Measuring the Downstream RF Signal
Figure 4-18
Step 4
Set the input of the upconverter to a digital QAM signal and the output level to the manufacturer's
recommended settings. Typical output amplitudes range from +50 to +58 dBmV, although DOCSIS
specifies +61 dBmV.
Set the spectrum analyzer to view the RF signal at the center frequency you selected for your headend.
Step 5
In this example, the RF center frequency is 699 MHz. Set your span to 20 MHz. Finally, set your channel
spacing and your channel bandwidth to 6 MHz.
If the RF signal is causing an overload condition on the spectrum analyzer input, your analyzer might
display a signal similar to the one shown in
indicates a false reading.
Figure 4-19
If you add attenuation to the input to the spectrum analyzer you can correct the overload condition as
Step 6
shown in
Cisco uBR7200 Series Universal Broadband Router Hardware Installation Guide
4-20
Overloaded Spectrum Analyzer Input
Measuring the RF Signal at the Upconverter Output—Overload Condition