T-SERIES
Air Conditioner
t43 Model
INSTRUCTION MANUAL
© 2016 Pentair Equipment Protection
89056284
Rev. G
P/N 10-1008-145

Advertisement

Table of Contents
loading

Summary of Contents for Pentair T430846G402

  • Page 1 T-SERIES Air Conditioner t43 Model INSTRUCTION MANUAL © 2016 Pentair Equipment Protection 89056284 Rev. G P/N 10-1008-145...
  • Page 2: Table Of Contents

    NOTE: Some of the information in this manual may not apply if a special unit was ordered. If additional drawings for a special unit are necessary, they have been inserted. Contact Pentair Equipment Protection if further information is required. IMPORTANT NOTICE • These instructions were authored in English.
  • Page 3: Receiving The Air Conditioner

    Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to Pentair Equipment Protection -- within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier.
  • Page 4: Installation Instructions

    125/57 T431046G4XX 400/460 50/60 3.4/3.0 10100/10500 131/55 140/64 XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. DIMENSIONAL DRAWINGS 6K BTU © 2016 Pentair Equipment Protection 89056284 - 4 -...
  • Page 5: Mounting Cutout Dimensions

    8-10K BTU MOUNTING CUTOUT DIMENSIONS External Cutout Internal Cutout © 2016 Pentair Equipment Protection 89056284 - 5 -...
  • Page 6: Mounting Gasket Kit

    MOUNTING GASKET KIT © 2016 Pentair Equipment Protection 89056284 - 6 -...
  • Page 7: Components List

    TTC=8300MRAL30 Thermal Overload, Compressor 10-1007-79 TI=MRA4765-114 OR TI=MRA1706-114 OR TI=MRA4764-114 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 10-1061-16 10-1061-16 Relay, Phase Monitor 87097986 Relay, Overload 87078326 Contactor, 3-Pole 89102057 Relay, 24 VAC 10-1005-36 © 2016 Pentair Equipment Protection 89056284 - 7 -...
  • Page 8: Wiring Diagram And Schematic

    WIRING DIAGRAM AND SCHEMATIC GENERIC WIRE DIAGRAM (ACTUAL UNIT OPTIONS MAY VARY) 88006097 © 2016 Pentair Equipment Protection 89056284 - 8 -...
  • Page 9: Generic Schematic For 1-Phase Models (Actual Unit Options May Vary)

    GENERIC SCHEMATIC FOR 1-PHASE MODELS (ACTUAL UNIT OPTIONS MAY VARY) GENERIC WIRE DIAGRAM FOR 3-PHASE MODELS (ACTUAL UNIT OPTIONS MAY VARY) © 2016 Pentair Equipment Protection 89056284 - 9 -...
  • Page 10: Temperature Control

    Continued operation under the above conditions can and will damage and shorten compressor life. The air conditioner is available with an easily removable inlet filter to facilitate necessary cleaning. There should be no reason to neglect this necessary maintenance. © 2016 Pentair Equipment Protection 89056284 - 10 -...
  • Page 11: How To Remove, Clean Or Install A New Inlet Air Filter

    CAUTION Operation of the air conditioner in areas containing airborne caustics or chemicals can rapidly deteriorate filters, condenser coils, blowers and motors, etc. Contact Pentair Equipment Protection for special recommendations. REFRIGERANT LOSS Each air conditioner is thoroughly tested prior to leaving the factory to insure against refrigeration leaks. Shipping damage or microscopic leaks not found with sensitive electronic refrigerant leak detection equipment during manufacture may require repair or recharging of the system.
  • Page 12: Trouble Shooting

    (replace control box cover for safety). This will pass the switch in the thermostat. Turn the power on and if both blowers and the compressor come on, the thermostat needs to be replaced. © 2016 Pentair Equipment Protection 89056284 - 12 -...
  • Page 13: Symptoms And Possible Causes

    Drain tube kinked Getting water in enclosure Enclosure not sealed (allowing humidity in) Mounting gasket damaged For additional technical support (i.e., amp draw, pressures, temperatures), contact Pentair Equipment Protection at 800-896-2665. © 2016 Pentair Equipment Protection 89056284 - 13 -...
  • Page 14: Warranty

    Pentair Equipment Protection approval. Pentair Equipment Protection must be notified of a claim in writing not later than fourteen (14) days from the date when Buyer has become aware of such occurrence, or where the defect is such that it may cause damage, immediately, such notice containing a description of how the defect manifests itself.
  • Page 15: Limitation Of Liability

    B. All returns to Pentair Equipment Protection must be securely packed, using original cartons if possible. All returns must have the RMA number visible on the outside of the carton. Pentair Equipment Protection is not responsible for material damaged in transit. Any refrigerant-bearing Goods must be shipped upright for return.
  • Page 16 Pentair Equipment Protection 2100 Ho man Way Minneapolis, MN 55303 USA +1.763.422.2211 +1.763.576.3200 PentairProtect.com © 2016 Pentair Equipment Protection 89056284 Rev. G P/N 10-1008-145...

This manual is also suitable for:

T43T seriesT430816g100

Table of Contents