Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Element4 Manuals
Indoor Fireplace
Cupido 50
Manual
Element4 Cupido 50 Manual
Flue calculation
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
page
of
22
Go
/
22
Contents
Table of Contents
Bookmarks
Table of Contents
Preface
Table of Contents
Rules for Flue Gas Discharge
Flue Calculation Example
The Six Questions of Flue Calculation
Example Flue Configuration
Categories
Category 1 (Metric) - Ratio 1:4
Calculation Table Horizontal Terminal (C11)
Calculation Table Vertical Terminal (C31)
Calculation Table Pipe Diameter 150/100
Category 2 (Metric) - Ratio 1:2.5
Calculation Table Horizontal Terminal (C11)
Calculation Table Vertical Terminal (C31) Pipe Diameter 200/130
Category 3 (Metric) - Ratio 1:2
Calculation Table Horizontal Terminal (C11) Pipe Diameter 200/130
Calculation Table Vertical Terminal (C31) Pipe Diameter 200/130
Category 4 (Metric) - Ratio 1:1
Calculation Table Horizontal Terminal (C11) Pipe Diameter 200/130
Calculation Table Vertical Terminal (C31) Pipe Diameter 200/130
Calculation Table Vertical Terminal (C31) Pipe Diameter 150/100
Category 5 (Metric) - Ratio 2:1
Calculation Table Horizontal Terminal (C11) Pipe Diameter 200/130
Calculation Table Vertical Terminal (C31) Pipe Diameter 200/130
Category 1 (Imperial) - Ratio 1:4
Calculation Table Horizontal Terminal (C11)
Calculation Table Vertical Terminal (C31)
Calculation Table Pipe Diameter 6/4
Category 2 (Imperial) - Ratio 1:2.5
Calculation Table Horizontal Terminal
Calculation Table Vertical Terminal
Category 3 (Imperial) - Ratio 1:2
Calculation Table Horizontal Terminal Pipe Diameter 8/5 Inch
Calculation Table Vertical Terminal Pipe Diameter 8/5 Inch
Category 4 (Imperial) - Ratio 1:1
Calculation Table Horizontal Terminal Pipe Diameter 8/5 Inch
Calculation Table Vertical Terminal Pipe Diameter 8/5 Inch
Calculation Table Vertical Terminal (C31) Pipe Diameter 150/100
Category 5 (Imperial) - Ratio 2:1
Calculation Table Horizontal Terminal Pipe Diameter 8/5
Calculation Table Vertical Terminal Pipe Diameter 8/5
3.10.3 Calculation Table Vertical Terminal Pipe Diameter 8/5 Inches
Existing Chimney
Advertisement
Quick Links
Download this manual
Flue Calculation Manual
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the Cupido 50 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Element4 Cupido 50
Indoor Fireplace Element4 Trisore 50e Installation Manual
For all element4 - electric fires (12 pages)
Indoor Fireplace Element4 Bidore 70 Manual
Flue calculation (22 pages)
Indoor Fireplace Element4 Cupido 60 CF Installation Manual
Conventional flue fires (32 pages)
Indoor Fireplace Element4 CUPIDO 60 Installation Manual
(35 pages)
Indoor Fireplace Element4 4 Installation, Operation And Owner's Manual
Direct vent gas fireplace (93 pages)
Indoor Fireplace Element4 Modore 240 User And Installation Manual
(44 pages)
Indoor Fireplace Element4 Direct Vent Gas Fireplace Installation, Operation And Owner's Manual
(92 pages)
Indoor Fireplace Element4 Sirius User And Installation Manual
(36 pages)
Indoor Fireplace Element4 Sky User And Installation Manual
(44 pages)
Indoor Fireplace Element4 Modore 95 Installation Manual
(64 pages)
Indoor Fireplace Element4 Modore 240 Installation Manual
(62 pages)
Indoor Fireplace Element4 Lucius 140 Room Divider Installation Manual
Direct vent (68 pages)
Indoor Fireplace Element4 Modore 140 MKII Installation, Operation And Owner's Manual
(64 pages)
Indoor Fireplace Element4 Sky Nstallation Manual
(60 pages)
Indoor Fireplace Element4 Sky Installation, Operation And Owner's Manual
Direct vent gas fireplaces (64 pages)
Indoor Fireplace Element4 Modore 140 Installation Manual
(32 pages)
Summarization of Contents
Preface
Closed System Fireplaces
Describes Element4's closed system fireplaces and their operation via concentric flues.
Calculation Scheme Overview
Explains the importance of the flue gas terminal meeting requirements and the role of a calculation scheme.
Approved Flue Systems and Power-Fan
Details approved waste material systems and the use of Power-Fans for specific flue configurations.
Flue Gas Discharge Rules
Determine Flue Diameter
Specifies the main rule for flue diameter and exceptions for Element4 fireplaces.
Maximum Flue Lengths
Defines the maximum permitted vertical and horizontal lengths for flue gas discharge.
Understanding Calculation Tables
Explains how to use calculation tables by determining TVL and THL, and the role of bends.
Flue Calculation Example
Six Questions for Flue Configuration
Outlines six key questions to determine the suitability of a desired flue configuration.
Example Flue Configuration Diagram
Illustrates different flue components and their notation for calculation purposes.
Category 1 (Metric) – Ratio 1:4
Calculation Table Horizontal Terminal (C11)
Table for calculating horizontal terminal (C11) flue configurations for Category 1 metric.
Calculation Table Vertical Terminal (C31)
Table for calculating vertical terminal (C31) flue configurations for Category 1 metric.
Calculation Table Pipe Diameter 150/100
Table for reduced flue diameter 150/100 for Category 1 metric vertical terminals.
Category 2 (Metric) - Ratio 1:2.5
Calculation Table Horizontal Terminal (C11)
Table for calculating horizontal terminal (C11) flue configurations for Category 2 metric.
Calculation Table Vertical Terminal (C31)
Table for calculating vertical terminal (C31) flue configurations for Category 2 metric.
Category 3 (Metric) - Ratio 1:2
Calculation Table Horizontal Terminal (C11)
Table for calculating horizontal terminal (C11) flue configurations for Category 3 metric.
Calculation Table Vertical Terminal (C31)
Table for calculating vertical terminal (C31) flue configurations for Category 3 metric.
Category 4 (Metric) – Ratio 1:1
Calculation Table Horizontal Terminal (C11)
Table for calculating horizontal terminal (C11) flue configurations for Category 4 metric.
Calculation Table Vertical Terminal (C31)
Table for calculating vertical terminal (C31) flue configurations for Category 4 metric.
Calculation Table Vertical Terminal (C31) Pipe Diameter 150/100
Table for reduced flue diameter 150/100 for Category 4 metric vertical terminals.
Category 5 (Metric) - Ratio 2:1
Calculation Table Horizontal Terminal (C11)
Table for calculating horizontal terminal (C11) flue configurations for Category 5 metric.
Calculation Table Vertical Terminal (C31)
Table for calculating vertical terminal (C31) flue configurations for Category 5 metric.
Category 1 (Imperial) – Ratio 1:4
Calculation Table Horizontal Terminal (C11)
Table for calculating horizontal terminal (C11) flue configurations for Category 1 imperial.
Calculation Table Vertical Terminal (C31)
Table for calculating vertical terminal (C31) flue configurations for Category 1 imperial.
Category 2 (Imperial) - Ratio 1:2.5
Calculation Table Horizontal Terminal
Table for calculating horizontal terminal flue configurations for Category 2 imperial.
Calculation Table Vertical Terminal
Table for calculating vertical terminal flue configurations for Category 2 imperial.
Category 3 (Imperial) – Ratio 1:2
Calculation Table Horizontal Terminal Pipe Diameter 8/5 inch
Table for horizontal terminal flue configurations with 8/5 inch diameter for Category 3 imperial.
Calculation Table Vertical Terminal Pipe Diameter 8/5 inch
Table for vertical terminal flue configurations with 8/5 inch diameter for Category 3 imperial.
Category 4 (Imperial) - Ratio 1:1
Calculation Table Horizontal Terminal Pipe Diameter 8/5 inch
Table for horizontal terminal flue configurations with 8/5 inch diameter for Category 4 imperial.
Calculation Table Vertical Terminal Pipe Diameter 8/5 inch
Table for vertical terminal flue configurations with 8/5 inch diameter for Category 4 imperial.
Category 5 (Imperial) – Ratio 2:1
Calculation Table Horizontal Terminal Pipe Diameter 8/5
Table for horizontal terminal flue configurations with 8/5 diameter for Category 5 imperial.
Calculation Table Vertical Terminal Pipe Diameter 8/5
Table for vertical terminal flue configurations with 8/5 diameter for Category 5 imperial.
Existing Chimney Installation
Installation Notes and Safety
Provides notes on local rules, flexible pipe requirements, and general safety for chimney installations.
Chimney Requirements and Diagram
Details essential chimney conditions, including cross-sections, cleanliness, and offset allowances.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the Cupido 50 and is the answer not in the manual?
Questions and answers