  • Page 1 Pellet Stove ©2022 CADEL srl | All rights reserved - Tutti i diritti riservati LORD 7/7.0 - SWEET3 7/7.0 - PERLA3 7/7.0, - CRISTAL3 7/7.0 - ONE AIRTIGHT - BEAM AIRTIGHT - ACCENT AIRTIGHT SHARP AIRTIGHT - LEE AIRTIGHT - SOUND3 5/7 UP CHROME 5/7 AIRTIGHT - ROUND 5/7 AIRTIGHT - FLOYD 5.0/7.0 -...
  • Page 2 Stufe a pellet...
  • Page 3: Table Of Contents

    6.10 TILES ASSEMBLY (PERLA 7.0) ......22 SUMMARY 6.11 REMOVAL/ASSEMBLY OF METAL/TILE PROFILES 1 MANUAL SIMBOLOGY ........4 (PERLA 7.0)..............22 2 PACKAGING AND HANDLING ......4 6.12 MOUNTING THE STAND (ACCENT AT) ....23 2.1 PACKAGING .............4 6.13 REMOVAL/ASSEMBLY OF CURVED SIDE PANELS 2.2 REMOVING THE STOVE FROM THE PALLET ....4 (CHROME - SOUND - ROUND - FLOYD) ......23 2.3 STOVE HANDLING............5 6.14 INSTALLATION OF TEE FITTING (EXCLUDING SOUND...
  • Page 4: Manual Simbology

    MANUAL SIMBOLOGY USER AUTHORISED TECHNICIAN (ONLY to interpret or the Stove-manufacturer or the Authorized Technician of Technical Assistance Service approved by the Stove-manufacturer) SPECIALIZED STOVE-REPAIRER CAUTION: READ CAREFULLY THE NOTE CAUTION: DANGER OR IRREVERSIBLE DAMAGE POSSIBILITY • The icons with the stylized figures indicates whom the subject dealt in the paragraph is addressed to (between the User and/ or the Authorized Technician and/or the Specialized Stove-repairer).
  • Page 5: Stove Handling

    STOVE HANDLING Both whether the stove is packed or not it is necessary to observe the following instructions for handling and transporting the stove from its sale point to its installation point and for any future movements: • The stove must be handled with idoneous means paying attention to the existing safety regulations; •...
  • Page 6: Smoke Duct (Smoke Fitting)

    SMOKE DUCT (SMOKE FITTING) The smoke duct is the pipe that connects the appliance to the flue. This smoke fitting must comply in particular with the following requirements: • comply with product standard EN 1856-2; • its cross-section must be of constant diameter and no less than that of the appliance outlet, from the firebox outlet up to the connection in the flue;...
  • Page 7: Chimney Pot

    Fig. 3 - Chimney Flues LEGEND Fig. 3 Chimney flue with insulated stainless-steel pipes Chimney flue on the existing chimney Inspection plug Inspection door • The chimney flue must be provided CE in accordance with EN 1443 regulation. Please find attached an example of label: Fig.
  • Page 8: Maintenance

    Fig. 5 - Anti-wind chimney pots Fig. 6 - Reflux area MAINTENANCE • The fumes extraction pipes (fumes conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an expert stove-repairer, in compliance with current regulations, with the instructions of the stove-manufacturer and the directives of your insurance company.
  • Page 9: Combustible Air Inlet For Sealed-Chamber

    Below 15 kW: Air duct diameter Maximum length (smooth duct) Maximum length (corrugated duct) 50 mm 60 mm 80 mm 100 mm 12 m Above 15 kW: Air duct diameter Maximum length (smooth duct) Maximum length (corrugated duct) 50 mm 60 mm 80 mm 100 mm...
  • Page 10: Examples Of Installation

    EXAMPLES OF INSTALLATION (DIAMETERS AND LENGTHS TO BE SIZED) Fig. 10 - Chimney flue 1. Flue installation with hole for the passage of the pipe increased by: minimum 100mm around the pipe if next to non-flammable parts such as cement, brick, etc.; or minimum 300mm around the pipe (or as required by plate data) if next to flammable parts such as wood etc.
  • Page 11: Installation

    LEGEND Fig. 10 Insulation Possible diameter increase Inspection cap Inspection access panel Air inlet Tee fitting with inspection cap Distance from flammable material (smoke duct plate) Maximum 4 m Minimum 3° slope Distance from flammable material (appliance plate) Reflux area Air ducting The instructions in this chapter refer explicitly to the Italian installation regulation UNI 10683.
  • Page 12: Minimum Distances

    A sealed installation does not consume the room’s oxygen because it draws all the air from the outer environment (if suitably ducted) and makes it possible to install the product in all houses that require a high degree of insulation such as “passive” or “high energy efficiency”...
  • Page 13: Overall Dimensions

    This operation (*) must be performed by a technician qualified to disconnect the combustion product expulsion ducts and their subsequent restoration. For generators connected to the hydraulic system, a connection must be provided between the system itself and the product so that, during extraordinary maintenance, carried out by a qualified technician, it is possible to move the generator 1 by at least 50 cm from adjacent walls without emptying the system (e.g.
  • Page 14 LEGEND Fig. 13 95 cm 47 cm 45,2 cm 17,9 cm 32,4 cm 13,1 cm 20,5 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 14 - General dimensions: PERLA 7 - 7.0 LEGEND Fig. 14 94 cm 52,1 cm 45,6 cm 21,3 cm...
  • Page 15 LEGEND Fig. 15 Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 16 - General dimensions: SHARP AIRTIGHT - LEE AIRTIGHT LEGENDE Fig. 16 Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 17 - General dimensions: SOUND3 5UP - 7UP LEGENDE Fig.
  • Page 16 Fig. 18 - Dimensioni generali: SOUND 5PS - 7PS LEGENDE Fig. 18 Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 19 - General dimensions: CHROME 5-7 AIRTIGHT - ROUND 5-7 AIRTIGHT LEGEND Fig. 19 Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Stufe a pellet...
  • Page 17 Fig. 20 - General dimensions: FLOYD 5.0 - 7.0 LEGEND Fig. 20 Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 21 - General dimensions: ONE/BEAM AIRTIGHT LEGEND Fig. 21 95,2 cm 46 cm 45,2 cm 18,9 cm 31,4 cm 13,6 cm 20,2 cm...
  • Page 18 Fig. 22 - General dimensions: ACCENT AIRTIGHT LEGEND Fig. 22 98,8 cm 46 cm 45,2 cm 18,9 cm 35 cm 13,6 cm 23,7 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 23 - General dimensions: VERA 7 - 7.0 LEGEND Fig.
  • Page 19: Stove Door Removal/Installation

    LEGEND Fig. 23 Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 24 - General dimensions: INDIGO EVO 7 LEGEND Fig. 24 90,7 cm 45,2 cm 45,7 cm 18,2 cm 31,4 cm 12,9 cm 20,2 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm STOVE DOOR REMOVAL/INSTALLATION For some operations (e.g.: side panel assembly and cleaning) you must remove the stove door.
  • Page 20: Removal/Assembly Of The Frame

    REMOVAL/ASSEMBLY OF THE FRAME (SWEET 7.0 - ONE AT - BEAM AT - ACCENT AT - ACCENT K) To assemble the frame, proceed as follows: • Remove the 2 screws at the bottom of the frame (see Fig. 28). • Push the frame upwards and release the teeth (see Fig. 29). •...
  • Page 21: Lee At)

    Fig. 34 - Remove the screws Fig. 35 - Rotate the side panels Fig. 36 - Remove the side panels REMOVAL/ASSEMBLY OF SIDE PANELS (SHARP AT - LEE AT) To disassemble the side panels, proceed as follows: • Unscrew the black rear profile (see Fig. 37) •...
  • Page 22: Tiles Assembly (Perla 7.0)

    Fig. 40 - Remove the screws Fig. 41 - Remove the side panels 6.10 TILES ASSEMBLY (PERLA 7.0) To disassemble the tiles, proceed as follows: • Place the tiles on a worktop and set the tile support above it. • Have the holes of the profile match those of the tiles and apply all the screws (see Fig. 42). •...
  • Page 23: Mounting The Stand (Accent At)

    6.12 MOUNTING THE STAND (ACCENT AT) • Proceed as follows to disassemble the stand: • Lay the stove down on the ground. • Remove the stove’s feet. • Secure the stand with the screws supplied (see Fig. 45). Fig. 45 - Mounting the stand 6.13 REMOVAL/ASSEMBLY OF CURVED SIDE PANELS (CHROME - SOUND - ROUND - FLOYD) To disassemble the side panels, proceed as follows: •...
  • Page 24: 6.15 Installation Of Sharp Airtight Rear Exhaust

    Fig. 48 - Tee fitting Fig. 49 - Tee fitting 6.15 INSTALLATION OF SHARP AIRTIGHT REAR EXHAUST The SHARP stove can be installed also with the rear exhaust. Install the supplied 20° elbow (see Fig. 50) Fig. 50 - SHARP rear exhaust 6.16 INSTALLATION OF THE FUMES OUTLET CONCENTRIC PIPE SHARP/LEE/CRISTAL/ONE/BEAM/ ACCENT/PERLA/SWEET/LORD/VERA/INDIGO Install the concentric pipe Ø...
  • Page 25: Round/Floyd/Sound)

    MODELS CHROME/ROUND/FLOYD/SOUND) The stove is designed to be connected to the flue by means of a concentric hose, through the specific preinstalled fitting. If different requirements make it necessary to withdraw combustion air directly from an outside wall, the air hose can be decoupled from the concentric fitting.
  • Page 26: 6.19 Connection To The External Thermostat

    Fig. 59 - Electric socket with master switch Fig. 60 - Plug connected • Do not use extension cables. • If the feeder cable is damaged, it must be replaced by an authorized technician. • When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall. •...
  • Page 27: Measurement

    • Press the P1 or P2 key to modify the status. • Confirm with the P3 key. • Scroll to MB Output "Mb EScAPE " with key P1 or P2. • Confirm with P3 key. • • Press P1 (temperature setting) and set t-e “t-E” value. The external thermostat is now enabled. 6.21 STOVE CALIBRATION AND DEPRESSION MEASUREMENT This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its proper operation.
  • Page 28: Fume Conduit Cleaning

    All these operations must be planned in time with your Autorized Technical Assistance Service. • After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust. • If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked more frequently.
  • Page 29: Fume Passages Cleaning

    Fig. 67 - Unscrew the side screws Fig. 68 - Unscrew the Cap stopper Fig. 69 - Unscrew FUME PASSAGES CLEANING Clean the fume passages every year. Fig. 70 - Remove the screws Fig. 71 - Remove the inspection cap •...
  • Page 30: Room Fan Cleaning

    Fig. 74 - Clean with pipe cleaner Fig. 75 - Vacuum out the ash • Clean with a pipe cleaner and suction any ash accumulated inside (see Fig. 74 and Fig. 75). ROOM FAN CLEANING Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise. Fig.
  • Page 31: In Case Of Anomaly

    IN CASE OF ANOMALY PROBLEM SOLVING Before of every Authorized Technician intervention, the same Technician has the duty to check if the parameters of the mother board correspond to those of the table you own. In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to avoi irreparable damages! PROBLEM CAUSE...
  • Page 32 PROBLEM CAUSE SOLUTION INTERVENTION Empty hopper Full the hopper. Auger blocked by a foreign object (for Clean the auger. example nails) Bad quality pellets Try other types of pellets. Pellet drop value too Adjust the pellet loading. low "phase 1" The fire extinguish and the stove stops Check if on the...
  • Page 33: Technical Datas

    PROBLEM CAUSE SOLUTION INTERVENTION The stove is at its Ambient The stove is at its minimum value. Increase the desired ambient highest power but temperature temperature. does not heat up. reached. Stove running and display Reached fume outlet The stove runs at minimum. NO PROBLEM! showing "Smoke limit temperature Overteperature"...
  • Page 34: Features

    Fig. 78 - Remove the screws Fig. 79 - Remove the screw FEATURES LORD 7 DESCRIPTION SWEET3 7 PERLA3 7 VERA 7 WIDTH 45,2 cm 47 cm 52,1 cm DEPTH 45,7 cm 45,2 cm 45,6 cm HEIGHT 90,7 cm 95 cm 93,8 cm WEIGHT 55 kg...
  • Page 35 LORD 7.0 DESCRIPTION SWEET3 7.0 PERLA3 7.0 VERA 7.0 WIDTH 45,2 cm 47 cm 52,1 cm DEPTH 45,7 cm 45,2 cm 45,6 cm HEIGHT 90,7 cm 95 cm 93,8 cm WEIGHT 55 kg 56 kg 60 - 67 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,7 kW 2,8 - 7,7 kW 2,8 - 7,7 kW...
  • Page 36 DESCRIPTION CRISTAL3 7 CRISTAL3 7.0 INDIGO EVO 7 WIDTH 47,7 cm 47,7 cm 45 cm DEPTH 45,4 cm 45,4 cm 45,5 cm HEIGHT 91 cm 91 cm 89,5 cm WEIGHT 56 kg 56 kg 59 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,7 kW 2,8 - 7,7 kW 2,8 - 7,7 kW...
  • Page 37 ONE AIRTIGHT LEE AIRTIGHT DESCRIPTION ACCENT AIRTIGHT BEAM AIRTIGHT SHARP AIRTIGHT WIDTH 46 cm 46 cm 46 cm DEPTH 45,2 cm 45,2 cm 45,2 cm HEIGHT 95,2 cm 95,2 cm 98,7 cm WEIGHT 56 kg 56 kg 59 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,7 kW 2,8 - 7,7 kW 2,8 - 7,7 kW...
  • Page 38 SOUND3 5 UP CHROME 5 DESCRIPTION FLOYD 5.0 SOUND 5 PS ROUND 5 WIDTH 50 cm 50 cm 50 cm DEPTH 59 cm 59 cm 59 cm HEIGHT 95 cm 95 cm 95 cm WEIGHT 76 kg 73 kg 65 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 6,1 kW 2,8 - 7,7 kW...
  • Page 39 SOUND3 7 UP CHROME 5 DESCRIPTION FLOYD 7.0 SOUND 7 PS ROUND 5 WIDTH 50 cm 50 cm 50 cm DEPTH 59 cm 59 cm 59 cm HEIGHT 95 cm 95 cm 95 cm WEIGHT 76 kg 73 kg 65 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,7 kW 2,8 - 7,7 kW...
  • Page 40 Rev. 00 - 2023 CADEL srl www.cadelsrl.com 31025 S. Lucia di Piave - TV www.free-point.it Via Marteri della Libertà, 74 - Italy www.pegasoheating.com Tel. +39.0438.1520200...