Page 1
User- and installation manual Modore 240, Tenore 240 WARNING - THE COMBUSTION CHAMBER OF THIS STOVE SHOULD ONLY BE OPENED AND SERVICED BY A REGISTERED GAS INSTALLER (i.e. GAS SAFE REGISTERED ENGINEER[GB]) These instructions should be left with the customer for future reference...
This Manual Covers the following appliances: Modore 240 (E4-14), Tenore 240 (E4-14) Contents GENERAL INFORMATION......................3 Important Safety Notice .........................3 General Fitting Information ....................4 USER INFORMATION........................5 Remote Control Electronic Ignition System RCE GV60 ...............5 INSTALLER INFORMATION......................10 Ventilation ...........................10 General Balanced Flue Notes / Appliance Fireplace installation ........10...
GENERAL INFORMATION Important Safety Notice The engineer will provide you with information about the safety limits of the installation and This appliance has a ceramic Fire-bed arrangement; should fix a notice plate in a place where it can this contains Refractory Ceramic Fibres, which be readily seen.
GENERAL INFORMATION General Fitting Information BS 5440 part 1, BS 5871 part 2 and BS 6891. Inlet pipe connection 8mm compression In the Republic of Ireland the installation must also Chimney requirements Balanced Flue conform to the relevant standards, particularly Flue monitor Permanent Pilot in regard to flue sizing and ventilation.
electronische ontsteking (RCE4 GV60) een aantal extra functies ingesteld worden: - temperatuurweergave in graden USER INFORMATION Celsius of Fahrenheit; Het toestel wordt bediend met een afstandsbe- - tijd; diening (afb.1). Zowel het ontsteken, het regelen Remote control electronic ignition sys- - temperature display in degrees Celsius or - thermostaat functie;...
Page 6
USER INFORMATION INFORMATIE VOOR DE GEBRUIKER MAN position I g n i t e t h e a p p l i a n c e f o l l o w s : By briefly pressing the SET button, you will go Het ontsteken van het toestel gaat als volgt: MAN stand through the following functions:...
Page 7
USER INFORMATION Flame height / standby Time The flame height can be adjusted continuously by The display can indicate time. using the buttons After placing the battery or simultaneously press- (large flame) and By continuing to lower the flame height, the ap- pliance can be set to the standby position;...
Page 8
USER INFORMATION Timer for thermostat function Example Using the timer enables you to set two times per By using the Y TEMP function you can keep the 24 hours for switching on the day temperature day temperature at 20 °C; while and two times per 24 hours for switching on the you use the 4 TEMP function at night to maintain night temperature.
Page 9
USER INFORMATION Replacing the battery Setting times for the timer If the battery is almost empty, the display will To set the timer, proceed as follows: show “BATT”. Set the day and night temperature as described above To replace the battery, proceed as follows: Briefly press the SET button to enter the (P*) Remove the cover at the back side of the remote TIMER position.
INSTALLER INFORMATION the supplier, thus the appliance must only be nstallatIon installed with the original flue system, no others Before beginning the installation, check that the may be used details on the rating plate correspond to the gas type and pressure to which the appliance will be The gas fire, in combination with the concentric connected.
Page 11
INSTALLER INFORMATION control access box, so an appropriate position for Note: A covered passageway should not be the access box need to be determined. treated as a carport. Flues should not be sited in This appliance has adjustable legs, these must a covered passageway between properties.
INSTALLER INFORMATION INFORMATIE VOOR DE INSTALLATEUR Terminal Locations Wall Mounting Locatie afvoer bij wandmontage Dimension Terminal Position Distance (mm) Afmeting Positie uiteinde Afstand (mm) Directly below an opening,air brick, opening window etc. Direct onder een opening, ventilatiesteen, openslaand raam enz. Above an opening,air brick, opening window etc.
INSTALLER INFORMATION Terminal Locations Roof Termination “Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to: A ventilation opening serving an occupied room, a toilet or a bathroom A heating air supply, when the supply flows through an occupied room. A window that can be opened and that is near an occupied room, a toilet or a bathroom.
INSTALLER INFORMATION Concentric Flue Parts Identification The following pages identify the parts that may be used in the Balanced Flue installation of this appliance. The Item number in the table refers to the item number of the part in the Identification pages, this Item number is also the number that will be used to identify parts in the Installation suggestion diagrams.
Page 15
INSTALLER INFORMATION INFORMATIE VOOR DE INSTALLATEUR...
Page 16
INFORMATIE VOOR DE INSTALLATEUR INSTALLER INFORMATION...
Page 17
INFORMATIE VOOR DE INSTALLATEUR INSTALLER INFORMATION...
Page 18
INFORMATIE VOOR DE INSTALLATEUR INSTALLER INFORMATION...
Page 19
INFORMATIE VOOR DE INSTALLATEUR INSTALLER INFORMATION USVK 100 130 REDUCER Ø130 - Ø100 USDHC 130 HORIZONTAL TERMINALØ130...
INSTALLER INFORMATION Vertical Roof Terminations Distance “V” = 1m– 11m (min – max) We recommend using flue reducer USVK to flue dimension 150/100, after 1 meter vertical in 200/130.
Page 22
INFORMATIE VOOR DE INSTALLATEUR INSTALLER INFORMATION Verticale dakdoorvoer met kniestuk voor concentrisch rookkanaal Vertical Roof Mounted Termination with Elbow for Rigid Concentric Flue We recommend using flue reducer USVK to flue dimension 150/100, after 1 meter vertical in 200/130. Distance “H” = 0 - 3m (min – max) Distance “V1”...
Page 23
INFORMATIE VOOR DE INSTALLATEUR INSTALLER INFORMATION Verticale dakdoorvoer met aflopend kniestuk voor concentrisch rookkanaal Vertical Roof Mounted Termination with Angled Elbow for Rigid Concentric Flue We recommend using flue reducer USVK to flue dimension 150/100, after 1 meter vertical in 200/130. Distance “H”...
INSTALLER INFORMATION Installing the controls Electronic Ignition System RCE GV60) This requires no external electrical power to operate. The receiver unit has only one lead. This lead has one single plug. This plug fits into the connector block on the front of the Gas Control unit, the orientation of this plug is important.
Page 25
INSTALLER INFORMATION Fan Flues Installation All Element4 appliances Balanced Flue appliances are approved for the use of Power Fan Flues. The Power Fan Flues use an electric motor to power a ventilation system on the outlet of the flue system. This system enables a longer flue run than is available on a standard system.
INSTALLER INFORMATION Log Arrangements - Only the ceramics supplied with this appliance are to be used. The ceramics must be laid only as shown on this page. Replacement parts are available from your dealer, but should only be installed by a quali- fied installation engineer.
Page 28
INSTALLER INFORMATION Always check if the pilot is clear, no embers have entered the pilot area and the crosslighting is good before the glass is placed. Also the area around the second thermocouple must be clear, so the flames hit the thermocouple.
INSTALLER INFORMATION Gravel Arrangements / Blackstones / Commissioning the appliance Brilliants / Grey Split Ensure that the Grate , is sitting firmly in the base A soundness test MUST be made before the of the fire box, with the long slot in the centre of the installed stove is left with the customer.
Page 30
INSTALLER INFORMATION INSTALLATION TIPS Please read first the general fitting information which one can find on page 4 of this booklet. IMPORTANT INSTALLATION TIPS FALSE CHIMNEY BREAST: The false chimney breast must always be constructed of an non-combustible material; Always ventilate the space above the appliance by means of grills or a comparable alternative with a minimum air supply of 400 cm2;...
INSTALLER INFORMATION Modore 240 Tenore 240 PIN: 0359CN1268 E4-14 Natural Gas Gas Category I3B/P Supply Pressure (mbar) 28-30/37 Nominal Input 22,0 22,0 22,0 (Gross kW) Efficiency Class Pilot Burner 446.0330.24 446.0330.44 446.0330.44 Gas Rate 2,08 0,63 0,63 (max.m3/hr) Burner Pressure...
Page 32
INSTALLER INFORMATION INSTALLATION OF THE GLASS WINDOW a) Remove the windows left, right and bottom. b) Remove the ceramic bands. c) Unscrew the crosshead screws and remove the metal clamps which hold the glan window inplace (top and bottom glan window)
onderhoudsinstructies onderhoudsinstructies SERVICING INFORMATION speciale glasreiniger of een speciale reiniger Hieronder volgt een overzicht van het minimale voor keramische kookplaten. onderhoud dat jaarlijks moet plaatsvinden. Net speciale glasreiniger of een speciale reiniger Hieronder volgt een overzicht van het minimale Troubleshooting servicing instructions als alle overige werkzaamheden aan het toestel voor keramische kookplaten.
TROUBLE SHOOTING "Problem” "Possible cause” "Remedy” A. No transmission 1. The (new) communication code 1. Hold down the reset button of the receiver, until you hear a long beep between receiver and remote control (motor will not run) . Let go of the reset button after the must still be confirmed.
Page 35
TROUBLE SHOOTING “Problem” “Possible cause” “Remedy” F. Electronics keep sparking while the 1. Receiver is damaged. 1. Replace the receiver and confirm the code pilot burner is ignited (remedy 1 at A) 1.1 Measure the voltage, using a 1. Thermocouple does not function. G.
Page 38
TECHNICAL INFORMATION Countries of Destination The following table gives detail of the Countries that these appliances are approved for use within. The tables following immediately on give the technical characteristics of the appliances. Natural ü Austria I2H G20@20mbar ü Belgium I2E+ G20/G25@20/25mbar ü...
TECHNICAL INFORMATION ü I3B/P G30/G31@50mbar Austria ü I3+ G30/G31@28-30/37mbar Belgium ü I3B/P G30/G31@50mbar, I3+ G30/G31@28-30/37mbar CH Switzerland ü I3B/P G30/G31@30mbar CY Cyprus ü I3B/P G30/G31@50mbar, I3+ G30/G31@28-30/37mbar Czech Republic ü I3B/P G30/G31@50mbar DE Germany ü I3B/P G30/G31@30mbar DK Denmark ü I3B/P G30/G31@30mbar Estonia ü...
Element4. Warranty The warranty for your Element4 appliance will be provided by your supplier. In case of complaints, you must always contact him. Your supplier will contact Element4 if necessary. The factory warranty is valid for 24 months after date of purchase.
Page 44
Element4 B.V. Paxtonstraat 23 8013 RP Zwolle September 2014 The Netherlands...