HP 2000fc User Manual page 16

Modular smart array
Hide thumbs Also See for 2000fc:
Table of Contents

Advertisement

Figure 1-2 shows the ports and switches at the back of the controller.
Power switch
Host ports
Figure 1-2 Controller Ports and Switches (Back View)
Table 1-4 describes the ports and switches on the back of the controller.
Table 1-4 Controller Ports and Switches (Back)
Location
Port/Switch
Power and
Power switch
cooling
module
Controller
Host ports
module
Controller
Expansion
module
port
Controller
Ethernet port
module
Controller
CLI port
module
Controller
Service port
module
16
HP StorageWorks 2012fc Modular Smart Array user guide • March 2008
LINK SPEED
LINK SPEED
Service
FC
FC
Port 0
Port 1
DIRTY
CLEAN
CACHE
ACTIVITY
LINK SPEED
LINK SPEED
Service
FC
FC
Port 0
Port 1
DIRTY
CLEAN
CACHE
ACTIVITY
Service port
Description
Toggle, where:
• – is On
• O is Off
4-Gbps FC ports used to connect to data hosts. Each port contains a Small
Form-factor Pluggable (SFP) transceiver. Host port 0 and 1 correspond to
host channel 0 and 1, respectively.
3-Gbps, 4-lane (12 Gbps total) table-routed SAS Out port used to connect
drive enclosures.
10/100BASE-T Ethernet port used for TCP/IP-based out-of-band
management of the RAID controller. An internal Ethernet device provides
standard 10 Mbit/second and 100 Mbit/second full-duplex connectivity.
Micro-DB9 port used to connect the controller enclosure to a local
management host using RS-232 communication for out-of-band
configuration and management.
3.5-mm jack port used by service technicians only.
CLI
10/100 BASE-T
STATUS
CLI
10/100 BASE-T
STATUS
CLI port
Ethernet port
Expansion port

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2012fc

Table of Contents