. Install the server in the rack. 13. Connect each power cord to the server. 14. Connect each power cord to the power source. 15. Power up the server . Results Results HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 100 Procedure Procedure (Optional) Installing the optical disk drive (Optional) Installing the optical disk drive 1. Remove the optical drive blank. 2. Install the optical drive bracket. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 101 6. Power down the server. 7. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 8. Do one of the following: HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 102 11. Remove the blanks from drive Box 4 and Box 5. 12. Install the DisplayPort / USB / optical blank option. 13. If the optical drive is installed, connect the optical drive cable. 14. Connect the DisplayPort / USB cable . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 103: Dimm Installation Guidelines

    Installing a DIMM HPE SmartMemory speed and population information SmartMemory speed and population information For information about memory speed and server-specific DIMM population rules for HPE servers using Intel Xeon 6 Processors, see the relevant memory technical paper in: https://www.hpe.com/docs/server-memory https://www.hpe.com/docs/server-memory...
  • Page 104 Extend the server from the rack . b. Remove the server from the rack . 4. Remove the access panel . 5. Open the DIMM slot latches. 6. Install the DIMM blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 105: Installing A Dimm

    If not all DIMM slots are populated and a standard or high performance heatsink is installed, install the DIMM blank kit ( 810392-B21). About this task About this task The server supports up to 32 DIMMs. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 106 4. Place the server on a flat, level work surface. 5. Remove the access panel . 6. Open the DIMM slot latches. 7. Install the DIMM. 8. Install the access panel . 9. Install the server in the rack. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 107 CAUTION CAUTION A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive devices. To prevent damage, observe antistatic precautions. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 108 Remove the primary riser cage if installing an OCP network adapter in Slot 14 OCP A. Remove the secondary riser cage or riser blank if installing an OCP network adapter in Slot 15 OCP B. Secondary low-profile riser cage Riser blank HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 109 7. Remove the OCP adapter blank. 8. Install the network adapter. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 110 Review the following: Riser slot numbering Fan and heatsink requirements Before installing this option, be sure that you have the following: The components included with the hardware option kit T-10 Torx screwdriver HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 111 Remove the primary PCI riser cage. b. Remove the blank. c. Install the adapter. To install an adapter in Slot 2 of the primary riser: a. Remove the primary PCI riser cage b. Remove the blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 112 Installing boot device drives Prerequisites Prerequisites Before you perform this procedure, make sure that you have a Phillips No. 1 screwdriver available. Procedure Procedure 1. Push the button to pull out the carrier. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 113 2. Remove the SSD mounting screw. 3. Insert the SSD into the M.2 slot at a 45° angle. 4. Carefully press the SSD down to the horizontal position. 5. Install the SSD mounting screw. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 114 8. Slide the carrier inside the boot device cage and push the button. There will be an audible click when the latch locks into place. Ensure that the latch is fully engaged. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 115 Note the following: The HPE NS204i-u Boot Device V2 is a custom form-factor module that includes two hot pluggable 2280 M.2 NVMe SSDs. HPE NS204i-u Boot Device V2 auto-creates a RAID1 volume during boot, and therefore does not require configuration.
  • Page 116 Installing the boot device in the riser cage 7. Remove the primary riser cage. 8. Remove the slot 2 bracket from the primary riser cage. 9. Install the boot device cage. 10. Install the boot device drives . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 117 11. To install the boot device: a. Install the latch. b. Install the device into the riser cage. c. Install the riser cage. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 118 Installing the internal boot device Installing the internal boot device 12. To install the internal boot device: a. Install the mounting bracket. b. Install the boot device in the server. 4 LFF drive configuration: HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 119 8 SFF drive configuration: 10 SFF / 20 E3.S / mixed drive type configuration: HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 120 17. Connect each power cord to the server. 18. Connect each power cord to the power source. 19. Power up the server. 20. Verify the Online/Activity LEDs on the HPE NS204i Boot Device are solid green . Results Results The installation procedure is complete.
  • Page 121 Note the following: The HPE NS204i-u Boot Device V2 is a custom form-factor module that includes two hot pluggable 2280 M.2 NVMe SSDs. HPE NS204i-u Boot Device V2 auto-creates a RAID1 volume during boot, and therefore does not require configuration.
  • Page 122 9. Install the boot device bracket into the multipurpose cage. 10. Do one of the following: Remove the box blank from Box 5. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 123 If a drive cage is installed in Box 5, remove the drive cage. Box 2 is shown. The removal procedures for all the boxes are the same. 2 SFF drive cage 4 E3.S drive cage HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 124 11. Install the boot device cage into the server. 12. Connect the power and signal cables to the HPE NS204i Boot Device . 13. Install the access panel . 14. Install the server in the rack. 15. Connect all peripheral cables to the server.
  • Page 125: Power Supplies

    19. Verify the Online/Activity LEDs on the HPE NS204i Boot Device are solid green . Results Results The installation procedure is complete. Power supplies Power supplies Subtopics Subtopics Hot-plug power supply calculations Hot-plug power supply calculations Power supply warnings and cautions...
  • Page 126 Switching or disconnecting devices must not be in the earthed circuit conductor between the DC source and the point of connection of the earthing electrode conductor. DC power supply wire colors DC power supply wire colors HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 127: Installing A Redundant Hot-Plug Power Supply

    To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. 2. Access the product rear panel . 3. Remove the blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 128: Installing A Dc Power Supply

    7. Connect the power cord to the AC power source. 8. Be sure that the power supply LED is green . Results Results The installation is complete. Installing a DC power supply Installing a DC power supply HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 129 (The power cable and lug kit listed below can only be used with the 1600 W -48 VDC power supply.) If you are using an input power cord option, the P22173-B21 HPE 1600 W DC PSU power cable kit can be purchased from an authorized HPE reseller.
  • Page 130 Procedure Procedure 1. Remove the protective cover from the power supply. 2. Remove the ground wire screw, and then remove the return wire and line wire screws. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 131 3. Attach the ground wire (green and yellow) to the DC power supply and tighten the screw and washer with 1.47 N-m (13 lbf-in ) . 4. Install the return wire (black): a. Insert the return wire into the RTN slot on the DC power supply. b. Tighten the screw with 0.98 N-m (8.68 lbf-in) . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 132 Insert the line wire into the -48V slot on the DC power supply. b. Tighten the screw to 0.98 N-m (8.68 lbf-in) . 6. Install the protective cover on the DC power supply. Make sure that the protective cover is locked. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 133 8. If you are installing a power supply in the power supply bay 2, remove the power supply blank. Retain the blank for future use. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 134: Connecting A Dc Power Cable To A Dc Power Source

    Connecting a DC power cable to a DC power source Prerequisites Prerequisites Before you perform this procedure, make sure that you have the following items available: Electrical wire cutter Hand crimp tool About this task About this task HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 135 IMPORTANT The minimum nominal thread diameter of a pillar or stud type terminal must be 3.50 mm (0.138 in). The diameter of a screw type terminal must be 5.00 mm (0.197 in). HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 136: Processors And Heatsinks

    Hewlett Packard Enterprise Support Center website (https://www.hpe.com/support/hpesc https://www.hpe.com/support/hpesc). Installing a high performance heatsink Installing a high performance heatsink Prerequisites Prerequisites Review the following: Heatsink and processor socket components Processor cautions Fan and heatsink requirements HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 137 Use a T-30 Torx screwdriver to loosen one pair of diagonally opposite heatsink screws (callouts 1 and 2), and then loosen the other pair of heatsink screws (callouts 3 and 4). 7. Set the anti-tilt wires to the unlocked position. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 138 THE PINS ON THE PROCESSOR SOCKET AND ON THE PROCESSOR ARE VERY FRAGILE AND THE PINS ON THE PROCESSOR SOCKET AND ON THE PROCESSOR ARE VERY FRAGILE AND EASILY DAMAGED. EASILY DAMAGED. Any damage to them might require replacing the system board. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 139 11. Remove the processor from the heatsink: a. Open the TIM breaker lever. This action breaks the adhesion between the processor and the heatsink. b. Hold the processor on its edges, and then remove it from the carrier. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 140 Starting from the pin 1 corner and moving in an opposite manner, disengage the processor carrier release tabs from the heatsink. d. Lift the processor carrier away from the heatsink. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 141 To prevent mechanical damage or depositing oil on your hands or other contaminants to the heatsink contact surface, hold the heatsink only by the edge of its base plate. Do not touch the heatsink fins. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 142 Align the pin 1 indicator on the processor carrier with that on the processor, and then press on the pair of opposite sides on the TIM breaker lever of the processor carrier until it clicks into place. b. Verify that the processor is properly latched on the processor carrier. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 143 If not, press the other pair of opposite sides of the processor carrier until it clicks into place. 16. Attach the heatsink to the processor carrier: a. Align the pin 1 indicator on the processor carrier with that on the heatsink. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 144 There will be an audible click to indicate that the heatsink is properly latched on the processor carrier. 17. Perform the following verification steps: a. Verify that the tabs on the processor carrier are securely latched on the heatsink. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 145 Verify that the pin 1 indicators on the processor and processor carrier are aligned. c. Verity that the processor is properly secured by the carrier snaps. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 146 Carefully lower the processor-heatsink module onto the bolster plate guide posts. The posts are keyed so that the module can only be installed one way. Make sure that the module is properly seated on the bolster plate before securing the screws. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 147 Set the anti-tilt wires to the locked position. e. Tighten one pair of diagonally opposite heatsink screws, and then tighten the other pair of heatsink screws. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 148 About this task About this task For more information about the DLC system, see the HPE Cray XD Direct Liquid Cooling System Site Preparation, User, and Maintenance HPE Cray XD Direct Liquid Cooling System Site Preparation, User, and Maintenance Guide: Guide http://www.hpe.com/info/xdDLCguide...
  • Page 149 The illustrations used in this procedure show an icon on the upper right corner of the image. This icon indicates the type of mounting interface for which the action illustrated in the image is valid. Rack rail options Rack rail options This server supports the following HPE Easy Install friction rack rail (stab-in) options: Server configuration Server configuration Rack rail option...
  • Page 150 Rail number labels on the chassis Rail #3 and #5 Rail identifier stamps on the inner rail of the friction rack rail Rail identifier stamps on the mounting rail of the friction rack rail HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 151: Installing The Rack Rails

    Make sure that the rail option is compatible with the server configuration . If you are installing the server in a threaded round-hole rack, be sure to have a small slotted screwdriver. Procedure Procedure 1. Install the server rails on the server. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 152 The other end of the rails is marked as REAR REAR. 3. Extend the rack rails to align with the depth of the rack. 4. Install the rack rails. For round-hole or square-hole racks: For threaded round-hole racks: HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 153 5. Install the server into the rack . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 154: Installing The Server Into The Rack

    Before you perform this procedure, make sure that you have a T-25 Torx screwdriver available. Procedure Procedure 1. Install the server into the rack. 2. Tighten the shipping screws. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 155: Installing The Rack Rail Hook-And-Loop Strap

    The hook-and-loop strap can be installed on either the left or right rail. Procedure Procedure 1. Attach the strap carabiner to the rail. 2. Bundle the cords and cables, and then wrap the strap around the cables. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 156: Installing The Cable Management Arm

    (Optional) Rotate the bracket. The management arm can be installed to swing out from the left or right side of the rack. Before installing, rotate the elbow bracket according to your configuration. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 157 There will be an audible click to indicate that the bracket is locked in its adjusted position. 3. Install the CMA brackets to the inner and outer rails. 4. Open the straps and cable baskets. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 158 HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 159 Otherwise, the cables might snag on other equipment installed in the rack when the server is extended from or returned to the rack. Install the cables. 6. Close the baskets and secure the straps. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 160 7. Align and install the elbow bracket. Results Results The installation procedure is complete. Risers and riser cages Risers and riser cages HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 161: Primary Pci Riser Cage Options

    Disconnect each power cord from the server. 5. Do one of the following: a. Extend the server from the rack . b. Remove the server from the rack . 6. Remove the access panel . HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 162 Improper grounding can cause electrostatic discharge. 2. Back up all server data. 3. Power down the server. 4. Remove all power: a. Disconnect each power cord from the power source. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 163: Secondary Pci Riser Options

    13. Install the server in the rack. 14. Connect each power cord to the server. 15. Connect each power cord to the power source. 16. Power up the server . Secondary PCI riser options Secondary PCI riser options HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 164 Extend the server from the rack . b. Remove the server from the rack . 5. Place the server on a flat, level work surface. 6. Remove the access panel . 7. Remove the secondary riser blank. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 165 10. Install the server into the rack . 11. Connect each power cord to the server. 12. Connect each power cord to the power source. 13. Power up the server. Results Results The installation procedure is complete. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 166 5. Place the server on a flat, level work surface. 6. Remove the access panel . 7. Remove the primary PCI riser cage. 8. Use a T-10 Torx screwdriver to remove the slot 2 bracket from the primary riser cage. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 167 9. Remove the secondary riser blank. 10. Using a T-15 Torx screwdriver, remove the rear riser support bracket. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 168 11. Install the full-height riser support bracket. 12. Install the riser cage. Primary: HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 169 Secondary: 13. Install the access panel . 14. Install the server in the rack. 15. Connect all peripheral cables to the server. 16. Connect each power cord to the server. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 170: Installing An Expansion Board In The Secondary Riser Cage

    4. Do one of the following: a. Extend the server from the rack . b. Remove the server from the rack . 5. Remove the access panel . 6. Remove the secondary riser: Secondary full-height HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 171 Secondary low-profile 7. Install the expansion board: Secondary full-height a. Remove the blank. b. Using a Torx T-10 screwdriver, install the controller. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 172: Installing The Bezel

    The installation procedure is complete. Security Security Subtopics Subtopics Installing the bezel Installing the bezel Installing the Chassis Intrusion Detection switch option Installing the Chassis Intrusion Detection switch option Installing the bezel Installing the bezel HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 173: Installing The Chassis Intrusion Detection Switch Option

    2. Using a Kensington security lock, lock the bezel. Installing the Chassis Intrusion Detection switch option Installing the Chassis Intrusion Detection switch option Prerequisites Prerequisites Be sure you have the components included with the hardware option kit. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 174 9. Connect all peripheral cables to the server. 10. Connect each power cord to the server. 11. Connect each power cord to the power source. 12. Power up the server . Results Results HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 175: Storage Controllers

    Extend the server from the rack . b. Remove the server from the rack . 5. Remove the access panel . 6. Remove the primary riser cage. 7. Install the controller. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 176 To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge. Procedure Procedure 1. Back up all server data. 2. Power down the server. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 177 Remove the server from the rack . 5. Remove the access panel . 6. Remove the rear wall blank or riser cage. 7. Remove the OCP adapter blank. 8. Install the storage controller. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 178 Front DisplayPort / USB cabling Front DisplayPort / USB cabling Internal boot device cabling Internal boot device cabling OCP bandwidth enablement cabling OCP bandwidth enablement cabling Serial port cabling Serial port cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 179: Cabling Guidelines

    Grip the body of the cable connector. Do not pull on the cable itself because this action can damage the internal wires of the cable or the pins on the port. If a cable does not disconnect easily, check for any release latch that must be pressed to disconnect the cable. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 180: Cabling Diagrams

    4 LFF drive controller cable: Type-p controller in the primary riser P48970-001 4 LFF drive controller cable: Type-o controller in Slot 14 OCP A P48958-001 Storage controller cabling: 8 SFF drive configuration Storage controller cabling: 8 SFF drive configuration — HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 181 2 SFF Box 1 x4 NVMe: Direct attach cable (CPU1) P75568-001 2 SFF Box 1 x4 NVMe: type-p controller cable P75590-001 2 SFF Box 1&2 x4 (x2 BW) NVMe: type-p controller cable P75593-001 HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 182 HPE NS204i-u Boot Device V2 power cable P48956-001 HPE NS204i-u Boot Device V2 signal cable P74839-001 Riser cage HPE NS204i-u Boot Device V2 power cable P54088-001 Riser cage HPE NS204i-u Boot Device V2 signal cable P71913-001 OCP bandwidth enablement cabling OCP bandwidth enablement cabling —...
  • Page 183: Internal Cabling Management

    4 EDSFF drive backplane cabling 2 SFF drive backplane cabling 2 SFF drive backplane cabling Storage controller backup power cabling Storage controller backup power cabling 4 LFF drive backplane cabling 4 LFF drive backplane cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 184 4 LFF box 1: Type-o controller in Slot 14 OCP A Cable part number Cable part number Color Color From From P48958-001 Orange Drive backplane Type-o controller in Slot 14 OCP A HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 185 OCP A 8 SFF box 1 x1 NVMe drive controller cabling: Type-p controller in the primary riser 8 SFF box 1 x1 NVMe drive controller cabling: Type-p controller in the primary riser HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 186 8 SFF x1 NVMe drive + 2 SFF NVMe drive controller cabling: Type-o controller in Slot 14 OCP A 8 SFF x1 NVMe drive + 2 SFF NVMe drive controller cabling: Type-o controller in Slot 14 OCP A HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 187 2 SFF drive backplane Primary type-p controller Port 2 8 SFF x1 NVMe to type-o controller + 2 SFF direct attach 8 SFF x1 NVMe to type-o controller + 2 SFF direct attach HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 188 2 SFF drive backplane MCIO port 1 8 SFF x1 NVMe to type-o controller + 2 SFF NVMe to type-p controller 8 SFF x1 NVMe to type-o controller + 2 SFF NVMe to type-p controller HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 189 Drive Box 5 cabling Drive Box 5 cabling Drive Box 1 cabling Drive Box 1 cabling 4 EDSFF Box 1: Direct attach (unbanlanced, CPU1) 4 EDSFF Box 1: Direct attach (unbanlanced, CPU1) HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 190 Drive backplane port 1 MCIO port 11 P75278-001 Blue Drive backplane port 2 MCIO port 6 4 EDSFF Box 1: Type-p controller in the secondary riser 4 EDSFF Box 1: Type-p controller in the secondary riser HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 191 Secondary type-p controller Port 2 Drive Box 2 cabling Drive Box 2 cabling 4 EDSFF Box 2: Direct attach (unbanlanced, CPU1 & CPU2) 4 EDSFF Box 2: Direct attach (unbanlanced, CPU1 & CPU2) HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 192 Drive backplane port 2 MCIO port 2 Drive Box 3 cabling Drive Box 3 cabling 4 EDSFF Box 3 x4 NVMe: Direct attach (CPU1 & CPU2) 4 EDSFF Box 3 x4 NVMe: Direct attach (CPU1 & CPU2) HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 193 Blue Drive backplane port 2 MCIO port 2 Drive Box 4 cabling Drive Box 4 cabling 4 EDSFF Box 4 x4 NVMe: Direct attach 4 EDSFF Box 4 x4 NVMe: Direct attach HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 194 Drive backplane port 2 Primary type-p controller Port 1 Drive Box 5 cabling Drive Box 5 cabling 4 EDSFF Box 5 x4 NVMe: Direct attach 4 EDSFF Box 5 x4 NVMe: Direct attach HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 195 Cable part number Cable part number Color Color From From P76443-001 Orange Drive backplane port 1 Primary type-p controller Port 2 P75574-001 Blue Drive backplane port 2 Primary type-p controller Port 1 HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 196 Drive Box 5 cabling Drive Box 5 cabling Drive Box 1 cabling Drive Box 1 cabling 2 SFF Box 1 x4 NVMe: Direct attach (CPU1) 2 SFF Box 1 x4 NVMe: Direct attach (CPU1) HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 197 Port 2 2 SFF Box 1&2 x4 (x2 BW) NVMe: type-p controller 2 SFF Box 1&2 x4 (x2 BW) NVMe: type-p controller This configuration uses a type-p controller and a type-o controller. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 198 Cable part number Color Color From From P75317-001 Orange Box 1&2: Drive backplane MCIO port 5 2 SFF Box 1&2 (x2 BW) NVMe: type-o controller 2 SFF Box 1&2 (x2 BW) NVMe: type-o controller HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 199 Type-o controller Port 2 in Slot 14 OCP A Drive Box 2 cabling Drive Box 2 cabling 2 SFF Box 2 x4 NVMe: Direct attach (CPU1) 2 SFF Box 2 x4 NVMe: Direct attach (CPU1) HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 200 Cable part number Color Color From From P75278-001 Orange Drive backplane MCIO port 6 2 SFF Box 1&2 x4 (x2 BW) NVMe: type-o controller 2 SFF Box 1&2 x4 (x2 BW) NVMe: type-o controller HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 201 Color From From P75590-001 Orange Drive backplane Primary type-p controller Port 1 2 SFF Box 1&2 x4 (x2 BW) NVMe: type-p controller 2 SFF Box 1&2 x4 (x2 BW) NVMe: type-p controller HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 202 Box 1&2: drive backplane Primary type-p controller Port 1 Drive Box 3 cabling Drive Box 3 cabling 2 SFF Box 3 x4 NVMe: Direct attach (CPU1) 2 SFF Box 3 x4 NVMe: Direct attach (CPU1) HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 203 Type-o controller Port 1 in Slot 14 OCP A 2 SFF Box 3 x4 NVMe: type-o controller in Slot 15 OCP B 2 SFF Box 3 x4 NVMe: type-o controller in Slot 15 OCP B HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 204 2 SFF Box 3 x4 NVMe: type-p controller MR416i-p / MR216i-p / MR408i-p in Slot 1 Cable part number Cable part number Color Color From From P75590-001 Orange Drive backplane Primary type-p controller Port 1 HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 205 2 SFF Box 4&5 x4 NVMe: Direct attach 2 SFF Box 4&5 x4 NVMe: Direct attach Cable part number Cable part number Color Color From From P75567-001 Orange Drive backplane MCIO port 3 HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 206 Cable part number Color Color From From P75572-001 Orange Drive backplane Primary type-p controller Port 1 2 SFF Box 4 x4 NVMe: type-o controller 2 SFF Box 4 x4 NVMe: type-o controller HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 207 Type-o controller Port 2 in Slot 14 OCP A Drive Box 5 cabling Drive Box 5 cabling 2 SFF Box 5 x4 NVMe: Direct attach (CPU1) 2 SFF Box 5 x4 NVMe: Direct attach (CPU1) HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 208 Cable part number Color Color From From P75278-001 Orange Drive backplane MCIO port 4 2 SFF Box 4&5 x4 (x2 BW) NVMe: type-o controller 2 SFF Box 4&5 x4 (x2 BW) NVMe: type-o controller HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 209 Orange Drive backplane Type-o controller Port 1 in Slot 14 OCP A 2 SFF Box 4&5 x4 (x2 BW) NVMe: type-p controller 2 SFF Box 4&5 x4 (x2 BW) NVMe: type-p controller HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 210: Storage Controller Backup Power Cabling

    Slot 15 OROC storage backup power cable connector Storage controller backup power cabling: type-p storage controller in the primary riser Storage controller backup power cabling: type-p storage controller in the primary riser HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 211: Drive Power Cabling

    Orange Slot 1 primary butterfly riser: storage backup Primary type-p controller: storage backup power connector power cable connector Drive power cabling Drive power cabling 4 LFF backplane power 4 LFF backplane power HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 212 Color Color From From P75566-001 Orange 8 SFF backplane Backplane Box 1 power connector 2 SFF backplane power 2 SFF backplane power This cable is supported in the 8 SFF drive configuration. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 213 This cable is supported in the 10 SFF / 20 E3.S servers or servers that use mixed drive type configuration. Cable part number Cable part number Color Color From From P75316-001 Orange SFF/ EDSFF backplane Backplane Box 1 power connector HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 214 Energy pack cabling: 8 SFF drive configuration Energy pack cabling: 8 SFF drive configuration Cable part number Cable part number Cable color Cable color From From P45618-001 Orange Energy pack Energy pack connector HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 215 From P45618-001 Orange Energy pack Energy pack connector Optical disk drive cabling Optical disk drive cabling 4 LFF drive configuration: optical disk drive cabling 4 LFF drive configuration: optical disk drive cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 216 Cable part number Color Color From From P73776-001 Orange Optical disk drive Internal USB 3.2 Gen1 port Mixed drive type configuration: optical disk drive cabling Mixed drive type configuration: optical disk drive cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 217 Cable part number Color Color From From P73948-001 Orange 4 LFF front display/USB DisplayPort and USB 2.0 port 8 SFF drive configuration: DisplayPort / USB cabling 8 SFF drive configuration: DisplayPort / USB cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 218 Mixed drive type configuration: DisplayPort / USB cabling Cable part number Cable part number Color Color From From P73948-001 Orange Mixed drive type DisplayPort and USB 2.0 port display/USB/ODD Internal boot device Internal boot device cabling cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 219 Cable part number Color Color From From P48956-001 Orange Boot device power connector NS204i-u power connector P74839-001 Blue Boot device signal connector NS204i-u signal connector 8 SFF drive configuration 8 SFF drive configuration HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 220 Boot device power connector NS204i-u power connector P74839-001 Blue Boot device signal connector NS204i-u signal connector Front panel boot device Front panel boot device in the mixed drive type configuration in the mixed drive type configuration HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 221 Boot device power connector NS204i-u power connector P71913-001 Blue Boot device signal connector NS204i-u signal connector OCP bandwidth enablement cabling OCP bandwidth enablement cabling Slot 14 OCP A x16 enablement Slot 14 OCP A x16 enablement HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 222 Cable part number Color Color From From P74889-001 Orange OCP B internal port 1 MCIO port 12 CPU2 to Slot 15 OCP B x8 enablement CPU2 to Slot 15 OCP B x8 enablement HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 223: Serial Port Cabling

    Cable part number Color Color From From P74891-001 Orange OCP B internal port 1 MCIO port 10 P74891-001 Blue OCP B internal port 2 MCIO port 9 Serial port cabling Serial port cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 224 Serial port cabling Serial port cabling Cable part number Cable part number Color Color From From P45623-001 Orange Serial port Serial port cable connector Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 225: Front I/O Cabling

    Front I/O cables are preinstalled in the server. Cable part number Cable part number Color Color From From P71909-002 Orange Right chassis ear Front IO connector Systems Insight Display cabling Systems Insight Display cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 226 Cable part number Color Color From From P48971-001 Orange Systems Insight Display SID connector module Liquid cooling module cabling Liquid cooling module cabling Closed-loop liquid cooling module cabling Closed-loop liquid cooling module cabling HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 227: Configuration Resources

    QuickSpecs (https://www.hpe.com/info/quickspecs https://www.hpe.com/info/quickspecs). Products ordered from HPE Factory Express might have already been configured with some or all the configurations in this chapter. To determine if any additional setup is required, see your HPE Factory Express order. For one-stop access to version-specific software and firmware documentation, including the latest product release notes, see this quick links page: https://www.hpe.com/support/hpeproductdocs-quicklinks...
  • Page 228: Updating Firmware Or System Rom

    Enable policy-based management of server or server group https://www.hpe.com/support/hpe-gl-com-quicklinks https://www.hpe.com/support/hpe-gl-com-quicklinks firmware for distributed server infrastructure Monitor server compliance with a configured firmware baseline Receive automatic iLO firmware updates Receive baseline update alerts Configuring the server Configuring the server HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 229 For servers running HPE OneView, do not use another tool, such as iLO, to delete or change certain settings. For more information about using HPE OneView and iLO to manage the same server, see the iLO user guide at https://www.hpe.com/support/hpeilodocs- https://www.hpe.com/support/hpeilodocs-...
  • Page 230 Managing the HPE NS204i-u Boot Device V2 Managing the HPE NS204i-u Boot Device V2 For more information on supported features and maintenance information for the HPE NS204i-u Boot Device V2 , see the HPE NS204 Boot Device User Guide: https://www.hpe.com/support/NS204-UG https://www.hpe.com/support/NS204-UG...
  • Page 231: Configuring Security

    HPE iLO 7 Security Technology Brief https://www.hpe.com/support/ilo7-security-en https://www.hpe.com/support/ilo7-security-en Configure and use the Server Configuration Lock feature on HPE Server Configuration Lock User Guide for HPE ProLiant servers and Trusted Supply Chain servers and other servers that have the Server HPE Synergy Configuration Lock feature enabled.
  • Page 232: Troubleshooting

    Front panel LED power fault codes Front panel LED power fault codes The following table provides a list of power fault codes, and the subsystems that are affected. Not all power faults are used by all servers. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 233: Troubleshooting Resources

    For Hewlett Packard Enterprise product environmental and safety information and compliance data, including RoHS and REACH, see: https://www.hpe.com/info/ecodata https://www.hpe.com/info/ecodata For Hewlett Packard Enterprise environmental information, including company programs, product recycling, and energy efficiency, see: HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 234: Notices For Eurasian Economic Union

    Фараби даңғ ылы, 77/7, Телефон/факс: +7 727 355 35 50 Manufacturing date: Manufacturing date: The manufacturing date is defined by the serial number. If you need help identifying the manufacturing date, contact tre@hpe.com tre@hpe.com. Turkey RoHS material content declaration Turkey RoHS material content declaration Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur...
  • Page 235: Ukraine Rohs Material Content Declaration

    3,050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr​ (36°F/hr). The upper limit and rate of change might be limited by the type and number of options installed. HPE ProLiant Compute DL360 Gen12 Server User Guide...
  • Page 236: Mechanical Specifications

    40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m (2953 ft) to a maximum of 3,050 m (10,000 ft). The approved hardware configurations for this system are listed in the Extended Ambient Temperature Guidelines for HPE Gen12 Servers: https://www.hpe.com/support/ASHRAEGen12 https://www.hpe.com/support/ASHRAEGen12...
  • Page 237 Subtopics Subtopics HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 1000 W Flex Slot Titanium Hot-plug Power Supply HPE 1000 W Flex Slot Titanium Hot-plug Power Supply...
  • Page 238: Hpe 1600 W Flex Slot Platinum Hot-Plug Low Halogen Power Supply

    Maximum peak power 1000 W at 100 VAC to 127 VAC 1000 W at 200 VAC to 240 VAC HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply Specification...
  • Page 239 HPE 1600 W Flex Slot -48 VDC Hot-plug Power Supply 1600 W Flex Slot -48 VDC Hot-plug Power Supply Specification Specification Value Value Input requirements Input requirements — Rated input voltage -40 VDC to -72 VDC Rated input frequency Nominal input current 45 A DC at -40 VDC input 36.6 A DC at -48 VDC input...
  • Page 240: Support And Other Resources

    You will also receive recommendations and tailored product knowledge to self-solve any issues, as well as streamlined case creation for faster time to resolution when you must create a case. To learn how to add your contracts and products, see https://www.hpe.com/info/add-products-contracts https://www.hpe.com/info/add-products-contracts.
  • Page 241: Customer Self Repair

    IMPORTANT IMPORTANT Access to some updates might require product entitlement when accessed through the Hewlett Packard Enterprise Support Center. You must have an HPE Account set up with relevant entitlements. Customer self repair Customer self repair Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a CSR part needs to be replaced, it will be shipped directly to you so that you can install it at your convenience.
  • Page 242 Feedback button and icons (at the bottom of an opened document) on the Hewlett Packard Enterprise Support Center portal (https://www.hpe.com/support/hpesc https://www.hpe.com/support/hpesc) to send any errors, suggestions, or comments. This process captures all document information. HPE ProLiant Compute DL360 Gen12 Server User Guide...