This manual does not cover any details concerning equipment connected to the Growatt ( e.g. PV modules). Information concerning the connected equipment is (The exclusion of implied warranties may not apply in all cases under available from the manufacturer of the equipment some statutes, and thus the above exclusion may not apply.)
A warning describes a hazard to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the Growatt equipment and/or other !...
The unit converts the DC current generated by the photovoltaic (PV) modules to grid-compliant alternating current and performs single-phase feed-in into the electricity grid. Growatt 750-3000-S series inverters are built according to all required safety rules. Nevertheless, improper use may cause lethal hazards for Abbreviation for "Direct Current"...
2.3. Safety instruction protection of the system and personnel. The GROWATT Inverters are designed and tested according to international safety requirements; however, certainsafety precautions must be observed when 2.5. Electrical Connection Warnings installing and operating this inverter.
When energy is fed into the public grid, the energy meter spins backwards. Public grid: Energy is fed directly into the public grid. The Growatt is connected to a separate energy meter. The energy produced is compensated at a rate depending on the electric power company .
Product Description Inverter status symbol Indicates inverter operation status The Growatt inverters are grid-tied inverters which convert DC current generated by PV modules into AC current and feed it into the public grid. 3.2. Type label 3.1. Overview The type labels provide a unique identification of the inverter (The type of product, Device-specific characteristics, Certificates and approvals).
0.8le adin g -0 .8 la gg i ng The maximum layers is 11 for Growatt 750-S-3000-S Environmental Protection Ip65 Ip65 Ip65 After long term storage, local installer or service department of GROWATT Rating should perform a comprehensive test before installation. OperationAmbient -25...+60℃ -25...+60℃...
Mount the inverter in such a way that it cannot be touched inadvertently. Though the packaging box of Growatt inverter is durable, please All electrical installations shall be done in accordance with the local and treat the packing box gently and avoid dispose the packing box.
5.2. Selecting mounting location Do not install the inverter near television antenna or any other antennas and antenna cables. Do not install the inverter in living area, the noise caused by the machine may affect on daily life. This is guidance for installer to choose a suitable installation location, to avoid For security reasons, don’t install the inverter in place where the children potential damages to device and operators.
。 Please make sure the inverter is installed at the right place The inverter can’t install close to trunk 5.3. Mounting Inverter 5.3.1. Mounting bracket Ambient dimensions of series inverters There must be sufficient clearance between the individual inverters to In order to avoid electrical shock or other injury, inspect existing ensure that the cooling air of the adjacent inverter is not taken in.
DC and AC Switch. You must provide an AC circuit breaker. If Growatt DC Switch matching, is included in the delivery of the Growatt inverter, it must be used for operating the Hang the inverter on the explosion screw inverter.
2. The grid connection is made using 3 conductors (L, N, and PE),We recommend the following requirements for Growatt 750-S Growatt 1000-S/ Growatt 1500- 6.Finally, insert the AC connection plug into the AC connection receptacle on the S/Growatt 2000-S/Growatt 2500-S/Growatt 3000-S.
Page 16
5.7.3.2. Connecting the PV array (DC) 5.7.3. Connecting the PV array Danger to life due to lethal voltages! Before connecting the PV array, ensure that the DC switch and AC breaker 5.7.3.1. Conditions for DC connection are disconnect from the inverter.Never connect or disconnect the DC connectors under load.
Commissioning 3. Single knock to “set LCD contrast” →Double knock to enter “LCD contrast 2” →Single knock to select the luminance. You also need to wait a few seconds 6.1. Parameters setting after selecting. When the display becomes dark, the change is saved. Users can use sound control function to change the display language and luminance of the display, enable auto-test function and choose utility model.
If the country you want to select is not in the above list, please 6.2. Independent function option directly select VDE0126-1-1. Netherlands select VDE0126-1-1. NOTICE 6.2.1. Country selecting Please finish the country selecting according to the following steps When the PV panels are connected and their output voltage is greater than 70Vdc but the AC grid is not yet connected, inverter will start up automatically.
Page 19
C. G When the selection is successful, the inverter will reboot automatically If you have selected and confirmed an unwanted country neglectful, please contact Growatt for specific software to clear and reset Information again. Wait the test finish, there are 8 levels testing;...
6.3. LCD display Test fail condition: In the lower center of inverter there is the LCD display. We can check inverter running status, etc. on the LCD screen. Items displayed can be changed by knock; Condition Reason Suggestion you can also change some inverter parameters by knock. Test Stop Communication lose or inverter Check the communication or...
ShineNet to monitor the inverter. 6.4.2. WIFI (Optional) Enable auto test function WiFi module (It is available from Growatt.)can be used as an optional monitoring scheme. The ways to install the WIFI modules and to monitor your inverters refer to the WIFI module manual.
1 to 6 inverters. The transmitters transmit the running data collected from photovoltaic ShineNet is a monitoring software applied to monitor Growatt inverters via RS232 inverters to the monitor and display the data onto the monitor screen, including port or Bluetooth module.
Turn on the DC switch, and the inverter will start automatically when the input smartly record your system features. ShineWebBox Provides local storage, easy voltage is higher than 70V. Note:For Growatt 750-S,the start voltage is 50V wireless and TCP/IP configuration, and presents plant data over Internet. 7.2. Shutdown the Inverter Disconnect the line circuit breaker from single phase and prevent it from being reactivated.
LED turns off. If the PV string DC voltage is too low (≤ 60 Vdc) or DC switch open, the inverter will also turn to shutdown Mode Information Note:For Growatt 750-S,the PV low voltage is less than 50V.
10.1 Warnings(W) 10.2 Errors(E) Warnings(W) identify the current status of the Growatt inverter. Warnings do not relate to a fault. When a (W) with a number after it appears in the display, it Errors(E) codes identify a possible equipment failure, fault or incorrect inverter indicates a Warning Code and is usually cleared through an orderly shutdown/re- setting or configuration.
2. Remove all connection cables from the inverter. Model Growatt Growatt Growatt Growatt Growatt Growatt 750-S 1000-S 1500-S 2000-S 2500-S 3000-S Input data(DC) Danger of burn injuries due to hot enclosure parts! Wait 20 minutes before disassembling until the housing Max.
14.2. Download address www.ginverter.com/Download.aspx 13.2. Multi inverters Contact If you have technical problems about our products, contact the GROWATT Serviceline. We need the following information in order to provide you with the necessary assistance: Inverter type Serial number of the inverter...
Need help?
Do you have a question about the 1000-S and is the answer not in the manual?
Questions and answers