Page 1
LIURTR000_eng-00 Instruction Manual for the use and the maintenance of the Radio Remote Control Original instructions Part D: DCRF13 (Model RTR) Receiving Unit AIR SERIES...
Page 3
THIS PART OF THE MANUAL CONSISTS OF Part D - Information, instructions and warnings for the DCRF13 (Model RTR) Receiving Unit. The Manual consists of Part A – General, Part B – Conformity and Frequencies, Part C – Transmitting Unit, Part D – Receiving Unit, Part E –...
Page 4
It is also the responsibility of the Manufacturer and of the design professionals of the Machine on which the Autec Radio Remote Control is to be installed and used to be certain that the structure, condition, organization and markings of the Machine as installed at the facility is appropriate for and will allow for the safe and reliable use and control of the Machine through the Autec Radio Remote Control interface.
Page 5
Machine operated by or through the Autec Radio Remote Control are fully and properly educated and trained by qualified Personnel in the proper and safe use of the Autec Radio Remote Control and of the Machine, including without limitation complete familiarity...
9.1 Warnings for the Installer .................. 17 9.2 Positioning the antenna ..................18 9.3 Wiring ....................... 19 9.4 At end of installation ..................19 10 Maintenance ......................20 11 Malfunction signalled by the Receiving Unit ............20 12 Decommissioning and disposal ................21 AUTEC LIURTR000_eng-00...
(Part A) of the Manual provided with the Radio Remote Control. Structure of the Instruction Manual The Manual for the use and maintenance of Autec Radio Remote Controls consists of different parts, that altogether form the Manual; the Manual must be read carefully, understood and applied by the Radio Remote Control's Owner, User and by all those Persons that, for any reasons, may operate with the Radio Remote Control or with the Machine where it is installed.
Page 9
Receiving Unit. Usage and maintenance instruction as a whole are to be considered as an integral part both of the Autec Radio Remote Control and of the Machine, system, device or Machinery system where the Radio Remote Control is installed.
Caption and terminology Contact Autec if any of the instructions, symbols, warnings or images are not clear and understandable, or if you have doubts or questions. In this part of the Manual, the terms listed below have the same meaning explained in the...
Regulation for the storage of instructions are described in the paragraph with the same title in the general part: please refer to that part. Intellectual property Restrictions connected to intellectual property are described in the paragraph with the same title in the general part: please refer to that part. AUTEC LIURTR000_eng-00...
Brief product presentation Series, Radio Remote Control and Unit The object of this part of the Manual is the DCRF13 (Model RTR) Receiving Unit of an Autec Air series' Radio Remote Control. Autec Air series' Radio Remote Controls are designed to be used on Machines and provide a command interface to their command and control system, to be used from an appropriate distance and position.
Power supply inputs and solid state commands' outputs STOP contacts protection fuses STOP outputs TNC connector for external antenna Address key (ID internal rx memory) Connector for optional card DIP switches Connector for power supply Power supply protection fuse AUTEC LIURTR000_eng-00...
1kg (2.2lb) Refer to Technical Data Sheet for voltage and current rating of relay commands' outputs in the optional cards. Refer to Technical Data Sheet for voltage and current rating of solid state commands' outputs in the optional cards. LIURTR000_eng-00 AUTEC...
The Receiving Unit is off. The signalling LAMP LED blinks once every 5 The Receiving and Transmitting Unit do not seconds. communicate. The Receiving Unit is ready to receive commands The signalling LAMP LED blinks fast. sent by the Transmitting Unit. LIURTR000_eng-00 AUTEC...
- Observe and comply with all applicable Laws, Regulations and Standards, even local. - Operate the Autec Radio Remote Control only in accordance with this Manual and all of its Parts, and with all Autec warnings and instructions, and with applicable Laws, Regulations and Standards,even local.
- Operate the Machine operated by or through the Autec Radio Remote Control only when he is in a safe condition and can perfectly see the whole Machine's working area. - Immediately inform his supervisors and/or the people in charge for the working place and/or...
The STOP circuit in the Receiving Unit has two contacts connected in series through a wire jumper (Autec standard wiring). If the Machine needs a STOP circuit with two separate contacts (four wires), this bridge can be removed.
The Receiving Unit does not The signalling LAMP LED blinks corresponding outputs. activate the outputs of the fast. commands sent. Check the protection fuse of the STOP contacts and, if needed, replace it. LIURTR000_eng-00 AUTEC...
Decommissioning and disposal Instructions for correct decommissioning and disposal of Radio Remote Controls are described in chapter "Decommissioning and disposal" in "Part A" of the Instruction Manual. Therefore, please refer to that part of the Manual. AUTEC LIURTR000_eng-00...