H3C S5800-32F Installation Manual page 61

S5800 series ethernet switches
Hide thumbs Also See for H3C S5800-32F:
Table of Contents

Advertisement

To ensure normal power supply to S5800-60C-PWR using the RPS1000-A3, pay attention to the
following:
The RPS1000-A3 has two power module slots. Make sure that both slots are inserted with a power
module. If only one power module is used, it may enter the protection state due to over current and
then stop providing power supply to the switch.
Ensure good connections of the two lines between the PSR750-D and the RPS1000-A3; otherwise,
a power module may enter the over-current protection state due to a connection failure and stop
providing power supply to the switch.
Use power cords of H3C to connect the PSR750-D to the RPS1000-A3. Pay attention to the
positive (+) and negative (-) marks on the power cords to avoid connection mistakes.
The RPS1000-A3 connected with the PSR750-D has eight outputs, whereas the RPS connectors
are connected to only two outputs on the RPS1000-A3, namely, OUTPUT1 and OUTPUT2.
Figure 3-37 Remove the protective cover from the PSR750-D
Figure 3-38 Connect the PSR750-D to the RPS1000-A3
3-23