Connecting Direct Attach Configurations
This section explains how to connect the controller enclosure directly to data hosts.
It shows configurations that support high availability and high performance, and
notes when host port interconnects must be enabled.
The controller enclosure has four host connections, two per controller. Connect FC
cables from host ports on each controller to FC HBAs on data hosts, as shown in the
following figures. To maintain redundancy, connect each data host to both
controller A and controller B.
Caution –
the fiber optic cables. Doing so can degrade performance or render data unavailable.
Note –
section show only relevant details such as host ports. For detailed illustrations
showing all components, see "Hardware Components and LEDs" on page 13.
Figure 3-1 shows a single-controller to a single-port data host configuration.
Figure 3-1 Single-Controller, Direct Attach Connection to One Single-Port Data
42
HP StorageWorks 2012fc Modular Smart Array user guide • March 2008
Fiber optic cables are fragile. Do not bend, twist, fold, pinch, or step on
For clarity, the schematic illustrations of the controllers shown in this
Host