Advertisement

Quick Links

INSTRUCTION AND
MAINTENANCE MANUAL
M / M65 H ACD / M100 H ACD
Depureco Industrial Vacuums Srl
Company under the direction and coordination of COFISE S.p.A.
Via Venezia, 32 - 10088 Volpiano (TO), Italy
Tel.
+39 011 98.59.117
Fax
+39 011 98.59.326
TRANSLATION OF ORIGINAL INSTRUCTIONS
www.depureco.com
depureco@depureco.com
depureco@documentipec.com Registered in the
tax code- and VAT reg no.
02258610357 -
Turin Company Register -
R.E.A.
WEEE
register with no. IT18090000010711
SERIES
Share capital:
€ 25,000 fully paid up
TO-1149668

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M65 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DEPURECO M65

  • Page 1 INSTRUCTION AND MAINTENANCE MANUAL M / M65 H ACD / M100 H ACD SERIES TRANSLATION OF ORIGINAL INSTRUCTIONS Depureco Industrial Vacuums Srl Company under the direction and coordination of COFISE S.p.A. www.depureco.com tax code- and VAT reg no. Share capital:...
  • Page 3 INDEX INFORMATION SECTION 1.1. Introduction 1.2. Identification of the main parts 1.3. Optional parts 1.4. Manufacturer’s identification data 1.5. Identification plate 1.6. Intended uses 1.7. Permitted environmental conditions 1.8. Noise level 1.9. Technical data 1.10. Warranty SAFETY SECTION 2.1. Information regarding safety 2.2. Safety requirements 2.3. Plates and safety symbols 2.4.
  • Page 5: Declaration Of Conformity

    DECLARATION OF COMPLIANCE The manufacturer: DEPURECO INDUSTRIAL VACUUMS S.r.l. – Via Venezia, 32 – 10088 Volpiano (TO) – ITALY | Phone. +39 011 98 59 117 – Fax + 39 011 98 59 326 – Tax code. | VAT REG. NO.
  • Page 7: Information Section

    1.1. INTRODUCTION Dear Customer, Thank you for choosing DEPURECO. We hope you will enjoy using your new M65 / M100 / M65 H ACD / M100 H ACD series vacuum cleaner. We have prepared this manual so that you can appreciate the quality of this machine.
  • Page 8 Substances of Very High Concern (SVHC) included in the Candidate List This manual can be accessed via the QR code on the vacuum cleaner or via the website www.depureco.com. Alternatively, contact the manufacturer Depureco. This manual must be available to all vacuum cleaner operators and maintenance staff The Court of Turin (Italy) has jurisdiction for all disputes.
  • Page 9 1.2. IDENTIFICATION OF THE MAIN PARTS M65 JC M100 M100 JC M65 H ACD M100 H ACD M65 TAN JC M100 TAN JC 1. Head with on/off commands 2. Filter chamber 3. Suction inlet 4. Dust/Debris bin 5. Lever for releasing and hooking the bin 6.
  • Page 10: Manufacturer's Identification Data

    1.3. OPTIONAL PARTS Based on the application of the vacuum cleaner, a wide range of other optional accessories is available from DEPURECO 1.4. MANUFACTURER’S IDENTIFICATION DATA Depureco Industrial Vacuums S.r.l. Via Venezia, 32 - 10088 Volpiano (TO), Italy tel: +39 011 98 59 117 fax: +39 011 98 59 326 VAT Reg. No. 02258610357 e-mail: depureco@depureco.com - website: www.depureco.com 1.5.
  • Page 11: Permitted Environmental Conditions

    The work environment must be clean and appropriately lit. 1.8. NOISE LEVEL The phonometric tests carried out on this specific model of vacuum cleaner show a sound pressure level of Machine Noise level M65 - M65 JC - M65 TAN JC 72 dB(A) M100 - M100 JC - M100 TAN JC 72 dB(A) M65 H ACD 72 dB(A)
  • Page 12: Technical Data

    1.9. TECHNICAL DATA Unit of M100 M65 JC M100 JC measurement Weight [kg] Dimensions [mm] 660 x 800 660 x 800 660 x 800 660 x 800 Height [mm] 1300 1515 1300 1515 Power supply [V] - [Hz] 230 - 50/60 230 - 50/60 230 - 50/60 230 - 50/60 voltage/Frequency Power [W]-[HP] 3900 - 5,2...
  • Page 13 ○ ○ ○ M100 ● ○ ○ M65 JC ● ○ ○ M100 JC ● ○ ○ M65 TAN JC ● ○ ○ M100 TAN JC ● ○ ● M65 H ACD ● ○ ● M100 H ACD ● = filter supplied with the vacuum cleaner ○...
  • Page 14: Warranty

    DEPURECO is not liable for any damages to people or property caused by poor or imperfect use of the vacuum cleaner. The Court of Turin (Italy) has jurisdiction for all disputes.
  • Page 15: Safety Section

    Adequate training is a fundamental requirement. DEPURECO will not be held liable for any accidents or damages resulting from the vacuum cleaner being used by untrained staff or being used improperly, or from failure to observe, even partially, the accident prevention regulations and intervention procedures in this manual.
  • Page 16 For ATEX versions and models, to use hoses with earth wire that is not anti-static (an anti-static surface alone is not permitted). • Always use original DEPURECO accessories. Use an ohmmeter to check electrical continuity: • between the suction inlet and the terminal of suction accessories: the resistance measured must be less than 100MΩ (for ATEX versions and models)
  • Page 17 This manual must always be available for consultation on the expected operating cycle and whenever any doubts arise. If it is lost or damaged, you must ask DEPURECO for a replacement copy. M65 H ACD - M100 H ACD • Observe the safety regulations applicable to the materials to be processed.
  • Page 18 Clean them with a cloth, soap and water. Do not use solvents, naphtha or petrol. Replace damaged plates asking DEPURECO for new ones. If a plate is on a part being replaced, make sure that a new plate is affixed to the new part. This sticker indicates that the device can vacuum dust up to class M.
  • Page 19 It is strictly forbidden to take the safety plates off the vacuum cleaner and/or its components and off the packaging. DEPURECO disclaims any liability for the safety of the vacuum cleaner in the event of failure to comply with this prohibition.
  • Page 20: Residual Risks

    2.4. RESIDUAL RISKS DEPURECO recommends strictly following the instructions, procedures, recommendations in this manual and the current safety standards. Furthermore, DEPURECO recommends using the protective devices provided, both those built into the vacuum cleaner and personal ones. With this in mind, the residual risks analysed on the vacuum cleaner and/or on its components can be: Electrical risks when carrying out maintenance due to the need to operate with live voltage Pursuant to Italian Legislative Decree 81/08 - articles from 80 to 87 - it is forbidden to operate with live voltage, except under the exceptions provided for by said decree.
  • Page 21 The following instructions also indicate the operations to be carried out if the vacuum cleaner needs to be repacked or unpacked for subsequent transport. Packaging dimensions: [cm] M65 - M65 JC - M65 TAN JC [cm] M100 - M100 JC - M100 TAN JC [cm]...
  • Page 22 ATTENTION! Depureco is not liable for any damage caused to the machine during lifting if the appropriate equipment is not used. ATTENTION! In the event of subsequent transport, the vacuum cleaner must be anchored to the support platform using a locking system similar to the previously described one.
  • Page 23: Installation

    If any of the components are damaged, it is essential not to continue with installation but to report the anomaly found to Depureco and reach an agreement on the actions to be carried out. The machine is supplied with the filtering unit already installed.
  • Page 24 ATTENTION! Do not push the plug into the socket with wet hands. Extension leads are prohibited. Before plugging the vacuum cleaner into the power socket, make sure that: • The power cable is undamaged and in perfect condition. • The voltage of the power supply line corresponds to the voltage indicated on the nameplate of the vacuum cleaner.
  • Page 25: Operation Section

    4. OPERATION SECTION 4.1. DESCRIPTION OF THE CONTROLS ATTENTION! Before using the vacuum cleaner, it is necessary to comply with section 2.2, “Safety requirements”. ATTENTION! Only authorised staff who have read these use and maintenance instructions are allowed to use the vacuum cleaner. The appliance user and the maintenance technician who carry out the permitted operations on the vacuum cleaner must receive appropriate information and training, as required by current laws on safety in the workplace, and wear the personal protective equipment (PPE) provided for the different operations, such...
  • Page 26: Work Cycle

    Any improper use or action is avoided. • Safety devices are not removed or tampered with. • Regular maintenance work is carried out. • Machine parts (attachments, holes, etc.) must not be modified for any reason to fit additional devices. • Only use original Depureco spare parts. • Avoid rolling or bending the hose while vacuuming. If dust is escaping from the vacuum cleaner head, the filter may have broken. In this case, the vacuum cleaner should be stopped immediately.
  • Page 27 Wait for the motors to come to a complete stop. • Lift and then lower vigorously the lever to shake the inner filter. M65 JC - M100JC - M65 TAN JC - M100 TAN JC The vacuum cleaners in the "JC" and "TAN JC"models, are equipped with the JetClean® cleaning system. The system works thanks to the difference in pressure between the internal atmosphere and the external atmosphere leading to the dust becoming detached from the filtering fabric of the cartridge, without needing to switch the vacuum cleaner off.
  • Page 28 Open and quickly release the JetClean® valve (Item 8 section 1.2) and repeat this operation a couple more times. • Lower the shutter and resume normal use SP CLEANING SYSTEM - OPTIONAL M65 - M100 Cleaning is carried out automatically and continuously while the filter is in use. For information on the use and maintenance of the PN 2-12 cyclic sequencer shown in the figure, please refer to the dedicated manual.
  • Page 29: All Models

    ALL MODELS If the vacuum cleaner does not work properly after the filter has been cleaned, the main filter may need replacing (see dedicated chapter). If the vacuum does not significantly improve after replacing the filter, it means that another issue may be present (see chapter “If something doesn't work”) CAUTION! Never use the machine if the filter is clogged. ATTENTION! If dust is escaping from the silencer, the filter may have broken. In this case, it is necessary to immediately switch off the vacuum cleaner and verify the cause. 4.5. EMPTYING THE CONTAINER ATTENTION! The container/Endless Bag must not only be emptied when full, but also at the end of each use and before the vacuum cleaner is transported. During this operation, use the appropriate PPE (gloves, dust mask, goggles, etc.).
  • Page 30 ENDLESS BAG SYSTEM - OPTIONAL M65 - M100 - M65 JC - M100 JC - M65 TAN JC - M100 TAN JC The material is collected inside a robust plastic bag called an Endless Bag that is 20 metres long. The bag is rolled underneath the chamber and can be adapted to any requirement. The operator, once the bag is filled, can...
  • Page 31 4.6. INSERTING AND LOCKING THE CONTAINER Insert and lock the container as follows: • Place it under the vacuum cleaner while holding the lever up and push until it reaches the stops. • The “A” pins on both sides must be aligned with “B” the slots. •...
  • Page 32 ENDLESS BAG - OPTIONAL M65 - M100 - M65 JC - M100 JC - M65 TAN JC - M100 TAN JC To replace the Endless bag, proceed as follows: • Turn off the machine. • Rotate the hooks under the filter chamber to unlock the bag’s support ring. • Pull out the ring and remove the last portion of the bag.
  • Page 33: Maintenance Section

    5. MAINTENANCE SECTION ATTENTION! Extraordinary maintenance of the vacuum cleaner may only be carried out by specialised technicians approved by the DEPURECO dealer. 5.1. INFORMATION NOTES The utmost reliability of the vacuum cleaner and the minimum maintenance cost are due to a planned maintenance and inspection program that is meticulously followed throughout the entire service life of the vacuum cleaner.
  • Page 34 Before each work shift: • Check that the power cable and plug are undamaged: replace immediately if there are signs of wear and tear, using a cable of the same type (information c/o DEPURECO); this is the exclusive responsibility of an electrician. • Ensure that the safety symbols (pictograms) affixed to the vacuum cleaner are intact. • Make sure that the debris container is empty and locked under the vacuum cleaner.
  • Page 35 Switch off the machine by turning the switch from I to O. • Disconnect the vacuum cleaner from the power supply. M65 - M100 - M65 H ACD - M100 H ACD • Remove the container as described in section 4.5.
  • Page 36 Remove the vacuum’s head and place it on a work bench. • Slip out the filter (D) and place it on a work bench. • Loosen the fastening clip (E), remove the filter from its support. • With scissors cut the lower belts that clamp it to the filter’s cage. ATTENTION! Use appropriate lifting straps for the total weight of the motor base. M65 JC - M100 JC - M65 TAN JC - M100 TAN JC • Unlock the “C” hooks on the sides of the head base on the filter chamber.
  • Page 37 ALL MODELS ATTENTION! Remove the filter, put it in a plastic bag, close it and dispose of it according to the laws in force for the type of material vacuumed. USE ONLY DEPURECO ORIGINAL FILTERS! TO MOUNT THE NEW FILTER, REVERSE THE STEPS PREVIOUSLY DESCRIBED SP CLEANING SYSTEM - OPTIONAL M65 - M100 ATTENTION! Wear appropriate PPE (dust mask, latex gloves, goggles, etc.).
  • Page 38 • Unlock the “C” hooks on the sides of the head base on the filter chamber. • Remove the cap and place it on a work bench. • Unlock the SP cleaning system from the “A” locking hooks. • Using an “H” eye bolt (not included in the supply) with GAS threading and a male G1 connection (screw the eye bolt into the threaded hole on the upper face of the “I”...
  • Page 39 Remove and unscrew the nuts (I) from the base of the cartridges. • Pull out and replace the filter cartridges ATTENTION! Remove the filter, put it in a plastic bag, close it and dispose of it according to the laws in force for the type of material vacuumed. USE ONLY DEPURECO ORIGINAL FILTER CARTRIDGES! TO MOUNT THE NEW FILTER CARTRIDGES, REVERSE THE STEPS PREVIOUSLY DESCRIBED...
  • Page 40: Replacing The Hepa Filter

    Wear appropriate PPE (dust mask, latex gloves, goggles, etc.). Replace the HEPA filter as follows: • Switch off the machine. • Disconnect the vacuum cleaner from the power supply. M65 H ACD - M100 H ACD • Unlock the “C” hooks on the sides of the head base on the filter chamber. • Place the vacuum's head on the work bench. •...
  • Page 41 HEPA FILTER - OPTIONAL M65 - M100 - M65 JC - M100 JC - M65 TAN JC - M100 TAN JC • Unlock the “C” hooks on the sides of the head base on the filter chamber. • Place the vacuum's head on the work bench. • Unscrew the nut (L) of the HEPA filter. • Remove the filter from the vacuum's head. ALL MODELS ATTENTION! Remove the filter, put it in a plastic bag, close it and dispose of it according to the laws in force for the type of material vacuumed.
  • Page 42 Replace the HEPA filter as follows: • Switch off the machine. • Disconnect the vacuum cleaner from the power supply. HEPA FILTER - OPTIONAL M65 H ACD - M100 H ACD • Unlock the “C” hooks on the sides of the head base on the filter chamber. • Place the vacuum's head on the work bench. •...
  • Page 43 ATTENTION! Remove the filter, put it in a plastic bag, close it and dispose of it according to the laws in force for the type of material vacuumed. USE ONLY DEPURECO ORIGINAL HEPA FILTERS! TO REMOVE THE HEPA FILTER, REVERSE THE STEPS PREVIOUSLY DESCRIBED ATTENTION! FOR SOME MODELS THE HEPA FILTER IS...
  • Page 44: If Something Doesn't Work

    Check the power socket not start for voltage; • Check the socket and power supply cable to make sure they are intact; • Contact the DEPURECO technical assistance service. The red light on or vacuum Clogged filter Shake the filter. If this is not gauge indicates an irregular enough, replace it. depression...
  • Page 45: Maintenance Log

    CITY: POSTCODE: SECTOR TELEPHONE: PERSON IN CHARGE: STAMP: Depureco Industrial Vacuums Srl Company under the direction and coordination of COFISE S.p.A. www.depureco.com tax code- and VAT reg no. Share capital: Via Venezia, 32 - 10088 Volpiano (TO), Italy 02258610357 - €...
  • Page 46 TYPE OF INTERVENTION: INTERVENTION 2: DATE: TECHNICAL ASSISTANCE: TYPE OF INTERVENTION: Depureco Industrial Vacuums Srl Company under the direction and coordination of COFISE S.p.A. Via Venezia, 32 - 10088 Volpiano (TO), Italy www.depureco.com tax code- and VAT reg no. 02258610357 - Share capital: €...
  • Page 47 TYPE OF INTERVENTION: INTERVENTION 4: DATE: TECHNICAL ASSISTANCE: TYPE OF INTERVENTION: Depureco Industrial Vacuums Srl Company under the direction and coordination of COFISE S.p.A. Via Venezia, 32 - 10088 Volpiano (TO), Italy www.depureco.com tax code- and VAT reg no. 02258610357 - Share capital: €...