Element4 Direct Vent Gas Fireplace Installation, Operation And Owner's Manual

Advertisement

Quick Links

Element4 B.V.
Paxtonstraat 23
NL-8013 RP Zwolle
The Nederlands
Direct Vent Gas Fireplace
Installation, Operation and Owner's Manual
This manual covers the following appliances for use in North America ONLY:
Trisore 95, Trisore 100H, Trisore 140, Bidore 95, Bidore 100H,
Bidore 140, Lucius 140, Lucius 140 T, Lucius 140 C 1/3,
Lucius 140 C 2/3, Modore 95, Modore 100H, Modore 140,
Optica, Bioptica
1
Element4 Gas Fireplaces
February 2014
EuropeanHome.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Direct Vent Gas Fireplace and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Element4 Direct Vent Gas Fireplace

  • Page 1 Element4 B.V. Paxtonstraat 23 NL-8013 RP Zwolle The Nederlands Direct Vent Gas Fireplace Installation, Operation and Owner’s Manual This manual covers the following appliances for use in North America ONLY: Trisore 95, Trisore 100H, Trisore 140, Bidore 95, Bidore 100H,...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information User Information Speci cations and Dimensions Clearances Gas and Electric Venting Enclosing the Fireplace Fire Media Operating the Fireplace Maintenance Warranty Venting System Installation Instructions Appendix One Massachusetts Certi cation Appendix Two Troubleshooting Flowchart Appendix Three...
  • Page 3: Important Safety Information

    SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Element4 direct vent gas replace appliance. INSTALLER: Leave this manual with the appliance.
  • Page 4 The glass must only be removed by an authorized and/or jurisdiction for gas product installations to determine their quali ed installer. The authorized technician should only speci c requirements for high altitude installations. remove the glass by the use of glass vacuum holders. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 5 1/16” when converted. If greater accuracy is required, use the metric DO NOT USE abrasive cleaners on the panels. DO NOT dimensions. ATTEMPT to clean the glass panels when they are hot. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 6 IMPORTANT SAFETY INFORMATION When enclosing your Element4 replace the use of non-combustible building materials is REQUIRED. Please read and understand the following. COMBUSTIBLE MATERIALS Materials that can catch re and burn are considered combustible. Any material that is made of, or faced with, wood, wood pulp, paper, plastic or any other material that can catch re and burn is considered combustible.
  • Page 7: User Information

    The Element4 replaces are called direct vent replaces and, as such, the intake and exhaust are both handled through the vent pipe. The replace also provides convection air to your room. Figure 1 (below) shows one of the unique features of the Element4 replaces - its use of convection air ow.
  • Page 8: Speci Cations And Dimensions

    WALL ADAPTER SPECIFICATIONS Input Voltage: 120V AC Input Power: Output Voltage: 6V DC Output Current: 500 mA Size: 3.1”H x 2”W x 1.7”D Output Cord Length: 6 Feet Agency Approvals: UL, CSA Figure 2 Wall Adapter Connection (arrow) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 9 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 27¼ 20 ⁄ 2 ⁄ 3 ⁄ 34 ⁄ 39 ⁄ 12½ 10½ 39 ⁄ ⁄ 4 ⁄ TRISORE 95 GLASS 3 SIDES 12½ 13 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 10 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 34 ⁄ 39 ⁄ 1001 39 ⁄ 1001 2 ⁄ 12½ 13 ⁄ 27¼ 24 ⁄ 16 ⁄ 3 ⁄ 10½ BIDORE 95 RIGHT CORNER SHOWN 12½ ⁄ 4 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 11 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 34 ⁄ 41 ⁄ 1052 2 ⁄ 37½ ⁄ 12½ 28 ⁄ 25 ⁄ 16 ⁄ 3 ⁄ 8½ 12½ 4 ⁄ MODORE 95 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 12 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 5 ⁄ 38 ⁄ 41 ⁄ 1050 15 ⁄ 41 ⁄ 1050 ⁄ 4 ⁄ 35 ⁄ 13 ⁄ TRISORE 100H 29 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 13 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 5 ⁄ 38 ⁄ 41 ⁄ 1057 15 ⁄ 39 ⁄ 1005 ⁄ 4 ⁄ 35 ⁄ 13 ⁄ 29 ⁄ BIDORE 100H RIGHT CORNER SHOWN Element4 Gas Fireplaces EuropeanHome.com...
  • Page 14 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 5 ⁄ 39 ⁄ 1000 43½ 1104 15 ⁄ 39 ⁄ 1000 ⁄ 4 ⁄ 35 ⁄ 13 ⁄ 29 ⁄ MODORE 100H Element4 Gas Fireplaces EuropeanHome.com...
  • Page 15 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 50¾ 1288 57 ⁄ 1464 ⁄ 13 ⁄ 12½ 27¼ 24 ⁄ 16 ⁄ 3 ⁄ 10 ⁄ 2 ⁄ 12½ TRISORE 140 GLASS 3 SIDES 10½ 4 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 16 7 ⁄ 50¾ 1288 57 ⁄ 1471 2 ⁄ 55 ⁄ 1419 57 ⁄ 1471 ⁄ 10½ 12½ 4 ⁄ 16 ⁄ 24 ⁄ 27¼ 3 ⁄ BIDORE 140 10 ⁄ LEFT CORNER SHOWN 12½ 13 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 17 Letter Inches Millimeters 7 ⁄ 14 ⁄ 32 ⁄ LUCIUS 140 54 ⁄ 1389 60 ⁄ 1534 55 ⁄ 1420 57 ⁄ 1464 14 ⁄ 2 ⁄ 16 ⁄ 24 ⁄ 27 ⁄ 7 ⁄ ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 18 14 ⁄ LUCIUS 140 C 1/3 RIGHT CORNER SHOWN 22½ 20½ 57 ⁄ 1470 55 ⁄ 1420 ⁄ 2 ⁄ 32 ⁄ 54 ⁄ 1389 60 ⁄ 1534 37½ 16 ⁄ 24 ⁄ 27 ⁄ 7 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 19 LUCIUS 140 C 2/3 RIGHT CORNER SHOWN 39 ⁄ 1000 37 ⁄ 57 ⁄ 1470 55 ⁄ 1420 ⁄ 2 ⁄ 32 ⁄ 54 ⁄ 1389 60 ⁄ 1534 37½ 16 ⁄ 24 ⁄ 27 ⁄ 7 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 20 LUCIUS 140 T 14 ⁄ 14 ⁄ 59 ⁄ 1509 55½ 1409 59 ⁄ 1509 55½ 1409 ⁄ 2 ⁄ 32 ⁄ 53 ⁄ 1370 61 ⁄ 1554 37½ 16 ⁄ 24 ⁄ 27 ⁄ 7 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 21 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 7 ⁄ 34 ⁄ 1288 59 ⁄ 1518 2 ⁄ 55 ⁄ 1418 ⁄ 12½ 28 ⁄ 25 ⁄ 16 ⁄ 3 ⁄ MODORE 140 10 ⁄ 12½ 4 ⁄ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 22 Millimeters 5 ⁄ 34¼ 42 ⁄ 1084 2 ⁄ 32 ⁄ ⁄ 11 ⁄ "/ 814 37 ⁄ 26½ 3 ⁄ 8 ⁄ OPTICA 11 ⁄ 5 ⁄ Element4 Gas Fireplaces EuropeanHome.com " " 127.5 "/ 1084 8"/ 203 "...
  • Page 23 SPECIFICATIONS and DIMENSIONS Letter Inches Millimeters 5 ⁄ 34¼ 42 ⁄ 1084 2 ⁄ 32 ⁄ ⁄ 11 ⁄ "/ 814 37 ⁄ 26½ 3 ⁄ 8 ⁄ BIOPTICA 12 ⁄ 6 ⁄ Element4 Gas Fireplaces EuropeanHome.com " "/ 1084 "...
  • Page 24: Element4 Gas Fireplaces

    Mantel  /  Linteau   :  2”  (5cm) Figure 3. Typical Rating Label A typical rating label is shown in Figure 3. It is attached to every Element4 replace and contains important certi cation information. It must not be removed from the replace.
  • Page 25 SPECIFICATIONS and DIMENSIONS PARTS OF THE FIREPLACE The various parts of the Lucius 140 replace are shown in Figures 4, 5 and 6. These parts are typical of any Element4 replace. Figure 4 Figure 5 shows two Glass Clamps, after some of the Finish Trim is removed.
  • Page 26 Gas Control - is at the end of the Line Set and controls the ow of gas. See Figure 57. Line Set - approximately 51”/1.3 long and is to be unwrapped to allow remote mounting of Gas Control Table 2. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 27: Clearances

    CLEARANCES MINIMUM CLEARANCE TO COMBUSTIBLES The beauty of the Element4 replaces is due largely to the fact that they are NOT zero-clearance replaces. All clearances • The appliance is approved with a minimum clearance to to combustible AND non-combustible materials MUST be combustible materials on all sides of 11”/280...
  • Page 28 Mantels made of non-combustible material are allowed inside these dimensions but they will be subjected to elevated temperatures and may be Figure 7 too hot to touch. A typical completed installation with mantel is shown in Figure 8. Figure 8 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 29 MUST be maintained. Figure 9 Figure 10 shows the minimum distance to combustible materials. 11” 11” 280 mm 280 mm Figure 10 Figure 11 shows the minimum distance to non-combustible materials. 2”/50 mm 2”/50 mm Figure 11 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 30 A typical chase enclosing a Trisore replace (as an example) is shown in Figure 12. Section B-B (plan view) shows the area around the replace in which combustible furnishings are not permitted. Section A-A shows the clearance to NON-combustible materials. See ENCLOSING the FIREPLACE for the dimensions required for the Convection Air Outlet. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 31 (TYPICAL) DETAIL “C” 2” 50 mm Detail C shows how the non-combustible framing above the replace maintains a minimum clearance of 2”/50 This Figure 13 clearance MUST be maintained to ensure safe operation of the replace. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 32 The minimum distance from the bottom of the appliance to the room ceiling is 72”/1830 mm. See Table 3. Convection Air Outlet Minimum Distances Room ceiling to 72” appliance bottom 1830 Room ceiling to top of 1” Convection Air Outlet Table 3 Figure 14. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 33: Gas And Electric

    Table 4 ELECTRICAL REQUIREMENTS The Element4 replaces use a receiver and remote control for their burner operation. The remote control comes with a 9V battery and the receiver is powered by a 120V AC wall adapter, included. This installation must provide an approved 120V AC wall receptacle to be placed within the six foot cord limit of the wall adapter.
  • Page 34: Venting

    Appendix One. Please read, understand and follow these instructions. • Every Element4 replace is shipped with a North American venting adapter. It MUST be the rst piece of venting installed. • All measurements are taken from the center of the vent connector on the top of the replace (see Figure 15) and all con gurations must fall within the acceptable range of the model-speci c diagrams.
  • Page 35 All Bidore, Lucius, Modore, Manufacturer Optica, Bioptica Trisore only DirectVent Pro only DirectVent Pro M&G DuraVent, Inc.* 5” x 8” components 4” x 6 ⁄ ” components Table 5 * Appendix One contains venting installation instructions. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 36 Dimension “V”. See Graph 1. Dimension “V” can vary between 19”/500 minimum to 9’10”/3.0 maximum depending on Dimension “H”. See Graph 1. Note: Con gurations with horizontal terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 37 90° elbow, a total run of 13’1”/4.0 is allowed Example B: If the rise is 3’10”/1168 then the run can be no longer than 12’/3.67 Example C: If the run is 5’ 6”/1.68 then the rise must be at least 2’2”/670 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 38 Dimension “V”. See Graph 2. Dimension “V” can vary between 3’3”/1.0 minimum to 9’10”/3.0 maximum depending on Dimension “H”. See Graph 2. Note: Con gurations with horizontal terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 39 90° elbow, a total run of 13’1”/4.0 is allowed Example B: If the rise is 3’10”/1168 then the run can be no longer than 12’/3.67 Example C: If the run is 5’ 6”/1.68 then the rise must be at least 2’2”/670 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 40 VENTING HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 41 When installing vertical venting with no elbows, dimension “V” must be at least 3’3”/1.0 m minimum and no more than 36’/11.0 m maximum. Note: Con gurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Figure 18. Vertical Terminations with NO elbows Element4 Gas Fireplaces EuropeanHome.com...
  • Page 42 90° elbow up to a maximum of four (4) 90° elbows. Note: Con gurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Figure 19. Vertical Terminations with 90° elbows Element4 Gas Fireplaces EuropeanHome.com...
  • Page 43 45° elbow up to a maximum of eight (8) 45° elbows. Note: Con gurations with horizontal terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Figure 20. Vertical Terminations with 45° elbows Element4 Gas Fireplaces EuropeanHome.com...
  • Page 44 National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada. Chart 1. Termination Heights A second termination may be no closer than 12”/305 . See Figure 36. Figure 21. Multiple Termination Clearance Element4 Gas Fireplaces EuropeanHome.com...
  • Page 45 - Attach the appropriate restrictor to the bottom of the outlet collar as shown in Figure 23. - Re-attach the ba e on Lucius models Attachment bolts (4 of 8) holding the Lucius ba e in place. Figure 23 Figure 24 Figure 22 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 46: Enclosing The Fireplace

    1. Most important, these replaces are NOT zero-clearance replaces. Unlike most others, there is not a metal box around the Element4 replaces. With no metal box there are no louvers to distract your view of the re. We do, however, want the cooling advantage of a metal box.
  • Page 47 (NON-combustible framing ONLY) from the replace and the entire weight of the non-combustible wallboard (see page 6) is carried by the framing. Since most Element4 replaces have two or three sides of glass, the upper wall framing is usually hung from the ceiling or often cantilevered. See Figure 29.
  • Page 48 Bidore 100H 43½”/1105 17 ⁄ ”/448 40 ⁄ ”/1032 Bidore 140 60”/1521 14½”/368 29¼”/742 Trisore 95 43”/1094 4”/102 29¼”/742 Trisore 100H 45 ⁄ ”/1150 17¾”/450 40 ⁄ ”/1032 Trisore 140 61½”/1564 4”/102 29¼”/742 Table 9 Figure 31 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 49 Lucius 140 1/3 62¼”/1582 20½”/519 53¼”/1352 39½”/1002 Lucius 140 2/3 62¼”/1582 37½”/949 53¼”/1352 39½”/1002 Table 10 Figure 32 Rough Opening Dimensions for NON-COMBUSTIBLE Framing Model Figure Lucius 140 R 18 ⁄ ”/464 62¼”/1582 39½”/1002 Table 11 Figure 33 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 50 LOCATING THE CONTROLS The control system for the Element4 replaces consist of three major components; the receiver, the transmitter and the gas control. The transmitter is the remote control by which you operate the replace. The receiver and the gas control are at one end of a 50”/1270...
  • Page 51 ENCLOSING the FIREPLACE One of the tie wraps which secure the line set. Figure 34. Figure 35. Tighten bolt through mounting bosses (at arrows) Fit tab into bracket on BDLE4 Figure 36. Figure 37 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 52 ENCLOSING the FIREPLACE Figure 38 Figure 39 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 53: Fire Media

    Figure 41 Figure 42 shows how the remaining logs are inserted. Finally check the pilot is clear, no embers have entered the pilot area and the burner lighting is good before the glass is replaced. Figure 42 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 54 Position the coals and r cones as shown in Figure 45. Figures 46 and 47 show detail of the positioning of the logs. Finally, check that the pilot is clear, media has entered the pilot area and the burner lighting is good before the glass is replaced. Figure 46 Figure 47 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 55 Figure 48. Ensure that the area inside the ember shield (circled) is left clear. Figure 48 Position the embers, coals and r cones as shown in Figure 49. Figure 49 Figures 50 and 51 show detail of the positioning of the logs. Figure 50 Figure 51 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 56 Figure 52. Place the logs in the order shown in Figures 52 through 61. Ensure that the area inside the ember shield is left clear. Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 Figure 61 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 57 Trisore 140, Bidore 140, Modore 140 and all Lucius models. Figure 66 shows the 2nd thermocouple area kept clear of media on the Trisore 95, Bidore 95, Modore 95, Bioptica and Optica models. Figure 63 Figure 64 Figure 65 Figure 66 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 58: Operating The Fireplace

    Figure 69. Changing the Mode of Operation. Brie y pressing the SET button changes the mode of operation in the following order: Figure 68. Remote Control Man - Temp - Temp - Timer - back to Man Element4 Gas Fireplaces EuropeanHome.com...
  • Page 59 Brie y press SET button for the next burner cycle time. Once all 4 times are set, press OFF to complete the programming. MANUAL KNOB IN MAIN VALVE KNOB ON POSITION IN OFF POSITION ON/OFF SWITCH IN ON POSITION Figure 69. Gas Valve Element4 Gas Fireplaces EuropeanHome.com...
  • Page 60 Since it is a metal replace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction of these metals. The premium materials and build quality of your replace will keep these sounds to a minimum. Figure 70 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 61: Maintenance

    The quantity and location of the clamps vary by model. Remove the retaining bolt(s) holding the glass clamp and then remove the clamp. Figure 72 Remove all of the retaining bolts and clamps holding in the rst piece of glass. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 62 . If there is a second adjoining glass panel slide it against glass panel Step 5. While ensuring that the glass panels are tight and square to each another, tighten the retaining bolt(s) on each clamp NO MORE THAN ½ TURN. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 63 Inspect the external vent cap on a regular basis to make sure that no debris, plants, trees, shrubs are interfering with the air ow. Figure 75. Pilot Burner Detail Element4 Gas Fireplaces EuropeanHome.com...
  • Page 64 MAINTENANCE THERMOCOUPLE MAINTENANCE The Element4 replaces have two thermocouples; one next to the pilot ame and one opposite the pilot burner on the other side of the main burner. The completeness and operation of both must be checked. A quali ed installer must con rm that the thermocouple is in place and not cracked or damaged.
  • Page 65: Warranty

    WARRANTY PRODUCT INSTALLATION RECORD Installer: Please complete this form. Customer: Please retain this information. Purchased From Date of Purchase Installed By Date of Installation Fireplace Serial Number Fuel Type Element4 Gas Fireplaces EuropeanHome.com...
  • Page 66: Venting System Installation Instructions

    APPENDIX ONE Installation Instructions VENTING SYSTEM INSTALLATION INSTRUCTIONS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 67 APPENDIX ONE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 68 Application | Warning | Safety & Installation Precautions Options | Planning Your Installation Horizontal Installation Snorkels Installing Vinyl Siding Stando Installing Counter Flashing Vertical Installation Cathedral Ceiling Installation General Maintenance / Labels Supplemental Canadian Instructions M&G DuraVent Warranty Element4 Gas Fireplaces EuropeanHome.com...
  • Page 69 APPENDIX ONE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 70 APPENDIX ONE ROUND HORIZONTAL TERMINATION CAP SHOWN PIPE SECTION WALL APPLIANCE THIMBLE ADAPTOR ELBOW SQUARE HORIZONTAL TERMINATION CAP SHOWN ROUND CEILING SUPPORT/WALL THIMBLE COVER 90° PIPE ELBOW SECTION PIPE SECTION APPLIANCE ADAPTOR Element4 Gas Fireplaces EuropeanHome.com...
  • Page 71 APPENDIX ONE VERTICAL HIGH WIND TERMINATION CAP SHOWN STORM COLLAR ROOF FLASHING CEILING FIRESTOP ROUND CEILING SUPPORT/WALL THIMBLE COVER CATHEDRAL CEILING PIPE SUPPORT BOX SECTION PIPE SECTION APPLIANCE ADAPTOR Element4 Gas Fireplaces EuropeanHome.com...
  • Page 72 APPENDIX ONE MALE OPTIONAL SCREWS FEMALE CENTER OF HOLE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 73 APPENDIX ONE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 74 APPENDIX ONE WOOD SCREWS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 75 APPENDIX ONE SHEET METAL SCREWS WALL THIMBLE COVER WOOD SCREWS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 76 APPENDIX ONE SNORKEL OPTIONAL DVA-WTU ADJUST AND SECURE TELESCOPING THIMBLE SLEEVES WITH SCREWS 12" MINIMUM SNORKEL WALL THIMBLE COVER 12" MINIMUM ADEQUATE DRAINAGE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 77 ASSEMBLED IN SEQUENCIAL ORDER FASTEN TERMINATION TO ASSEMBLY THROUGH THE HOLES PROVIDED FASTEN THE 4 CORNERS THROUGH THE HOLES PROVIDED ENSURE ASSEMBLY IS PLUMB AND LEVEL CONNECT TO WALL SEAL ALL AS REQUIRED GAPS & SCREWS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 78 APPENDIX ONE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 79 APPENDIX ONE CEILING JOISTS AND FRAME MARK LOCATION 1 1/2" MARK AND WOOD SCRE DRILL FRAMING PLUMB DECORATIVE CEILING JOISTS CEILING AND FRAME SUPPORT COVER 1 1/2" WOOD SCREWS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 80 APPENDIX ONE PIPE EXTENSION PIPE SECTION WALL STRAP/ PLUMBERS 45° TAPE ELBOW 45° ELBOW Element4 Gas Fireplaces EuropeanHome.com...
  • Page 81 APPENDIX ONE DIMENSION "H" OBTAINED FROM TABLE 2 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 82 TERMINATION CAP HIGH WIND VERTICAL SECURE FLASHING TERMINATION WITH NON-HARDENING SEALANT AND ROOFING NAILS STORM COLLAR ROOF FLASHING NAILS ATTIC INSULATION SHIELD REQUIRED CLEARANCE CLEARANCE AS REQUIRED BY APPLIANCE MFG CLEARANCE AS REQUIRED BY APPLIANCE MFG Element4 Gas Fireplaces EuropeanHome.com...
  • Page 83 APPENDIX ONE LEVEL 2' MIN CATHEDRAL BELOW CEILING FINISHED SUPPORT BOX CEILING CUT HOLE 1/8" LARGER THAN SUPPORT BOX CEILING OVERLAP TRIM CATHEDRAL CEILING SUPPORT SCREWS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 84 APPENDIX ONE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 85: General Maintenance

    APPENDIX ONE GENERAL MAINTENANCE Conduct an inspection of the venting system every six months. Recommended areas to inspect are as follows: Element4 Gas Fireplaces EuropeanHome.com...
  • Page 86 DECORATIVE CEILING SUPPORT/WALL THIMBLE COVER 2 PIECE APPLIANCE WALL THIMBLE ADAPTOR PIPE SECTION ROUND, SCONCE OR SQUARE HORIZONTAL TERMINATION CAP DECORATIVE CEILING SUPPORT/WALL THIMBLE COVER 2 PIECE WALL THIMBLE 90° PIPE ELBOW SECTION PIPE SECTION APPLIANCE ADAPTOR Element4 Gas Fireplaces EuropeanHome.com...
  • Page 87 APPENDIX ONE VERTICAL HIGH WIND OR LOW PROFILE TERMINATION CAP STORM COLLAR ROOF FLASHING CEILING FIRESTOP ROUND CEILING SUPPORT/WALL THIMBLE COVER CATHEDRAL CEILING SUPPORT BOX PIPE SECTION PIPE SECTION APPLIANCE ADAPTOR Element4 Gas Fireplaces EuropeanHome.com...
  • Page 88 Manufactured in Vacaville CA and Albany NY Customer Service Support 800-835-4429 707-446-4740 FAX www.duravent.com DirectVent Pro is a registered trademark of the M&G DuraVent, Inc. All rights reserved. Made in the USA. M&G DuraVent is a member of M&G Group. ©2012 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 89: Massachusetts Certi Cation

    Gas Fitters has issued approval number G1-1212-217 for this appliance. The following must be observed when installing the Element4 replaces within the Commonwealth of Massachusetts: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole...
  • Page 90: Appendix Three

    No reaction to transmitter command. Do not coil the ignition cable. Shorten the ignition cable, if possible. Ignition sequence stops, no pilot ame. Replace transmitter batteries. Quality 1.5V Transmitter command is possible. AA alkaline recommended. (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 91 Ensure 2 thermocouple is in the ame. thermocouple is not heated. Check 2 thermocouple wiring. Replace transmitter batteries. Quality 1.5V Receiver batteries low. AA alkaline recommended. Magnet unit drops while motor turns. 3 beeps. NORMAL OPERATION Element4 Gas Fireplaces EuropeanHome.com...
  • Page 92 EUROPEAN HOME a division of Europa Ja, Inc. 376 Washington St. Suite 203 Malden, MA 02148 tel: 781/324-8383 fax: 781/324-8384 www.europeanhome.com IGE4NA023-140205u Element4 Gas Fireplaces EuropeanHome.com...

Table of Contents