Thermo Scientific 381 Operating And Maintenance Manual

Thermo Scientific 381 Operating And Maintenance Manual

370 series steri-cycle co2 incubator direct heat with sterilization cycle
Table of Contents

Advertisement

Model 370 Series
Steri-Cycle CO
Incubator
2
Direct Heat with Sterilization Cycle
Operating and Maintenance Manual
7000370 Rev. 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 381 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Section 1 Installation and Start-Up
Control Panel and Keypad Operation
Details the incubator's control panel layout, indicators, and keypad functions for operation.
Installation and Connection Steps
Covers physical setup, filter placement, connecting power, and gas supplies.
Initial Setup and Configuration
Guides through starting the incubator and setting initial operating parameters like temperature and CO2.
Section 2 Calibration
Temperature Calibration
Process for calibrating the incubator's temperature control system using reference instruments.
CO2 Sensor Calibration
Procedures for calibrating both Thermal Conductivity and Infrared CO2 sensors.
Humidity Calibration
Method for calibrating the optional relative humidity sensor for accurate readings.
Section 3 Configuration
Alarm Configuration
Setting and enabling temperature, CO2, and RH alarms for monitoring and alerts.
Filter and Sensor Settings
Configuring HEPA filter replacement reminders and T/C CO2 sensor parameters.
Gas Guard, Display & Communication Options
Setting up Gas Guard, display options, and RS485 communication addresses.
Section 4 Alarms
Temp Controller Failure Alarm
Describes the TMP CTRL ERR alarm and the function of the safety thermostat.
Sensor Fault Alarms
Explains alarms for sensor malfunctions and provides troubleshooting guidance.
Section 5 Routine Maintenance
Cleaning Procedures
Instructions for cleaning the incubator's interior, exterior, glass doors, and humidity pan.
Filter and Component Replacement
Procedures for replacing HEPA filters, power fuses, and air sample filters.
Sterilization Cycle
Details the process, precautions, and phases of the incubator's sterilization cycle.
Section 6 Factory Options
Communication Options
Setup for Remote Alarms and RS485 interface for external monitoring.
Analog Output and Gas Guard
Information on analog output boards and the CO2 Gas Guard system.
Humidity Readout
Explains the optional humidity sensor, its display, and alarm settings.
Section 7 Specifications
Performance Specifications
Key operational parameters: temperature, CO2, and humidity control limits.
Construction and Electrical Specs
Details physical dimensions, materials, electrical requirements, and weight.
Safety and Environmental Specs
Covers safety standards, operating temperature/humidity ranges, and voltage fluctuations.
Section 8 Spare Parts
Spare Parts List
Comprehensive list of part numbers and descriptions for replacement components.
Section 9 Electrical Schematic
Model Schematics
Electrical diagrams for the 370 and 380 series incubators.
Wiring Diagrams and References
Illustrates connections for options and provides a wire reference chart.
Section 10 Warranty Information
Warranty Terms and Coverage
Details the incubator's warranty period, coverage, exclusions, and contact information.
Declaration of Conformity
Product Compliance Information
Documents the incubator's adherence to EU directives and international standards.

Table of Contents

Save PDF