  • Page 1 CPX 0 Windlass Product manual Owners Installations, Operation & servicing manual...
  • Page 2: Specifications

    1- Introduction Thank you for choosing Lewmar. Lewmar products are world renowned for their quality, technical innovation and proven performance. With a Lewmar product you will be provided with many years of outstanding service. Product support: Lewmar products are supported by a worldwide network of distributors and Authorised Service Representatives.
  • Page 3: Safety Notice

    Anchors should be independently secured to prevent accidental • Lewmar windlasses are designed and supplied for release. anchor control in marine applications and are not to be used in conjunction with any other use.
  • Page 4: Installation

    • Suitable electrical cable and crimp terminals 4.2 Accessories Use only genuine Lewmar parts and accessories to ensure top performance and eliminate the risk of voiding your warranty. For replacement parts, please visit your dealer or www.lewmar.com 4.3 Gypsy Suitability Gypsies are ideally suited to handling our factory made Rope/Chain combination rodes, which consist of rope spliced to a chain tail.
  • Page 5 6. Lightly coat the shaft with grease and ensure the drive key is in place before assembly to motor/ gearbox. DO NOT use a permanent adhesive/sealant eg.5200 Lewmar CPX 0 ref B10408 iss.2...
  • Page 6 DO NOT use a permanent adhesive/sealant eg.5200 4.8 Loading rope/chain For safety and performance Lewmar recommends the use of matched Lewmar anchor rodes. ⚠ WARNING! Isolate (turn off) the windlass using circuit breaker / isolator. 1. Remove cover.
  • Page 7: Electrical Wiring

    5- Electrical wiring 5.1 Electric cable selection Lewmar recommends the installer source and install cable that meets the requirements of the standards and regulations relevant to the installation and codes of practice. The cable table gives recommended cable sizes based on total length of cable required, from the battery, following the route of the cables to the windlass and back.
  • Page 8 5.5 CPX0 - 500W Wiring diagram using contactor provided (Part No 68000939) Installation instructions are supplied separately with any accessories.
  • Page 9 5.6 CPX0 - 500W Wiring diagram if a contactor box (Part No 68000965) is used Installation instructions are supplied separately with any accessories. Lewmar CPX 0 ref B10408 iss.2...
  • Page 10 5.7 CPX0 - 700W Wiring diagram using contactor provided (Part No 68000937) Installation instructions are supplied separately with any accessories.
  • Page 11 5.8 CPX0 - 700W Wiring diagram if a contactor box (Part No 68000129) is used Installation instructions are supplied separately with any accessories. Lewmar CPX 0 ref B10408 iss.2...
  • Page 12: Operation

    1. Release any anchor locks 2. Insert the Lewmar lever in to the gypsy drive cap. When safe, rotate handle anti-clockwise until anchor pays out, controlling the rate of descent of the anchor with the handle. Once paid out fully tighten gypsy drive cap and remove handle.
  • Page 13 If the rode pile is too close to the underside of the windlass, re-distribute the rode away from directly below the windlass. If the rode gets too close to the underside of the windlass it will cause problems with good rode recovery and may cause damage to the line. Lewmar CPX 0 ref B10408 iss.2...
  • Page 14: Servicing Schedule

    7- Servicing ⚠ WARNING! Isolate the windlass ⚠ WARNING! Ensure rode is adequately using circuit breaker/isolator secured to an independent strong point 7.1 Servicing schedule The service period is determined by the frequency of use. Professional user will need to carry out these opera- tions more often than the weekend user.
  • Page 15: Troubleshooting

    If okay, replace the contactor. • Check the voltage at the motor. If voltage of at least 9 volts is present and the motor does not operate, the motor may be defective. Lewmar CPX 0 ref B10408 iss.2...
  • Page 16: Part List

    9- Part List...
  • Page 17 8mm - 5/16” Gypsy and stripper kit 18(1) 68001123 68001126 6mm -7mm -1/4” Gypsy and stripper kit 20(1) 68001125 12V, 500W MGB and contactor 19(1) 12V, 700W MGB and contactor 17(1) 68001035 65001206 Clutch lever 26 (1) Lewmar CPX 0 ref B10408 iss.2...
  • Page 18: Warranty

    Lewmar shall not be liable in any way for Product failure, permitted by that state or country’s law, shall be limited or any resulting loss or damage that arises from: to a period of one year from the date of purchase by a.
  • Page 19 NOTES Lewmar CPX 0 ref B10408 iss.2...