HP 2000fc User Manual page 15

Modular smart array
Hide thumbs Also See for 2000fc:
Table of Contents

Advertisement

Table 1-3 describes the LEDs on the drive module.
Table 1-3 Drive Module LED Combinations (Front)
Online/Activity
Fault/UID
(green)
(amber/blue)
On
Off
Blinking
Off
irregularly
Off
Amber, blinking
regularly (1 Hz)
On
Amber, blinking
regularly (1 Hz)
Blinking
Amber, blinking
irregularly
regularly (1 Hz)
Off
Amber, solid
Off
Blue; solid
On or blinking
Blue; solid
Blinking regularly
Off
(1 Hz)
Off
Off
Description
The drive is online, but it is not currently active.
The drive is active and operating normally.
Offline; the drive is not being accessed. A predictive
failure alert has been received for this device. Further
investigation is required.
Online; no activity. A predictive failure alert has been
received for this device. Further investigation is
required.
The drive is active, but a predictive failure alert has been
received for this drive. Further investigation is required.
Offline; no activity. A critical fault condition has been
identified for this drive.
Offline. The drive has been selected by a management
application.
The drive is operating normally, and it has been selected
by a management application.
Do not remove the drive. Removing a drive may
terminate the current operation and cause data loss.
The drive is rebuilding.
Either there is no power, the drive is offline, or the drive
is not configured.
Chapter 1 Before You Begin
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2012fc

Table of Contents