HP C5658A - SureStore DLT 70e Tape Drive User Manual page 11

Internal/external tape drive
Hide thumbs Also See for C5658A - SureStore DLT 70e Tape Drive:
  • Faq (34 pages)
Table of Contents

Advertisement

Installing Your Internal Drive
Step 1: Check the Drive's SCSI ID
Figure 1.1 SCSI ID settings on internal drives
Figure 1.2 SCSI ID jumper blocks
HP SureStore DLT 40i
HP SureStore DLT 70
i and 80i
Figure 1.3 SCSI ID jumper settings
HP SureStore DLT 70i
and 80i only:
1-6
If you need a different SCSI ID, you must set it by using jumpers on a set
of pins at the side of the drive as shown in figure 1.1.
There should be no jumpers on the block when you receive the drive. This
gives the drive a default SCSI ID of 5.
Side view of drive
The jumper block has five pairs of pins that are used as shown in figure 1.2.
SCSI ID pins (three pairs)
Disable parity. A jumper set across these pins disables parity
checking. Normally you should leave this jumper OFF .
Remote ID present. A jumper across these pins tells the host to
read the SCSI ID from the SCSI ID pins. Place a jumper across
these pins if you want the drive to have an ID other than 5.
SCSI ID pins (four pairs)
Remote ID present. A jumper across these pins tells the host to
read the SCSI ID from the SCSI ID pins. Place a jumper across
these pins if you want the drive to have an ID other than 5.
The SCSI ID pins are used to set the ID as shown in figure 1.3.
(Default)
5
0
8
9
SCSI ID jumper block
1
2
1
1
12
Front panel
3
4
6
13
14
15

Advertisement

Table of Contents
loading

Table of Contents