Lexicon 480L Owner's Manual
How to Load Programs
In order to complete system setup, you will have to load
programs into the 480L machines.
Remember that programs are variations of algorithms
with parameters that have been set at the factory.
Prorams are stored in Banks, with a collection of as
many as 10 similar programs stored in each bank.
Select a Bank
In order to select a program, you must first select the
bank in which the program is stored. There are two
ways to select banks:
1.
Press PROG, then press BANK. This puts you in
Program Preview Mode. The bank number flashes to
indicate banks are being previewed, and the display
shows the current bank name and number.
Press BANK repeatedly. The LARC will scroll through
the banks and display their names.
2.
Press PROG, then press BANK, then press one of
the numeric keys (two for double digit bank numbers)
to navigate directly to a specific bank.
Select a Program
Once a bank has been selected, you can view the
programs in that bank without loading them. To do this,
press PROG. The bank display on the LARC will stop
flashing and the program display will begin flashing.
The current program name and number will be dis-
played.
Press PROG repeatedly. The LARC will scroll through
the programs in the selected bank.
2-8
Load a Program
480L programs are loaded by pressing the numeric
button that matches the flashing LARC display.
Press PROG, and then press a numeric button (1-0).
The LARC will flash the message "SETUP LOADED."
You will find that you can navigate between programs
very quickly with this method. For example, enter the
following keystrokes:
PROG BANK
1
PROG
PROG BANK
9
PROG
PROG BANK
7
PROG
PROG BANK
8
PROG
PROG BANK
3
PROG
Once a program is loaded, the 480L will switch from
Program Preview Mode to Machine Operation Mode.
The new program name will be displayed, and the first
page of variable parameters will appear on the LARC.
Detailed information on program parameters is found
in later chapters of this manual.
1
=
Large Hall
7
=
Stereo Parametric EQ
4
=
Dual Rate Chg Sampler
8
=
Indy Corner
1
=
Brick Wall
Need help?