Array Performance Features
Table 3
Specification
PCI Express* Host
Data Transfer Rate
Drive Data Transfer
Rate
Maximum
Scatter/Gathers
Maximum Size of I/O
Requests
Maximum Queue
Tags per Drive
Stripe Sizes
Maximum Number of
Concurrent
Commands
Support for Multiple
Initiators
Flexibility
Background Services
Cache Options
Fault Tolerance
Table 4
Specification
Self Monitoring
Analysis and Reporting
Technology (SMART)
support
Drive Replacement
Intel® RAID Controller SASMF8I Hardware User's Guide
®
lists the Intel
RAID Controller SASMF8I array performance features.
Table 3. Array Performance Features
2.5 Gigabit/s per lane
3 Gigabit/s per lane
26 elements
6.4 Mbytes in 64 Kbyte stripes
As many as the drive can accept
64 Kbyte
255
Yes
Drive migration
Rebuild, consistency check, and initialization
Write-back or write-through, read ahead, and non-read ahead
®
lists the Intel
RAID Controller SASMF8I fault tolerance features.
Table 4. Fault Tolerance Features
Detects up to 70% of all predictable disk drive failures and monitors the
internal performance of all motors, heads, and drive electronics.
•
Auto detection of hard drive failure
•
Hot-plug, hot-swap
•
User set rebuild rate
®
Intel
RAID Controller SASMF8I
®
Intel
RAID Controller SASMF8I
13