Download Print this page
KNX Jung 2308.16 REG HE Operating Instructions Manual

KNX Jung 2308.16 REG HE Operating Instructions Manual

Switch actuator / blinds actuator

Advertisement

Quick Links

Switch actuator / blinds actuator
Switch actuator, 4-gang / blinds actuator, 2-gang
Art. No. 2304.16 REG HE
Switch actuator, 8-gang / blinds actuator, 4-gang
Art. No. 2308.16 REG HE
Switch actuator, 16-gang / blinds actuator, 8-gang
Art. No. 2316.16 REG HE
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
Danger of electric shock on the SELV or PELV installation. Do not connect any loads for
SELV, PELV, or FELV together.
For parallel connection of several drives to an output it is essential to observe the
corresponding instructions of the manufacturers, and to use a cut-off relay if necessary.
There is otherwise risk of irreparable damage to the drives.
Use only Venetian blind drives with mechanical or electronic limit switches. Check the
limit switches for correct adjustment. Observe the specifications of the motor
manufacturers. Device can be damaged.
Do not connect any three-phase motors. Device can be damaged.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
(1) Button field for manual operation
(2) Programming button and LEDs
(3) KNX connection
(4) Connection for mains supply
(5) Status LEDs for outputs
(6) Connection for loads
82560023
J:0082560023
Figure 1
1/11
05.08.2013

Advertisement

loading
Need help?

Need help?

Do you have a question about the Jung 2308.16 REG HE and is the answer not in the manual?

Questions and answers

Summarization of Contents

Functionality
System Information
Details KNX compliance, software dependency, and ETS version compatibility.
Intended Use
Specifies applications for switching loads and controlling blinds/shutters.
Product Characteristics
Lists key features like manual operation, scene function, and output disabling.
Switch Operation Characteristics
Defines switch control modes, logic functions, and timing options.
Blinds Operation Characteristics
Details blind control features, position feedback, and safety functions.
Operation and Control
Operating Elements Overview
Identifies and describes manual control buttons and status LEDs on the device.
Status Indication
Explains the meaning of LED states for output status and manual modes.
Operating Modes
Outlines differences between bus operation and manual control modes.
Manual Control Procedures
Covers temporary/permanent manual control, output operation, disabling/enabling.
Priorities for Blinds Operation
Defines the hierarchy of control for blinds (manual, forced, safety, bus).
Installation and Commissioning
Information for Electrically Skilled Persons
General safety and installation advice for qualified personnel.
Fitting and Electrical Connection
Guidelines for mounting the device and connecting power and loads.
Connecting Device Components
Details wiring for KNX bus, mains supply, and switched loads.
Connecting Blind/Shutter Drives
Specific wiring instructions for blind and shutter actuators.
Cover Installation and Removal
Procedures for installing and removing the protective device cover.
Commissioning Process
Steps for measuring operation times and loading application software.
Appendix
Technical Data
Provides specifications for voltage, current, power loss, and dimensions.
Troubleshooting
Diagnoses and solutions for common operational issues.
Accessories
Lists compatible accessories for the switch actuator.
Warranty Information
Details the product warranty and service contact information.