Pentair T Series Instruction Manual
Pentair T Series Instruction Manual

Pentair T Series Instruction Manual

Mclean cooling technology
Hide thumbs Also See for T Series:

Advertisement

Quick Links

RSP Supply Inc. | https://www.rspsupply.com
Pentair Technical Products
2100 Ho man Way
Anoka, MN 55303
+1-763-323-8200
+1-763-576-3200
www.McLeanCoolingTech.com
Rev. C
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx
INSTRUCTION MANUAL
T-Series
Air Conditioner
T43
© 2010 Pentair Technical Products
Protecting Electronics.
Exceeding Expectations.™
P/N 10-1008-145
89056284

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair T Series

  • Page 1 RSP Supply Inc. | https://www.rspsupply.com INSTRUCTION MANUAL T-Series Air Conditioner Protecting Electronics. Exceeding Expectations.™ Pentair Technical Products 2100 Ho man Way Anoka, MN 55303 +1-763-323-8200 +1-763-576-3200 www.McLeanCoolingTech.com Rev. C © 2010 Pentair Technical Products P/N 10-1008-145 89056284 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 2: Table Of Contents

    NOTE: Some of the information in this manual may not apply if a special unit was ordered. If additional drawings for a special unit are necessary, they have been inserted. Contact Pentair Technical Products if further information is required. - 2 - ©...
  • Page 3: Receiving The Air Conditioner

    Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to Pentair Technical Products -- within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier.
  • Page 4: Installation Instructions

    -X will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. DIMENSIONAL DRAWINGS 6K BTU POWER CORD ENCLOSURE AIR IN AMBIENT AIR OUT ALARM WIRES ENCLOSURE AIR OUT AMBIENT AIR IN DRAIN LOCATION - 4 - © 2010 Pentair Technical Products 89056284 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 5: Mounting Cutout Dimensions

    POWER CORD ENCLOSURE AIR IN AMBIENT AIR OUT ALARM WIRES ENCLOSURE AMBIENT AIR OUT AIR IN DRAIN LOCATION MOUNTING CUTOUT DIMENSIONS External Cutout Internal Cutout 89056284 © 2010 Pentair Technical Products - 5 - RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 6: Mounting Gasket Kit

    APPLY GASKET TO AIR CONDITIONER BEFORE MOUNTING TO ENCLOSURE EXTERNAL MOUNT INTERNAL MOUNT (EVAPORATOR SIDE) (EVAPORATOR SIDE) NOTE: ADD STRIP TO EVAPORATOR PAN IF INTERNALLY MOUNTED (INCLUDED) - 6 - © 2010 Pentair Technical Products 89056284 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 7: Components List

    Thermal Expansion Valve 99-0540-39 (cap tube) 10-1040-37 10-1040-38 TTC=8300MRAL20 OR TTC=8300MRAL23 TTC=8300MRAL30 Thermal Overload, Compressor TI=MRA4765-114 OR TI=MRA1706-114 OR TI=MRA4764-114 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 10-1061-16 89056284 © 2010 Pentair Technical Products - 7 - RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 8: Wiring Diagram And Schematic

    CAPACITOR COMPRESSOR HEAD PRESSURE CAPACITOR CONTROL MANUAL AUTOMATIC LIMIT SWITCHES START RELAY COMPRESSOR HEATER FREEZE THERMOSTAT COMPRESSOR ENCLOSURE IMPELLER COOLING HEATING THERMOSTAT THERMOSTAT MALFUNCTION SWITCH - 8 - © 2010 Pentair Technical Products 89056284 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 9: Generic Schematic (Actual Unit Options May Vary)

    FREEZE THERMOSTAT (OPTIONAL) RUN CAPACITOR CONDENSER AIR MOVER WITH HEAD PRESSURE CONTROL OPTIONAL SPEED CONTROL CAPACITOR HARD START RELAY RUN CAPACITOR START CAPACITOR COMPRESSOR AND OVERLOAD 89056284 © 2010 Pentair Technical Products - 9 - RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 10: Temperature Control

    - 10 - © 2010 Pentair Technical Products 89056284 RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 11: How To Remove, Clean Or Install A New Inlet Air Filter

    CAUTION Operation of the air conditioner in areas containing airborne caustics or chemicals can rapidly deteriorate filters, condenser coils, blowers and motors, etc. Contact Pentair Technical Products for special recommendations. Refrigerant Loss Each air conditioner is thoroughly tested prior to leaving the factory to insure against refrigeration leaks. Shipping damage or microscopic leaks not found with sensitive electronic refrigerant leak detection equipment during manufacture may require repair or recharging of the system.
  • Page 12: Trouble Shooting

    (replace control box cover for safety). This will pass the switch in the thermostat. Turn the power on and if both blowers and the compressor come on, the thermostat needs to be replaced. - 12 - © 2010 Pentair Technical Products 89056284 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...
  • Page 13: Symptoms And Possible Causes

    Drain tube kinked Getting water in enclosure Enclosure not sealed (allowing humidity in) Mounting gasket damaged For additional technical support (i.e., amp draw, pressures, temperatures), contact Pentair Technical Products at 800-896-2665. 89056284 © 2010 Pentair Technical Products - 13 - RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 14: Warranty

    Pentair Technical Products warrants that the Goods manufactured by Pentair Technical Products will be free from defects in material and workmanship for a period of one (1) year from the date of shipment by Pentair Technical Products, subject to the following conditions and exclusions: A.
  • Page 15: Limitation Of Liability

    B. All returns to Pentair Technical Products must be securely packed, using original cartons if possible. All returns must have the RMA number visible on the outside of the carton. Pentair Technical Products is not responsible for material damaged in transit. Any refrigerant-bearing Goods must be shipped upright for return.
  • Page 16 RSP Supply Inc. | https://www.rspsupply.com Protecting Electronics. Exceeding Expectations.™ Pentair Technical Products 2100 Ho man Way Anoka, MN 55303 +1-763-323-8200 +1-763-576-3200 www.McLeanCoolingTech.com Rev. C © 2010 Pentair Technical Products P/N 10-1008-145 89056284 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-5818-Hoffman-T430616G100-T-Series-AC-115V-6680-BTU-Outdoor.aspx...

This manual is also suitable for:

T430616g15 seriesT430626g15 seriesT430816g15 seriesT430826g15 seriesT431016g15 seriesT431026g15 series

Table of Contents