AFF C30 and AFF C60 Systems Install and Maintain
AFF C30/C60 Installation and Setup Workflow
Outlines the steps for installing and setting up AFF C30/C60 storage systems, covering requirements, site prep, hardware, cabling, and configuration.
AFF C30/C60 Preparation for Installation
Details the process of preparing the site, unpacking, and registering the storage system for installation.
AFF C30/C60 Hardware Installation
Procedure for installing the storage system hardware, including rail kits and securing it in the cabinet.
AFF C30/C60 Hardware Cabling
Instructions for connecting storage system controllers to the network and shelves.
AFF C30/C60 Storage System Power-On
Instructions for connecting a laptop via console port, setting IP, and powering on storage controllers.
AFF C30/C60 System Setup and Configuration
Guides on collecting necessary information for cluster configuration, using a setup worksheet.
AFF C30/C60 Hardware Maintenance Overview
Introduces hardware maintenance procedures for AFF C30/C60 system components.
AFF C30/C60 Boot Media Replacement
Outlines the workflow steps for replacing boot media on AFF C30/C60 systems.
AFF C30/C60 Chassis Replacement
Outlines the workflow steps for replacing the chassis of an AFF C30/C60 system.
AFF C30/C60 Controller Replacement
Outlines the workflow steps for replacing a controller in an AFF C30/C60 system.
AFF C30/C60 DIMM Replacement
Guides on locating, removing, and installing DIMMs in the controller.
AFF C30/C60 Drive Replacement
Guides on physically identifying and removing a failed drive from the system.
AFF C30/C60 Fan Module Replacement
Procedure to shut down or take over an impaired controller before replacing a fan module.
AFF C30/C60 I/O Module Management
Covers adding new or replacing failed I/O modules in the storage system.
AFF C30/C60 NV Battery Replacement
Guides on removing the faulty NV battery and installing the replacement.
AFF C30/C60 Power Supply Replacement
Detailed steps for replacing AC and DC Power Supply Units (PSUs) in the controller.
AFF C30/C60 Real-Time Clock Battery Replacement
Guides on removing the faulty RTC battery and installing the replacement.